Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
139 | Sole/Wasser | Stiebel Eltron | 7.8 | 2012 | 148 | 4 | 2195.0 | 9162.0 | 4.17 | 450.0 | 1909.0 | 4.24 | 506.0 | 2089.0 | 4.13 | 303.0 | 1249.0 | 4.12 | 269.0 | 1145.0 | 4.26 | 127.0 | 530.0 | 4.17 | 111.0 | 456.0 | 4.11 | 57.0 | 232.0 | 4.07 | 53.0 | 199.0 | 3.75 | 110.0 | 458.0 | 4.16 | 209.0 | 895.0 | 4.28 | |||||||||||||||||||||||||||||||
139 | Sole/Wasser | Stiebel Eltron | 7.8 | 2011 | 148 | 3 | 2720.0 | 11611.0 | 4.27 | 490.0 | 2116.0 | 4.32 | 409.0 | 1748.0 | 4.27 | 341.0 | 1455.0 | 4.27 | 181.0 | 769.0 | 4.25 | 112.0 | 469.0 | 4.19 | 78.0 | 287.0 | 3.68 | 54.0 | 233.0 | 4.31 | 62.0 | 248.0 | 4.00 | 106.0 | 458.0 | 4.32 | 168.0 | 708.0 | 4.21 | 319.0 | 1367.0 | 4.29 | 400.0 | 1753.0 | 4.38 | |||||||||||||||||||||||||
139 | Sole/Wasser | Stiebel Eltron | 7.8 | 2010 | 148 | 2 | 3494.0 | 14283.8 | 4.09 | 712.0 | 2707.8 | 3.80 | 536.0 | 2198.0 | 4.10 | 375.0 | 1507.0 | 4.02 | 227.0 | 865.0 | 3.81 | 217.0 | 843.0 | 3.88 | 88.0 | 331.0 | 3.76 | 33.0 | 143.0 | 4.33 | 59.0 | 236.0 | 4.00 | 147.0 | 589.0 | 4.01 | 176.0 | 780.0 | 4.43 | 351.0 | 1590.0 | 4.53 | 573.0 | 2494.0 | 4.35 | |||||||||||||||||||||||||
139 | Sole/Wasser | Stiebel Eltron | 7.8 | 2009 | 148 | 1574.0 | 6218.0 | 3.95 | 69.0 | 265.0 | 3.84 | 84.0 | 297.0 | 3.54 | 107.0 | 439.0 | 4.10 | 280.0 | 1244.0 | 4.44 | 420.0 | 1623.0 | 3.86 | 614.0 | 2350.0 | 3.83 |
NR | 139 |
Username | TOBZEN |
Einbaujahr der WP | 2009-06-06 |
PLZ des Wohnortes | 23816 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Stiebel Eltron |
modulierend | |
Leistung (0/35) | 7.8 kW |
berechneter Primärenergiebedarf | 58.5 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 60.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 0.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 148 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |