Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2017 | 180 | 3 | 3533.0 | 11574.0* | 3.28 | 1302.0 | 3925.0 | 3.18 | 1010.0 | 3015.0 | 3.19 | 697.0 | 2148.0 | 3.38 | 524.0 | 1646.0 | 3.54 | |||||||||||||||||||||||||||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2016 | 180 | 3 | 6804.0 | 21871.0* | 3.27 | 1320.0 | 3899.0 | 3.11 | 899.0 | 2733.0 | 3.27 | 887.0 | 2655.0 | 3.23 | 531.0 | 1583.0 | 3.38 | 184.0 | 396.0 | 3.29 | 160.0 | 158.0 | 2.30 | 114.0 | 0 | 136.0 | 140.0 | 2.57 | 143.0 | 207.0 | 2.92 | 573.0 | 1871.0 | 3.63 | 847.0 | 2726.0 | 3.47 | 1010.0 | 3193.0 | 3.37 | ||||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2015 | 180 | 3 | 2581.0 | 8533.0* | 3.31 | 540.0 | 1731.0 | 3.59 | 721.0 | 2273.0 | 3.44 | 1320.0 | 3899.0 | 3.11 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2014 | 180 | 3 | 3942.0 | 11803.0* | 2.99 | 1217.0 | 3782.0 | 0 | 3.28 | 794.0 | 2424.0 | 0 | 3.32 | 696.0 | 2113.0 | 0 | 3.34 | 396.0 | 1017.0 | 0 | 3.10 | 328.0 | 710.0 | 0 | 2.80 | 224.0 | 280.0 | 0 | 2.19 | 287.0 | 7.0 | 0 | 0.76 | |||||||||||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2013 | 180 | 3 | 7452.0 | 23118.0* | 3.10 | 1286.0 | 3938.0 | 3.23 | 1149.0 | 3500.0 | 3.23 | 1163.0 | 3546.0 | 3.23 | 580.0 | 1660.0 | 3.22 | 248.0 | 457.0 | 2.69 | 192.0 | 114.0 | 1.69 | 213.0 | 5.0 | 1.01 | 188.0 | 19.0 | 1.22 | 266.0 | 625.0 | 3.14 | 447.0 | 1148.0 | 3.04 | 742.0 | 2424.0 | 3.55 | 978.0 | 3162.0 | 3.45 | |||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2012 | 180 | 3 | 6912.0 | 21415.0* | 3.18 | 1091.0 | 3426.0 | 3.33 | 1195.0 | 3641.0 | 3.22 | 677.0 | 1911.0 | 3.13 | 494.0 | 1310.0 | 3.08 | 206.0 | 372.0 | 2.83 | 121.0 | 91.0 | 2.49 | 167.0 | 12.0 | 1.33 | 183.0 | 0 | 135.0 | 208.0 | 3.10 | 518.0 | 1470.0 | 3.24 | 832.0 | 2696.0 | 3.49 | 1293.0 | 3968.0 | 3.23 | ||||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2011 | 180 | 3 | 6253.0 | 19220.0* | 3.07 | 1190.0 | 3504.0 | 3.12 | 1229.0 | 3645.0 | 3.14 | 764.0 | 2184.0 | 3.13 | 366.0 | 841.0 | 2.87 | 174.0 | 241.0 | 2.59 | 200.0 | 96.0 | 1.53 | 122.0 | 26.0 | 1.93 | 141.0 | 4.0 | 1.52 | 95.0 | 3.0 | 2.24 | 379.0 | 1065.0 | 3.36 | 748.0 | 2325.0 | 3.39 | 845.0 | 2766.0 | 3.52 | |||||||||||||||||||||||||
358 | Sole/Wasser | König - KSE12T6 | 12.8 | 2010 | 180 | 3 | 6315.0 | 18583.0* | 2.94 | 752.0 | 2005.0 | 2.95 | 784.0 | 2179.0 | 3.05 | 475.0 | 1229.0 | 3.03 | 363.0 | 881.0 | 3.01 | 229.0 | 162.0 | 1.62 | 252.0 | 1.0 | 0.84 | 71.0 | 1.0 | 2.97 | 268.0 | 576.0 | 2.93 | 557.0 | 1666.0 | 3.37 | 890.0 | 2656.0 | 3.22 | 1674.0 | 4917.0 | 3.06 |
NR | 358 |
Username | Bösewicht |
Einbaujahr der WP | 2007-07-15 |
PLZ des Wohnortes | 15345 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | König - KSE12T6 |
modulierend | |
Leistung (0/35) | 12.8 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 90.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2900 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 128 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 8.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 10.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Im Sommer läuft bei Bedarf eine passive Kühlung, welche ca. 2-7 KW tgl. verbraucht, bei Innentemperaturen >22 Grad Celsius. |