Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
333 | Luft/Wasser | Remko CMT 100 | 8.6 | 2014 | 179 | 3 | 3164.8 | 9165.0* | 1843 | 2.90 | 618.0 | 1428.0 | 217 | 2.65 | 412.0 | 1062.0 | 189 | 3.09 | 404.0 | 917.0 | 284 | 2.79 | 232.8 | 502.0 | 151 | 3.06 | 149.0 | 250.0 | 147 | 3.09 | 83.0 | 77.0 | 60 | 3.46 | 83.0 | 33.0 | 2.93 | 89.0 | 50.0 | 2.92 | 88.0 | 63.0 | 59 | 3.10 | 158.0 | 304.0 | 130 | 3.25 | 278.0 | 615.0 | 206 | 2.97 | 570.0 | 1344.0 | 400 | 2.73 | ||||||||||||||
333 | Luft/Wasser | Remko CMT 100 | 8.6 | 2013 | 179 | 3 | 3830.0 | 10219.0* | 2325 | 2.72 | 651.0 | 1439.0 | 397 | 2.53 | 595.0 | 1288.0 | 393 | 2.52 | 646.0 | 1330.0 | 401 | 2.38 | 356.0 | 765.0 | 238 | 2.74 | 192.0 | 382.0 | 124 | 3.08 | 104.0 | 79.0 | 49 | 2.78 | 75.0 | 7.0 | 23 | 2.89 | 70.0 | 19 | 137.0 | 228.0 | 75 | 3.20 | 163.0 | 329.0 | 142 | 3.31 | 415.0 | 968.0 | 204 | 2.84 | 426.0 | 1094.0 | 260 | 3.06 | ||||||||||||||
333 | Luft/Wasser | Remko CMT 100 | 8.6 | 2012 | 179 | 3 | 3483.4 | 10234.0* | 2389 | 2.94 | 555.0 | 1416.0 | 399 | 2.93 | 782.9 | 1641.0 | 451 | 2.36 | 322.0 | 853.0 | 245 | 3.30 | 278.0 | 744.0 | 222 | 3.43 | 123.0 | 183.0 | 72 | 3.20 | 76.0 | 64.0 | 69 | 3.61 | 82.0 | 15.0 | 34 | 2.74 | 72.0 | 15.0 | 30 | 3.13 | 95.8 | 107.0 | 100 | 3.31 | 281.0 | 651.0 | 200 | 3.06 | 324.7 | 840.0 | 234 | 3.23 | 491.0 | 1185.0 | 333 | 2.84 | ||||||||||||
333 | Luft/Wasser | Remko CMT 100 | 8.6 | 2011 | 179 | 2.5 | 3305.3 | 8397.0* | 912 | 2.66 | 571.0 | 1307.0 | 2.60 | 588.0 | 1210.0 | 2.36 | 446.0 | 942.0 | 2.50 | 204.0 | 410.0 | 107 | 2.87 | 154.0 | 205.0 | 69 | 2.47 | 73.0 | 19 | 78.0 | 18 | 71.0 | 4.0 | 17 | 2.52 | 84.0 | 79.0 | 34 | 3.02 | 213.0 | 451.0 | 117 | 2.94 | 402.3 | 834.0 | 198 | 2.51 | 421.0 | 1205.0 | 333 | 3.28 | |||||||||||||||||||
333 | Luft/Wasser | Remko CMT 100 | 8.6 | 2010 | 179 | 2 | 4327.9 | 9828.0* | 869 | 2.27 | 902.0 | 1471.0 | 1.79 | 600.0 | 1074.0 | 2.02 | 491.8 | 1068.0 | 2.46 | 210.0 | 419.0 | 2.66 | 123.8 | 118.0 | 2.08 | 79.8 | 8.0 | 1.85 | 57.7 | 60.0 | 12 | 3.47 | 83.7 | 100.0 | 22 | 2.87 | 131.1 | 306.0 | 64 | 3.40 | 227.1 | 558.0 | 139 | 3.07 | 317.9 | 862.0 | 182 | 3.15 | 1103.0 | 2104.0 | 450 | 2.03 |
NR | 333 |
Username | kalle-flink |
Einbaujahr der WP | 2009-10-15 |
PLZ des Wohnortes | 37136 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Remko CMT 100 |
modulierend | |
Leistung (0/35) | 8.6 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1800 Watt DB |
elektr. Verbrauch HP gem./DB | 65 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 179 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Neubau 2009 - freistehend, 17,5er Mauerwerk + 20er Dämmung, 3fach Verglasung, Anlage ohne Solar, Holzofen für Wohnzimmer + Küche Verb. ca. 1,5m³ -> HK-Pumpe war falsch verdrahtet, daher AZ <2 im 1. Jahr, jetzt korrigiert, wird besser! |