Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2018 | 200 | 2 | 6600.0 | 2259 | 1111.0 | 390 | 1496.0 | 483 | 1114.0 | 377 | 213.0 | 75 | 116.0 | 37 | 0 | 0 | 0 | 0 | 0 | 0 | 52.0 | 18 | 394.0 | 134 | 947.0 | 333 | 1157.0 | 412 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2017 | 200 | 2 | 7077.0 | 2394 | 1841.0 | 546 | 1050.0 | 375 | 642.0 | 223 | 462.0 | 165 | 154.0 | 52 | 12.0 | 5 | 0 | 0 | 14.0 | 4 | 204.0 | 67 | 394.0 | 133 | 947.0 | 336 | 1357.0 | 488 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2016 | 200 | 2 | 7025.0 | 2468 | 1255.0 | 435 | 1051.0 | 374 | 1001.0 | 356 | 464.0 | 161 | 224.0 | 78 | 55.0 | 17 | 8.0 | 3 | 4.0 | 1 | 53.0 | 17 | 564.0 | 175 | 966.0 | 354 | 1380.0 | 497 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2015 | 200 | 3 | 6516.0 | 2280 | 1338.0 | 477 | 1410.0 | 482 | 791.0 | 280 | 369.0 | 131 | 152.0 | 51 | 14.0 | 5 | 0 | 0 | 0 | 0 | 150.0 | 50 | 496.0 | 169 | 724.0 | 253 | 1072.0 | 382 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2014 | 200 | 3 | 5799.0 | 2029 | 1196.0 | 427 | 985.0 | 352 | 702.0 | 251 | 313.0 | 107 | 217.0 | 73 | 3.0 | 2 | 24.0 | 7 | 26.0 | 9 | 104.0 | 33 | 320.0 | 105 | 757.0 | 264 | 1152.0 | 399 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2013 | 200 | 3 | 8049.0 | 2813 | 1382.0 | 502 | 1429.0 | 487 | 1162.0 | 419 | 620.0 | 218 | 351.0 | 118 | 87.0 | 29 | 0 | 0 | 9.0 | 3 | 115.0 | 37 | 429.0 | 141 | 1049.0 | 369 | 1416.0 | 490 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2012 | 200 | 3 | 7173.0 | 2425 | 1276.0 | 462 | 1896.0 | 532 | 632.0 | 225 | 571.0 | 201 | 108.0 | 37 | 46.0 | 15 | 0 | 0 | 0 | 0 | 125.0 | 42 | 371.0 | 147 | 827.0 | 293 | 1321.0 | 471 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2011 | 200 | 3 | 6515.0 | 2237 | 1490.0 | 500 | 1138.0 | 390 | 803.0 | 278 | 195.0 | 47 | 64.0 | 22 | 38.0 | 13 | 19.0 | 6 | 1.0 | 1 | 63.0 | 20 | 520.0 | 181 | 1021.0 | 361 | 1163.0 | 418 | ||||||||||||||||||||||||||||||||||||||
388 | Luft/Wasser | Alpha Innotec LW 150A | 15.3 | 2010 | 200 | 3 | 2484.0 | 838 | 875.0 | 301 | 1609.0 | 537 |
NR | 388 |
Username | joerg.lorenz |
Einbaujahr der WP | 2009-06-05 |
PLZ des Wohnortes | CH-8404 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Alpha Innotec LW 150A |
modulierend | |
Leistung (0/35) | 15.3 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | teil |
WW Temperatur | 49 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 4900 Watt DB |
elektr. Verbrauch HP gem./DB | 50 Watt |
elektr. Verbrauch WQ P gem./DB | 67 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 36.5 °C |
Spreizung Heizkr. | 6.5 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | Nein |
Bemerkungen | Kombiniert mit Solarthermieanlage Soltop 10.0m2 netto/10.8 m2 brutto Flachkollektoren im Dach eingelassen zur HU+WW. 940l Schichtspeicher Strativari mit 237 l Warmwasserspeicher intern. Solarproduktion von 1.6.2013-31.5.2014 3877 KWh thermisch. Durchschn. 09-14: 3227 kWh. Haus Baujahr 1984. Doppelschalenmauerwerk. Dreifachverglaste Fenster. Boden Parkett Merbau 2007 eingebaut. Vor Sanierung 1990 l Oel pro HZ-Saison im mehrjährigen Mittel verbraucht (WW mit Elektroboiler). RLT von 32°C bezieht sich auf echte AT von 0°C. Heizgrenze automatisch bei Durchschnittstemperatur von 17° in 24h. FBH im Dez. 2012 neu abgeglichen. Die angegebene Spreizung gilt bei AT 0°C im Ein-Kompressor-Betrieb. Die WP verfügt über 2 Kompressoren. Die Stromaufnahme gilt für den Parallelbetrieb. Stromaufnahme im Solobetrieb gem. AI 3.0 kW A7/W35. Selbst gemessen 2.85 kW. Die Auslegungstemperatur am Standort beträgt -8°C. |