Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1183 | Sole/Wasser | Alpha-Innotec | 8.9 | 2017 | 240 | 4 | 1608.5 | 6805.1 | 687 | 4.23 | 496.3 | 2201.0 | 224 | 4.43 | 301.9 | 1343.1 | 137 | 4.45 | 239.0 | 1038.8 | 105 | 4.35 | 162.5 | 694.0 | 69 | 4.27 | 96.1 | 359.8 | 36 | 3.74 | 49.2 | 169.5 | 17 | 3.45 | 49.0 | 170.2 | 17 | 3.47 | 52.2 | 180.3 | 18 | 3.45 | 56.4 | 205.0 | 20 | 3.63 | 105.9 | 443.4 | 44 | 4.19 | ||||||||||||||||||||
1183 | Sole/Wasser | Alpha-Innotec | 8.9 | 2016 | 240 | 4 | 2350.9 | 10201.9 | 1016 | 4.34 | 336.0 | 1635.6 | 163 | 4.87 | 301.6 | 1338.3 | 134 | 4.44 | 316.9 | 1380.9 | 139 | 4.36 | 211.8 | 893.9 | 89 | 4.22 | 113.4 | 417.4 | 43 | 3.68 | 74.6 | 259.2 | 26 | 3.47 | 69.5 | 239.4 | 24 | 3.44 | 65.2 | 226.4 | 22 | 3.47 | 66.3 | 229.5 | 23 | 3.46 | 157.5 | 685.2 | 66 | 4.35 | 278.5 | 1269.1 | 125 | 4.56 | 359.6 | 1627.0 | 162 | 4.52 | ||||||||||||
1183 | Sole/Wasser | Alpha-Innotec | 8.9 | 2015 | 240 | 4 | 2368.5 | 10487.9 | 1026 | 4.43 | 443.4 | 2057.1 | 202 | 4.64 | 407.7 | 1868.2 | 186 | 4.58 | 319.9 | 1482.8 | 144 | 4.64 | 167.0 | 750.5 | 74 | 4.49 | 76.8 | 293.2 | 28 | 3.82 | 50.6 | 174.7 | 17 | 3.45 | 45.5 | 155.7 | 16 | 3.42 | 45.5 | 155.7 | 16 | 3.42 | 74.8 | 263.7 | 25 | 3.53 | 187.7 | 827.1 | 79 | 4.41 | 242.7 | 1081.2 | 105 | 4.45 | 306.9 | 1378.0 | 134 | 4.49 | ||||||||||||
1183 | Sole/Wasser | Alpha-Innotec | 8.9 | 2014 | 240 | 4 | 2326.5 | 10331.9 | 1002 | 4.44 | 393.8 | 1833.6 | 179 | 4.66 | 384.6 | 1761.4 | 173 | 4.58 | 265.5 | 1193.5 | 117 | 4.50 | 116.2 | 465.8 | 43 | 4.01 | 121.0 | 486.3 | 48 | 4.02 | 71.9 | 255.3 | 25 | 3.55 | 64.9 | 231.7 | 23 | 3.57 | 64.9 | 231.7 | 23 | 3.57 | 67.5 | 253.7 | 25 | 3.76 | 109.1 | 470.0 | 44 | 4.31 | 268.2 | 1271.2 | 120 | 4.74 | 398.9 | 1877.7 | 182 | 4.71 | ||||||||||||
1183 | Sole/Wasser | Alpha-Innotec | 8.9 | 2013 | 240 | 4 | 2959.4 | 13093.2 | 1285 | 4.42 | 505.0 | 2254.0 | 222 | 4.46 | 512.0 | 2253.0 | 226 | 4.40 | 479.0 | 2104.0 | 210 | 4.39 | 261.0 | 1122.0 | 110 | 4.30 | 150.0 | 672.0 | 65 | 4.48 | 75.0 | 271.0 | 27 | 3.61 | 45.8 | 165.2 | 16 | 3.61 | 46.5 | 167.3 | 16 | 3.60 | 55.8 | 211.6 | 20 | 3.79 | 115.0 | 510.6 | 48 | 4.44 | 302.8 | 1444.6 | 138 | 4.77 | 411.5 | 1917.9 | 187 | 4.66 |
NR | 1183 |
Username | sg1971 |
Einbaujahr der WP | 2011-11-24 |
PLZ des Wohnortes | 67259 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha-Innotec |
modulierend | |
Leistung (0/35) | 8.9 kW |
berechneter Primärenergiebedarf | 43.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 70.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1900 Watt DB |
elektr. Verbrauch HP gem./DB | 65 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 240 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |