Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
145 | sonstige | Heliotherm HP08E-M-WEB/CO² | 9.8 | 2012 | 237 | 2 | 3498.0 | 15610.0 | 3032 | 4.46 | 612.0 | 3010.0 | 540 | 4.92 | 663.0 | 3260.0 | 500 | 4.92 | 335.0 | 1740.0 | 368 | 5.19 | 299.0 | 1570.0 | 278 | 5.25 | 299.0 | 1570.0 | 278 | 5.25 | 117.0 | 580.0 | 28 | 4.96 | 60.0 | 70.0 | 39 | 1.17 | 290.0 | 61.0 | 270 | 0.21 | 823.0 | 3749.0 | 731 | 4.56 | ||||||||||||||||||||||||
145 | sonstige | Heliotherm HP08E-M-WEB/CO² | 9.8 | 2011 | 237 | 2 | 3220.0 | 14410.0 | 2377 | 4.48 | 691.0 | 3140.0 | 385 | 4.54 | 567.0 | 2600.0 | 385 | 4.59 | 413.0 | 1910.0 | 337 | 4.62 | 169.0 | 780.0 | 206 | 4.62 | 86.0 | 290.0 | 25 | 3.37 | 54.0 | 180.0 | 33 | 3.33 | 37.0 | 199.0 | 29 | 5.38 | 55.0 | 211.0 | 34 | 3.84 | 50.0 | 190.0 | 33 | 3.80 | 181.0 | 480.0 | 67 | 2.65 | 366.0 | 1750.0 | 373 | 4.78 | 551.0 | 2680.0 | 470 | 4.86 | ||||||||||||
145 | sonstige | Heliotherm HP08E-M-WEB/CO² | 9.8 | 2010 | 237 | 2 | 4650.0 | 21460.0 | 5767 | 4.62 | 898.0 | 3920.0 | 2783 | 4.37 | 681.0 | 2970.0 | 523 | 4.36 | 517.0 | 2630.0 | 420 | 5.09 | 258.0 | 1240.0 | 227 | 4.81 | 224.0 | 1110.0 | 187 | 4.96 | 87.0 | 390.0 | 61 | 4.48 | 47.0 | 170.0 | 26 | 3.62 | 71.0 | 290.0 | 45 | 4.08 | 151.0 | 740.0 | 124 | 4.90 | 294.0 | 1500.0 | 250 | 5.10 | 492.0 | 2370.0 | 408 | 4.82 | 930.0 | 4130.0 | 713 | 4.44 | ||||||||||||
145 | sonstige | Heliotherm HP08E-M-WEB/CO² | 9.8 | 2009 | 237 | 2 | 3440.1 | 13727.0 | 2142 | 3.99 | 1855.0 | 6397.0 | 3.45 | 121.0 | 453.0 | 3.74 | 38.0 | 134.0 | 3.53 | 64.0 | 223.0 | 1007 | 3.48 | 64.0 | 150.0 | 39 | 2.34 | 305.0 | 1660.0 | 216 | 5.44 | 491.0 | 2430.0 | 399 | 4.95 | 502.1 | 2280.0 | 481 | 4.54 |
NR | 145 |
Username | BIER |
Einbaujahr der WP | 2009-02-14 |
PLZ des Wohnortes | 40883 |
Bauart | sonstige |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Heliotherm HP08E-M-WEB/CO² |
modulierend | |
Leistung (0/35) | 9.8 kW |
berechneter Primärenergiebedarf | 21.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | CO2 Erdsonde |
Tiefe | 100.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 28.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 237 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | sonstige = CO² modulierend |