Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1223 | Wasser/Wasser | IDM Terra 8S/W-HGL | 8.2 | 2015 | 323 | 3 | 4358.0 | 14498.0 | 1405 | 3.33 | 890.0 | 3097.0 | 307 | 3.48 | 872.0 | 3014.0 | 299 | 3.46 | 683.0 | 2288.0 | 230 | 3.35 | 501.0 | 1643.0 | 163 | 3.28 | 312.0 | 995.0 | 94 | 3.19 | 152.0 | 447.0 | 41 | 2.94 | 151.0 | 416.0 | 37 | 2.75 | 168.0 | 445.0 | 39 | 2.65 | 163.0 | 528.0 | 45 | 3.24 | 466.0 | 1625.0 | 150 | 3.49 | ||||||||||||||||||||
1223 | Wasser/Wasser | IDM Terra 8S/W-HGL | 8.2 | 2014 | 323 | 3 | 5985.0 | 18411.0 | 1634 | 3.08 | 1126.0 | 1000.0 | 0.89 | 599.0 | 2083.0 | 209 | 3.48 | 687.0 | 3756.0 | 238 | 5.47 | 430.0 | 1571.0 | 91 | 3.65 | 332.0 | 1098.0 | 159 | 3.31 | 188.0 | 560.0 | 56 | 2.98 | 180.0 | 511.0 | 53 | 2.84 | 190.0 | 545.0 | 57 | 2.87 | 224.0 | 641.0 | 68 | 2.86 | 439.0 | 1368.0 | 150 | 3.12 | 766.0 | 2366.0 | 271 | 3.09 | 824.0 | 2912.0 | 282 | 3.53 | |||||||||||||
1223 | Wasser/Wasser | IDM Terra 8S/W-HGL | 8.2 | 2013 | 323 | 3 | 5277.0 | 2860.0 | 1774 | 3.57 | 940.0 | 313 | 863.0 | 287 | 905.0 | 301 | 535.0 | 178 | 389.0 | 129 | 232.0 | 77 | 202.0 | 67 | 166.0 | 55 | 243.0 | 81 | 802.0 | 2860.0 | 286 | 3.57 | ||||||||||||||||||||||||||||||||||||||
1223 | Wasser/Wasser | IDM Terra 8S/W-HGL | 8.2 | 2012 | 323 | 3 | 5424.0 | 1804 | 722.0 | 240 | 840.0 | 280 | 650.0 | 216 | 456.0 | 152 | 201.0 | 67 | 185.0 | 61 | 207.0 | 69 | 160.0 | 53 | 190.0 | 63 | 562.0 | 187 | 485.0 | 161 | 766.0 | 255 |
NR | 1223 |
Username | rolandfeil |
Einbaujahr der WP | 2010-07-01 |
PLZ des Wohnortes | 94559 |
Bauart | Wasser/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | IDM Terra 8S/W-HGL |
modulierend | |
Leistung (0/35) | 8.2 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Förder- und Schluckbrunnen |
Tiefe | 8.5 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1900 Watt DB |
elektr. Verbrauch HP gem./DB | 150 Watt |
elektr. Verbrauch WQ P gem./DB | 800 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 9.5 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 323 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |