Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1304 | Sole/Wasser | Viessmann Vitocal 333-G | 6.2 | 2017 | 197 | 4 | 2556.6 | 12888.1 | 1511 | 5.04 | 467.8 | 2190.1 | 268 | 4.68 | 337.9 | 1724.9 | 208 | 5.10 | 269.7 | 1405.4 | 164 | 5.21 | 236.9 | 1228.3 | 142 | 5.18 | 94.7 | 505.3 | 56 | 5.34 | 28.4 | 117.3 | 13 | 4.13 | 26.5 | 103.7 | 11 | 3.91 | 29.1 | 117.8 | 12 | 4.05 | 112.6 | 612.4 | 66 | 5.44 | 163.2 | 950.3 | 104 | 5.82 | 366.8 | 1856.8 | 218 | 5.06 | 423.0 | 2075.8 | 249 | 4.91 | ||||||||||||
1304 | Sole/Wasser | Viessmann Vitocal 333-G | 6.2 | 2016 | 197 | 4 | 2635.4 | 13407.1 | 1564 | 5.09 | 367.8 | 1823.9 | 218 | 4.96 | 371.8 | 1875.0 | 224 | 5.04 | 330.2 | 1700.7 | 201 | 5.15 | 248.2 | 1366.3 | 161 | 5.50 | 114.3 | 606.9 | 66 | 5.31 | 44.0 | 213.3 | 23 | 4.85 | 36.3 | 166.7 | 16 | 4.59 | 33.2 | 144.1 | 15 | 4.34 | 73.9 | 394.5 | 41 | 5.34 | 250.6 | 1382.5 | 156 | 5.52 | 376.5 | 1891.0 | 218 | 5.02 | 388.6 | 1842.2 | 225 | 4.74 | ||||||||||||
1304 | Sole/Wasser | Viessmann Vitocal 333-G | 6.2 | 2015 | 197 | 4 | 2388.0 | 12366.8 | 1437 | 5.18 | 433.0 | 2168.0 | 263 | 5.01 | 394.6 | 1956.1 | 240 | 4.96 | 333.1 | 1746.7 | 208 | 5.24 | 172.9 | 923.2 | 106 | 5.34 | 114.9 | 624.8 | 68 | 5.44 | 41.8 | 203.2 | 22 | 4.86 | 26.7 | 113.4 | 9 | 4.25 | 35.1 | 147.4 | 12 | 4.20 | 82.4 | 462.5 | 51 | 5.61 | 210.1 | 1159.9 | 129 | 5.52 | 270.9 | 1411.3 | 163 | 5.21 | 272.5 | 1450.3 | 166 | 5.32 | ||||||||||||
1304 | Sole/Wasser | Viessmann Vitocal 333-G | 6.2 | 2014 | 197 | 4 | 2025.5 | 10557.7 | 1220 | 5.21 | 436.7 | 2232.5 | 267 | 5.11 | 350.4 | 1829.0 | 219 | 5.22 | 216.9 | 1164.8 | 135 | 5.37 | 88.3 | 484.1 | 53 | 5.48 | 71.1 | 380.8 | 41 | 5.36 | 27.8 | 116.6 | 12 | 4.19 | 27.3 | 112.5 | 10 | 4.12 | 30.4 | 125.5 | 13 | 4.13 | 32.7 | 144.4 | 15 | 4.42 | 95.0 | 534.0 | 56 | 5.62 | 231.4 | 1300.7 | 145 | 5.62 | 417.5 | 2132.8 | 254 | 5.11 | ||||||||||||
1304 | Sole/Wasser | Viessmann Vitocal 333-G | 6.2 | 2013 | 197 | 3 | 3050.0 | 14931.0 | 1761 | 4.90 | 647.0 | 2931.0 | 356 | 4.53 | 506.0 | 2309.0 | 282 | 4.56 | 456.0 | 2157.0 | 262 | 4.73 | 249.0 | 1267.0 | 150 | 5.09 | 150.0 | 806.0 | 88 | 5.37 | 51.0 | 231.0 | 24 | 4.53 | 33.0 | 119.0 | 12 | 3.61 | 35.0 | 130.0 | 14 | 3.71 | 84.0 | 431.0 | 46 | 5.13 | 153.0 | 806.0 | 87 | 5.27 | 331.0 | 1866.0 | 218 | 5.64 | 355.0 | 1878.0 | 222 | 5.29 |
NR | 1304 |
Username | Oma0891 |
Einbaujahr der WP | 2012-12-30 |
PLZ des Wohnortes | 54649 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 333-G |
modulierend | |
Leistung (0/35) | 6.2 kW |
berechneter Primärenergiebedarf | 55.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 95.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 2.8 °C |
Heizung max. Vorlauf Temp. | 28.0 °C |
Spreizung Heizkr. | 0.5 |
Heizflaeche | 197 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |