Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1008 | Sole/Wasser | CTA AG | 13.8 | 2016 | 280 | 4 | 7300.0 | 34564.0 | 2196 | 4.73 | 1240.0 | 6047.0 | 382 | 4.88 | 1045.0 | 5145.0 | 321 | 4.92 | 1039.0 | 5111.0 | 321 | 4.92 | 533.0 | 2659.0 | 159 | 4.99 | 328.0 | 1540.0 | 94 | 4.70 | 70.0 | 196.0 | 11 | 2.80 | 69.0 | 32.0 | 2 | 0.46 | 50.0 | 29.0 | 2 | 0.58 | 116.0 | 440.0 | 27 | 3.79 | 625.0 | 3179.0 | 194 | 5.09 | 930.0 | 4485.0 | 298 | 4.82 | 1255.0 | 5701.0 | 385 | 4.54 | ||||||||||||
1008 | Sole/Wasser | CTA AG | 13.8 | 2015 | 280 | 4 | 7569.7 | 36904.0 | 2299 | 4.88 | 1373.0 | 6581.0 | 420 | 4.79 | 1260.0 | 6000.0 | 388 | 4.76 | 925.0 | 4533.0 | 286 | 4.90 | 620.0 | 3009.0 | 188 | 4.85 | 311.0 | 1481.0 | 90 | 4.76 | 94.5 | 412.0 | 24 | 4.36 | 7.8 | 15.0 | 1 | 1.92 | 26.4 | 21.0 | 1 | 0.80 | 303.0 | 1513.0 | 88 | 4.99 | 726.0 | 3698.0 | 221 | 5.09 | 886.0 | 4361.0 | 273 | 4.92 | 1037.0 | 5280.0 | 319 | 5.09 | ||||||||||||
1008 | Sole/Wasser | CTA AG | 13.8 | 2014 | 280 | 4 | 6309.0 | 31499.0 | 1938 | 4.99 | 1156.0 | 5741.0 | 359 | 4.97 | 941.0 | 4705.0 | 295 | 5.00 | 764.0 | 3864.0 | 239 | 5.06 | 445.0 | 2211.0 | 135 | 4.97 | 332.0 | 1623.0 | 97 | 4.89 | 1.0 | 4.0 | 4.00 | 11.0 | 46.0 | 2 | 4.18 | 52.0 | 216.0 | 13 | 4.15 | 169.0 | 807.0 | 49 | 4.78 | 448.0 | 2300.0 | 135 | 5.13 | 804.0 | 4089.0 | 247 | 5.09 | 1186.0 | 5893.0 | 367 | 4.97 | |||||||||||||
1008 | Sole/Wasser | CTA AG | 13.8 | 2013 | 280 | 4 | 8598.0 | 40427.0 | 2347 | 4.70 | 1608.0 | 7373.0 | 477 | 4.59 | 1599.0 | 7171.0 | 272 | 4.48 | 1392.0 | 6334.0 | 413 | 4.55 | 672.0 | 3103.0 | 196 | 4.62 | 432.0 | 1962.0 | 117 | 4.54 | 145.0 | 581.0 | 34 | 4.01 | 3.0 | 11.0 | 1 | 3.67 | 20.0 | 60.0 | 3 | 3.00 | 219.0 | 1100.0 | 61 | 5.02 | 491.0 | 2494.0 | 145 | 5.08 | 869.0 | 4466.0 | 270 | 5.14 | 1148.0 | 5772.0 | 358 | 5.03 | ||||||||||||
1008 | Sole/Wasser | CTA AG | 13.8 | 2012 | 280 | 2 | 2777.0 | 13927.0 | 876 | 5.02 | 539.0 | 2786.0 | 160 | 5.17 | 867.0 | 4495.0 | 274 | 5.18 | 1371.0 | 6646.0 | 442 | 4.85 |
NR | 1008 |
Username | lollyi |
Einbaujahr der WP | 2012-09-26 |
PLZ des Wohnortes | 72644 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | CTA AG |
modulierend | |
Leistung (0/35) | 13.8 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | x Erdbohrungen a |
Tiefe | 130.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 10.6 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 4.5 |
Heizflaeche | 280 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Mit 100% Wasser betriebene WP mit 3 Erdbohrungen. Einbau in 20 Jahre altes Wohnhaus, Heizölverbrauch war ca. 3800 Liter/Jahr. FBH war vorhanden. Bestandesbau ohne zus. Isolation. Der Strom wird über alle elektrischen Verbraucher inkl. Pumpen und Regelung und elektr. Zusatzheizung gemessen. An kalten Tagen in EG-Wohnung (210qm) wird mit Kaminofen zugeheizt. Ab Jan. 2013 4 Personen ! Mit vorhandener Solaranlage Paradigma Aqua-Paket mit Vakuum-Röhrenkollektoren CPC 45 Star azzurro mit 10qm Fläche,Kombispeicher Titan 600 Pufferinhalt 642 l Wasserinhalt 150 l, (Einsparpotential war bei der Ölheizung ca 700-800 Liter pro Jahr). Permatrade Paket aktiv plus mit aktiv Kalkumwandler mit Sauerstoffaktivierung und permasolvent primus Kalkbehandler, Ecomaster mit Zirkulationssteuerung. Im Mon. Juni, Juli + August Sept. wird gekühlt !!!!!! |