Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2019 | 175 | 3 | 546.1 | 2495.1 | 730 | 4.57 | 546.1 | 2495.1 | 730 | 4.57 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2018 | 175 | 3 | 2975.1 | 12283.5 | 2517 | 4.13 | 609.6 | 2614.0 | 275 | 4.29 | 608.9 | 2499.1 | 272 | 4.10 | 569.6 | 2324.8 | 252 | 4.08 | 148.9 | 493.5 | 49 | 3.31 | 52.7 | 83.9 | 8 | 1.59 | 44.9 | 0.1 | 1 | 55.9 | 0.1 | 1 | 56.8 | 0.1 | 1 | 64.3 | 103.0 | 34 | 1.60 | 115.1 | 670.2 | 311 | 5.82 | 227.5 | 1331.8 | 573 | 5.85 | 420.9 | 2162.9 | 740 | 5.14 | |||||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2017 | 175 | 3 | 3515.7 | 13362.1 | 1376 | 3.80 | 803.0 | 3166.1 | 343 | 3.94 | 584.9 | 2344.2 | 258 | 4.01 | 381.9 | 1436.9 | 156 | 3.76 | 191.4 | 693.5 | 69 | 3.62 | 113.4 | 258.6 | 27 | 2.28 | 45.5 | 0.1 | 1 | 46.6 | 0.1 | 1 | 47.1 | 0.1 | 1 | 41.6 | 0.1 | 1 | 175.4 | 686.1 | 58 | 3.91 | 478.8 | 2130.1 | 197 | 4.45 | 606.1 | 2646.2 | 264 | 4.37 | ||||||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2016 | 175 | 3 | 3052.9 | 11119.6 | 1129 | 3.64 | 627.5 | 2410.3 | 257 | 3.84 | 472.6 | 1834.1 | 198 | 3.88 | 422.7 | 1621.7 | 175 | 3.84 | 83.0 | 170.1 | 16 | 2.05 | 68.3 | 88.5 | 9 | 1.30 | 47.4 | 1.0 | 1 | 0.02 | 47.7 | 1.0 | 1 | 0.02 | 47.8 | 1.0 | 1 | 0.02 | 45.1 | 1.0 | 1 | 0.02 | 230.9 | 977.5 | 83 | 4.23 | 398.7 | 1731.9 | 158 | 4.34 | 561.2 | 2281.5 | 229 | 4.07 | ||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2015 | 175 | 3 | 2801.6 | 10250.5 | 1014 | 3.66 | 519.8 | 2053.8 | 210 | 3.95 | 499.0 | 1931.4 | 203 | 3.87 | 373.0 | 1382.2 | 145 | 3.71 | 162.7 | 521.6 | 53 | 3.21 | 67.4 | 86.9 | 7 | 1.29 | 50.3 | 12.2 | 1 | 0.24 | 49.3 | 0.1 | 47.8 | 0.1 | 76.4 | 185.7 | 15 | 2.43 | 200.4 | 877.9 | 73 | 4.38 | 268.2 | 1154.3 | 104 | 4.30 | 487.3 | 2044.3 | 203 | 4.20 | ||||||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2014 | 175 | 3 | 3106.7 | 11032.9 | 1123 | 3.55 | 641.0 | 2302.0 | 256 | 3.59 | 526.0 | 1961.0 | 220 | 3.73 | 347.0 | 1241.0 | 136 | 3.58 | 198.0 | 696.0 | 71 | 3.52 | 142.0 | 452.0 | 39 | 3.18 | 51.0 | 15.0 | 1 | 0.29 | 45.0 | 0.1 | 47.0 | 0.1 | 44.0 | 0.1 | 161.1 | 222.9 | 48 | 1.38 | 367.0 | 1937.0 | 140 | 5.28 | 537.6 | 2205.7 | 212 | 4.10 | ||||||||||||||||||
1250 | Sole/Wasser | Buderus Logatherm WPS9 | 9.2 | 2013 | 175 | 3 | 1104.5 | 4212.0 | 435 | 3.81 | 472.0 | 1907.0 | 182 | 4.04 | 632.5 | 2305.0 | 253 | 3.64 |
NR | 1250 |
Username | hwassmann_alt |
Einbaujahr der WP | 2012-05-20 |
PLZ des Wohnortes | A-8570 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Tri |
Hersteller Typ | Buderus Logatherm WPS9 |
modulierend | |
Leistung (0/35) | 9.2 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.2 m |
Fläche | 300 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2000 Watt DB |
elektr. Verbrauch HP gem./DB | 100 Watt |
elektr. Verbrauch WQ P gem./DB | 165 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 175 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Ja,ca 60m Graben (100/100/200m), Ergänzumg zu einem 500m (5x100m) Flächenkollektor, Zusammengeschaltet zu 3x300m. |
Bemerkungen | Haus ca. 35 Jahre alt, Vollwärmeschutz Solarthermie für WW und Heizungsunterstützung Kachelkamin mit Wärmetauscher 1000 l Pufferspeicher Solepumpe auf Effizienzpumpe umgerüstet in 7/2014 (Wilo Stratos Para 25/1-11). Heizkreispumpe auf Effizienzpumpe umgerüstet in 05/2015 (Wilo Yonos Pico 25/1-6. Im Sommer läuft nur die Solaranlage für WW. Der Stromverbrauch wird jedoch mitgeloggt mit der Heizung. Austausch Wärmepumpe von Buderus auf KNV 1155 in 06/2018 Seit 06/2018 Umstellung WP auf KNV 1155-6 |