Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2023 | 180 | 4 | 2747.0 | 11101.0 | 955 | 4.04 | 521.0 | 2214.0 | 196 | 4.25 | 421.0 | 1735.0 | 153 | 4.12 | 326.0 | 1252.0 | 110 | 3.84 | 278.0 | 1106.0 | 94 | 3.98 | 76.0 | 228.0 | 20 | 3.00 | 16.0 | 39.0 | 2 | 2.44 | 0 | 0 | 0 | 0 | 0 | 0 | 45.0 | 190.0 | 8 | 4.22 | 162.0 | 565.0 | 46 | 3.49 | 446.0 | 1874.0 | 161 | 4.20 | 456.0 | 1898.0 | 165 | 4.16 | ||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2022 | 180 | 4 | 2388.0 | 8862.0 | 694 | 3.81 | 533.0 | 2213.0 | 162 | 4.15 | 338.0 | 1287.0 | 152 | 3.81 | 321.0 | 1167.0 | 70 | 3.64 | 227.0 | 739.0 | 74 | 3.26 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 59.0 | 0 | 0 | 69.0 | 77.0 | 13 | 1.12 | 38.0 | 52.0 | 10 | 1.37 | 310.0 | 1206.0 | 62 | 3.89 | 493.0 | 2121.0 | 151 | 4.30 | ||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2021 | 180 | 4 | 2657.0 | 11099.0 | 857 | 4.18 | 443.0 | 1909.0 | 169 | 4.31 | 444.0 | 1910.0 | 170 | 4.30 | 336.0 | 1326.0 | 98 | 3.95 | 274.0 | 1080.0 | 60 | 3.94 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 101.0 | 289.0 | 24 | 2.86 | 174.0 | 684.0 | 43 | 3.93 | 402.0 | 1807.0 | 131 | 4.50 | 483.0 | 2094.0 | 162 | 4.34 | ||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2020 | 180 | 4 | 2440.0 | 9632.0 | 618 | 3.95 | 514.0 | 2138.0 | 140 | 4.16 | 369.0 | 1534.0 | 125 | 4.16 | 286.0 | 1102.0 | 76 | 3.85 | 78.0 | 154.0 | 4 | 1.97 | 76.0 | 146.0 | 4 | 1.92 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 97.0 | 123.0 | 5 | 1.27 | 221.0 | 906.0 | 52 | 4.10 | 293.0 | 1323.0 | 92 | 4.52 | 506.0 | 2206.0 | 120 | 4.36 | |||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2019 | 180 | 4 | 2689.0 | 10803.0 | 758 | 4.02 | 720.0 | 3105.0 | 252 | 4.31 | 319.0 | 1284.0 | 94 | 4.03 | 295.0 | 1121.0 | 73 | 3.80 | 115.0 | 415.0 | 24 | 3.61 | 113.0 | 332.0 | 21 | 2.94 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 80.0 | 133.0 | 2 | 1.66 | 171.0 | 657.0 | 29 | 3.84 | 440.0 | 1897.0 | 130 | 4.31 | 436.0 | 1859.0 | 133 | 4.26 | |||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2018 | 180 | 4 | 3479.0 | 14509.0 | 1063 | 4.17 | 489.0 | 2093.0 | 61 | 4.28 | 531.0 | 2232.0 | 242 | 4.20 | 518.0 | 2177.0 | 176 | 4.20 | 353.0 | 1370.0 | 92 | 3.88 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 140.0 | 450.0 | 60 | 3.21 | 340.0 | 1400.0 | 130 | 4.12 | 669.0 | 2872.0 | 151 | 4.29 | 439.0 | 1915.0 | 151 | 4.36 | |||||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2017 | 180 | 4 | 2777.0 | 12828.0 | 982 | 4.62 | 522.0 | 2773.0 | 220 | 5.31 | 703.0 | 3491.0 | 286 | 4.97 | 394.0 | 1945.0 | 147 | 4.94 | 253.0 | 1067.0 | 77 | 4.22 | 173.0 | 803.0 | 52 | 4.64 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 