Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
30 | Luft/Wasser | Dimplex La 11 as | 8.8 | 2012 | 190 | 4 | 4510.0 | * | 1660.0 | 1953.0 | 897.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
30 | Luft/Wasser | Dimplex La 11 as | 8.8 | 2011 | 190 | 4 | 7070.0 | * | 1685.0 | 1247.0 | 1043.0 | 445.0 | 98.0 | 33.0 | 48.0 | 150.0 | 38.0 | 195.0 | 981.0 | 1107.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
30 | Luft/Wasser | Dimplex La 11 as | 8.8 | 2010 | 190 | 4 | 9465.0 | * | 1379.0 | 1161.0 | 995.0 | 742.0 | 415.0 | 60.0 | 81.0 | 109.0 | 253.0 | 886.0 | 1176.0 | 2208.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
30 | Luft/Wasser | Dimplex La 11 as | 8.8 | 2009 | 190 | 4 | 4598.0 | * | 1211.0 | 671.0 | 602.0 | 152.0 | 25.0 | 34.0 | 21.0 | 15.0 | 38.0 | 400.0 | 449.0 | 980.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
30 | Luft/Wasser | Dimplex La 11 as | 8.8 | 2008 | 190 | 4 | 4664.0 | * | 711.0 | 716.0 | 686.0 | 476.0 | 44.0 | 14.0 | 19.0 | 28.0 | 98.0 | 368.0 | 604.0 | 900.0 |
NR | 30 |
Username | Taller |
Einbaujahr der WP | 2007-05-02 |
PLZ des Wohnortes | 32689 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Tri |
Hersteller Typ | Dimplex La 11 as |
modulierend | |
Leistung (0/35) | 8.8 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 190 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Ölheizung und Solar seid Neubau 2001 Wp und Solar seid 2007 Wp und Solar und Holzofen 5kw Wasser 5kw Luft seid 01.2011 alles in 1 Pufferspeicher funktioniert perfekt |