Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1111 | Sole/Wasser | Vaillant VWS 141/2 | 13.8 | 2014 | 190 | 2 | 1941.0 | 7164.0 | 3.69 | 336.0 | 1353.0 | 4.03 | 248.0 | 999.0 | 4.03 | 181.0 | 686.0 | 3.79 | 148.0 | 533.0 | 3.60 | 133.0 | 340.0 | 2.56 | 60.0 | 184.0 | 3.07 | 50.0 | 135.0 | 2.70 | 64.0 | 188.0 | 2.94 | 78.0 | 225.0 | 2.88 | 107.0 | 353.0 | 3.30 | 173.0 | 650.0 | 3.76 | 363.0 | 1518.0 | 4.18 | |||||||||||||||||||||||||
1111 | Sole/Wasser | Vaillant VWS 141/2 | 13.8 | 2013 | 190 | 3 | 2465.0 | 8982.0 | 3.64 | 431.0 | 1550.0 | 3.60 | 370.0 | 1300.0 | 3.51 | 364.0 | 1481.0 | 4.07 | 255.0 | 926.0 | 3.63 | 153.0 | 533.0 | 3.48 | 131.0 | 304.0 | 2.32 | 57.0 | 147.0 | 2.58 | 54.0 | 147.0 | 2.72 | 62.0 | 201.0 | 3.24 | 91.0 | 363.0 | 3.99 | 187.0 | 745.0 | 3.98 | 310.0 | 1285.0 | 4.15 | |||||||||||||||||||||||||
1111 | Sole/Wasser | Vaillant VWS 141/2 | 13.8 | 2012 | 190 | 3 | 2876.0 | 9765.0 | 3.40 | 344.0 | 1400.0 | 4.07 | 510.0 | 2185.0 | 4.28 | 364.0 | 1000.0 | 2.75 | 172.0 | 700.0 | 4.07 | 170.0 | 430.0 | 2.53 | 173.0 | 420.0 | 2.43 | 71.0 | 110.0 | 1.55 | 67.0 | 90.0 | 1.34 | 103.0 | 250.0 | 2.43 | 203.0 | 700.0 | 3.45 | 262.0 | 980.0 | 3.74 | 437.0 | 1500.0 | 3.43 |
NR | 1111 |
Username | Taxus |
Einbaujahr der WP | 2010-07-15 |
PLZ des Wohnortes | 37120 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Vaillant VWS 141/2 |
modulierend | |
Leistung (0/35) | 13.8 kW |
berechneter Primärenergiebedarf | 48.1 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 54 °C |
WW Legionellenschaltung | Ja |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | x Erdbohrungen a |
Tiefe | 80.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 9.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 190 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Erdbohrungen 3x 80 m |