Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2018 | 196 | 4 | 2875.6 | 10076.6 | 917 | 3.50 | 795.5 | 3047.8 | 253 | 3.83 | 984.7 | 3338.6 | 317 | 3.39 | 848.1 | 2834.7 | 271 | 3.34 | 247.3 | 855.5 | 76 | 3.46 | ||||||||||||||||||||||||||||||||||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2017 | 196 | 4 | 5349.5 | 20591.6 | 1691 | 3.85 | 1287.3 | 4393.3 | 417 | 3.41 | 721.7 | 2803.4 | 232 | 3.88 | 535.4 | 2180.4 | 169 | 4.07 | 446.3 | 1789.0 | 141 | 4.01 | 153.1 | 669.6 | 43 | 4.37 | 40.4 | 183.8 | 11 | 4.55 | 49.0 | 222.7 | 12 | 4.54 | 19.6 | 88.8 | 5 | 4.53 | 205.2 | 910.4 | 62 | 4.44 | 352.1 | 1530.1 | 109 | 4.35 | 716.4 | 2782.1 | 227 | 3.88 | 823.0 | 3038.0 | 263 | 3.69 | ||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2016 | 196 | 4 | 5111.3 | 20282.9 | 1605 | 3.97 | 829.4 | 3156.0 | 264 | 3.81 | 677.0 | 2669.6 | 216 | 3.94 | 696.6 | 2740.5 | 223 | 3.93 | 389.2 | 1634.4 | 122 | 4.20 | 192.8 | 845.6 | 58 | 4.39 | 60.9 | 283.4 | 14 | 4.65 | 68.4 | 316.9 | 18 | 4.63 | 24.2 | 113.9 | 6 | 4.71 | 100.0 | 452.4 | 28 | 4.52 | 469.2 | 2000.9 | 145 | 4.26 | 693.9 | 2712.7 | 219 | 3.91 | 909.7 | 3356.6 | 292 | 3.69 | ||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2015 | 196 | 4 | 5128.0 | 19521.7 | 1618 | 3.81 | 912.3 | 3108.5 | 293 | 3.41 | 919.0 | 2977.0 | 298 | 3.24 | 703.3 | 2589.0 | 226 | 3.68 | 417.8 | 1826.3 | 128 | 4.37 | 180.3 | 789.0 | 54 | 4.38 | 50.5 | 294.6 | 16 | 5.83 | 51.1 | 222.2 | 12 | 4.35 | 24.1 | 110.0 | 6 | 4.56 | 155.6 | 693.8 | 47 | 4.46 | 442.1 | 1846.0 | 136 | 4.18 | 543.2 | 2174.8 | 171 | 4.00 | 728.7 | 2890.5 | 231 | 3.97 | ||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2014 | 196 | 4 | 5043.0 | 16892.8 | 1583 | 3.35 | 980.5 | 1846.0 | 313 | 1.88 | 732.9 | 2567.3 | 234 | 3.50 | 594.9 | 2147.8 | 189 | 3.61 | 354.0 | 1354.2 | 111 | 3.83 | 317.9 | 1241.2 | 98 | 3.90 | 86.5 | 296.1 | 22 | 3.42 | 79.3 | 269.1 | 20 | 3.39 | 91.3 | 332.4 | 25 | 3.64 | 150.8 | 634.9 | 47 | 4.21 | 289.4 | 1195.7 | 88 | 4.13 | 686.1 | 2596.2 | 218 | 3.78 | 679.4 | 2411.9 | 218 | 3.55 | ||||||||||||
1495 | Luft/Wasser | Novelan LIC10e | 10.0 | 2013 | 196 | 4 | 4420.4 | 11323.8 | 951 | 3.35 | 698.4 | 2233.6 | 3.20 | 499.4 | 1762.1 | 3.53 | 289.1 | 1035.1 | 80 | 3.58 | 102.7 | 344.8 | 25 | 3.36 | 73.5 | 257.8 | 19 | 3.51 | 307.2 | 1120.5 | 85 | 3.65 | 442.3 | 1569.9 | 127 | 3.55 | 963.2 | 3000.0 | 286 | 3.11 | 1044.6 | 329 |
NR | 1495 |
Username | Der Erwin |
Einbaujahr der WP | 2012-12-20 |
PLZ des Wohnortes | 81247 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Novelan LIC10e |
modulierend | |
Leistung (0/35) | 10.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2900 Watt DB |
elektr. Verbrauch HP gem./DB | 70 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 6.0 |
Heizflaeche | 196 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Sehr offene Bauweise, viele große Glasflächen WMZ defekt von Dez.-Jan. 2013, daher unplausible Werte. Ab 11/2017 WMZ erneut mit unplausiblen Anzeigewerten, daher Angaben zur Wärmemenge und Arbeitszahl nicht realistisch (beides zu gering) |