Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1623 | Luft/Wasser | Nibe F2030-7 & VVM320 | 7.0 | 2019 | 150 | 2 | 1158.0 | 2588.0 | 422 | 2.23 | 460.0 | 1066.0 | 184 | 2.32 | 349.0 | 761.0 | 119 | 2.18 | 349.0 | 761.0 | 119 | 2.18 | ||||||||||||||||||||||||||||||||||||||||||||||||
1623 | Luft/Wasser | Nibe F2030-7 & VVM320 | 7.0 | 2018 | 150 | 2 | 3825.0 | 7297.0 | 1112 | 1.91 | 504.0 | 1147.0 | 186 | 2.28 | 443.0 | 909.0 | 164 | 2.05 | 437.0 | 876.0 | 146 | 2.00 | 255.0 | 487.0 | 72 | 1.91 | 250.0 | 418.0 | 55 | 1.67 | 210.0 | 310.0 | 33 | 1.48 | 260.0 | 350.0 | 40 | 1.35 | 232.0 | 341.0 | 43 | 1.47 | 280.5 | 451.5 | 62 | 1.61 | 280.5 | 451.5 | 62 | 1.61 | 297.0 | 649.0 | 104 | 2.19 | 376.0 | 907.0 | 145 | 2.41 | ||||||||||||
1623 | Luft/Wasser | Nibe F2030-7 & VVM320 | 7.0 | 2017 | 150 | 2 | 3735.0 | 8337.0 | 1281 | 2.23 | 496.0 | 1294.0 | 244 | 2.61 | 379.0 | 996.0 | 166 | 2.63 | 296.0 | 719.0 | 110 | 2.43 | 272.0 | 624.0 | 98 | 2.29 | 241.0 | 503.0 | 75 | 2.09 | 202.0 | 288.0 | 37 | 1.43 | 235.0 | 395.0 | 51 | 1.68 | 230.0 | 396.0 | 49 | 1.72 | 227.0 | 379.0 | 50 | 1.67 | 293.0 | 587.0 | 85 | 2.00 | 383.0 | 947.0 | 135 | 2.47 | 481.0 | 1209.0 | 181 | 2.51 | ||||||||||||
1623 | Luft/Wasser | Nibe F2030-7 & VVM320 | 7.0 | 2016 | 150 | 2 | 3341.0 | 8506.0 | 1426 | 2.55 | 425.0 | 1210.0 | 223 | 2.85 | 397.0 | 1094.0 | 194 | 2.76 | 352.0 | 958.0 | 161 | 2.72 | 218.0 | 481.0 | 78 | 2.21 | 179.0 | 398.0 | 61 | 2.22 | 109.0 | 176.0 | 27 | 1.61 | 162.0 | 333.0 | 51 | 2.06 | 173.0 | 366.0 | 55 | 2.12 | 171.0 | 367.0 | 56 | 2.15 | 264.0 | 657.0 | 101 | 2.49 | 417.0 | 1139.0 | 196 | 2.73 | 474.0 | 1327.0 | 223 | 2.80 | ||||||||||||
1623 | Luft/Wasser | Nibe F2030-7 & VVM320 | 7.0 | 2015 | 150 | 2 | 2083.0 | 3872.5 | 555 | 2.47 | 252.0 | 261.0 | 190.0 | 415.0 | 2.18 | 169.0 | 381.0 | 55 | 2.25 | 165.0 | 348.5 | 52 | 2.11 | 204.0 | 448.0 | 73 | 2.20 | 268.0 | 665.0 | 107 | 2.48 | 289.0 | 781.0 | 132 | 2.70 | 285.0 | 834.0 | 136 | 2.93 |
NR | 1623 |
Username | endverbraucher |
Einbaujahr der WP | 2015-04-01 |
PLZ des Wohnortes | 33803 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Nibe F2030-7 & VVM320 |
modulierend | |
Leistung (0/35) | 7.0 kW |
berechneter Primärenergiebedarf | 10.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 55 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 150 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Neubau 2015 Viebrockhaus KFW40/"3L Haus" |