Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2019 | 245 | 5 | 1263.0 | 5226.9 | 4.14 | 570.0 | 2334.5 | 4.10 | 363.0 | 1794.6 | 4.94 | 330.0 | 1097.8 | 3.33 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2018 | 245 | 5 | 2437.0 | 9775.2 | 4.01 | 422.0 | 1656.0 | 3.92 | 638.0 | 2409.0 | 3.78 | 430.0 | 1618.5 | 3.76 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 227.0 | 618.0 | 2.72 | 311.0 | 1540.0 | 4.95 | 403.0 | 1927.7 | 4.78 | |||||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2017 | 245 | 5 | 2670.0 | 9834.0 | 1 | 3.68 | 881.0 | 2809.0 | 3.19 | 400.0 | 1792.0 | 4.48 | 204.0 | 720.0 | 3.53 | 172.0 | 460.0 | 1 | 2.67 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 1.0 | 1.0 | 1.00 | 398.0 | 1736.0 | 4.36 | 609.0 | 2311.0 | 3.79 | |||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2016 | 245 | 6 | 2434.0 | 10045.1 | 4.13 | 481.0 | 1982.2 | 4.12 | 389.0 | 1792.6 | 4.61 | 374.0 | 1371.3 | 3.67 | 208.0 | 867.0 | 4.17 | 400.0 | 1690.0 | 4.23 | 582.0 | 2342.0 | 4.02 | |||||||||||||||||||||||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2015 | 245 | 6 | 2385.0 | 9493.0 | 3.98 | 566.0 | 2193.0 | 3.87 | 604.0 | 2290.0 | 3.79 | 276.0 | 993.0 | 3.60 | 128.0 | 313.0 | 2.45 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 121.0 | 384.0 | 3.17 | 235.0 | 1372.0 | 5.84 | 455.0 | 1948.0 | 4.28 | ||||||||||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2014 | 245 | 6 | 2047.0 | 8733.0 | 4.27 | 488.0 | 2034.0 | 4.17 | 395.0 | 1740.0 | 4.41 | 276.0 | 993.0 | 3.60 | 128.0 | 313.0 | 2.45 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 43.0 | 248.0 | 5.77 | 239.0 | 1371.0 | 5.74 | 478.0 | 2034.0 | 4.26 | ||||||||||||||||||||||||||||||
1067 | Luft/Wasser | Altherma | 7.1 | 2013 | 245 | 7 | 2788.2 | 11175.0 | 678 | 4.01 | 628.0 | 2280.0 | 670 | 3.63 | 628.0 | 2363.0 | 1 | 3.76 | 420.0 | 1710.0 | 1 | 4.07 | 80.2 | 357.0 | 1 | 4.45 | 1.0 | 1.0 | 1 | 1.00 | 1.0 | 1.0 | 1 | 1.00 | 1.0 | 1.0 | 1 | 1.00 | 1.0 | 1.0 | 1 | 1.00 | 1.0 | 1.0 | 1 | 1.00 | 100.0 | 352.0 | 3.52 | 338.0 | 1715.0 | 5.07 | 589.0 | 2393.0 | 4.06 |
NR | 1067 |
Username | tomo62 |
Einbaujahr der WP | 2013-01-12 |
PLZ des Wohnortes | CH-3053 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Altherma |
modulierend | |
Leistung (0/35) | 7.1 kW |
berechneter Primärenergiebedarf | 32.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2080 Watt DB |
elektr. Verbrauch HP gem./DB | 65 Watt |
elektr. Verbrauch WQ P gem./DB | 22 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 19.0 °C |
Mittlere Wärmequellentemperatur | 29.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 245 m² |
Lüftung | zenKWLWR |
Personen | 7 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Minergiestandart in der Schweiz. zusätzlich ein Schwedenofen nach Bedarf. Wärmebedarf laut Annahme aus Erfahrungswerten der früheren Heizung, 25 Watt je m2 beheizbare Fläche.(Beginn Messung 12. Januar 2013) |