148.0 | 428.0 | 27 | 2.89 | 147.0 | 472.0 | 22 | 3.21 | 437.0 | 1849.0 | 151 | 4.23 | ||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2016 | 180 | 4 | 2701.0 | 12151.0 | 1186 | 4.50 | 605.0 | 2972.0 | 265 | 4.91 | 318.0 | 1584.0 | 193 | 4.98 | 299.0 | 1407.0 | 122 | 4.71 | 186.0 | 808.0 | 68 | 4.34 | 61.0 | 197.0 | 16 | 3.23 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 10.0 | 10.0 | 1 | 1.00 | 273.0 | 982.0 | 109 | 3.60 | 427.0 | 1912.0 | 165 | 4.48 | 522.0 | 2279.0 | 247 | 4.37 | |||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2014 | 180 | 4 | 1682.0 | 7888.0 | 480 | 4.69 | 480.6 | 2425.0 | 214 | 5.05 | 440.0 | 1976.0 | 176 | 4.49 | 151.6 | 580.0 | 49 | 3.83 | 112.9 | 491.0 | 41 | 4.35 | 146.9 | 752.0 | 5.12 | 350.0 | 1664.0 | 4.75 | ||||||||||||||||||||||||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2013 | 180 | 4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2012 | 180 | 4 | 2339.5 | 9927.6 | 841 | 4.24 | 513.0 | 2280.0 | 206 | 4.44 | 601.0 | 2556.0 | 241 | 4.25 | 242.0 | 873.0 | 71 | 3.61 | 228.6 | 925.0 | 73 | 4.05 | 24.4 | 53.0 | 8 | 2.17 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 23.0 | 59.2 | 3 | 2.57 | 272.0 | 1111.4 | 79 | 4.09 | 435.5 | 2070.0 | 160 | 4.75 | |||||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2011 | 180 | 3 | 2600.0 | 10507.0 | 950 | 4.04 | 619.0 | 2636.0 | 246 | 4.26 | 452.0 | 1877.0 | 173 | 4.15 | 333.0 | 1136.0 | 149 | 3.41 | 83.0 | 228.0 | 20 | 2.75 | 23.0 | 24.0 | 2 | 1.04 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 180.0 | 646.0 | 47 | 3.59 | 439.0 | 1841.0 | 126 | 4.19 | 471.0 | 2119.0 | 187 | 4.50 | ||||||||||||||||
115 | Sole/Wasser | Junkers STE 90 | 9.2 | 2010 | 180 | 3 | 3424.0 | 13345.0 | 1008 | 3.90 | 859.0 | 2946.0 | 140 | 3.43 | 468.0 | 1786.0 | 144 | 3.82 | 345.0 | 1418.0 | 118 | 4.11 | 164.0 | 660.0 | 39 | 4.02 | 140.0 | 512.0 | 14 | 3.66 | 25.0 | 121.0 | 9 | 4.84 | 0 | 0 | 0 | 0 | 0 | 0 | 94.0 | 332.0 | 25 | 3.53 | 276.0 | 1159.0 | 88 | 4.20 | 375.0 | 1568.0 | 165 | 4.18 | 678.0 | 2843.0 | 266 | 4.19 |
NR | 115 |
Username | Teckbau |
Einbaujahr der WP | 2009-11-01 |
PLZ des Wohnortes | 73265 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Junkers STE 90 |
modulierend | Nein |
Leistung (0/35) | 9.2 kW |
berechneter Primärenergiebedarf | 53.0 kWh/m²/anno |
WW über WP | teil |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 140.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 12.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 8.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Es gibt noch eine 10m² Solarthermie für Heizungsunterstützung. Deswegen sind die Verbrauchswerte im Sommer und in den Übergangszeiten mit Vorsicht zu genießen. |