Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
416 | DV/DK | beglau | 7.1 | 2015 | 200 | 5 | 1923.5 | * | 1244 | 447.5 | 293 | 439.1 | 290 | 345.9 | 227 | 248.4 | 163 | 136.3 | 89 | 85.6 | 52 | 52.0 | 30 | 73.6 | 43 | 95.1 | 57 | |||||||||||||||||||||||||||||||||||||||||||
416 | DV/DK | beglau | 7.1 | 2014 | 200 | 5 | 2512.1 | * | 1683 | 459.8 | 363 | 397.7 | 262 | 275.0 | 176 | 163.0 | 97 | 133.6 | 75 | 85.8 | 44 | 85.1 | 42 | 83.9 | 42 | 93.2 | 48 | 106.6 | 64 | 244.0 | 156 | 384.4 | 314 | |||||||||||||||||||||||||||||||||||||
416 | DV/DK | beglau | 7.1 | 2013 | 200 | 5 | 2775.1 | * | 2272 | 479.8 | 389 | 452.8 | 364 | 456.7 | 365 | 242.7 | 184 | 129.8 | 88 | 72.2 | 45 | 67.3 | 37 | 76.7 | 57 | 92.7 | 75 | 122.0 | 105 | 224.3 | 212 | 358.1 | 351 | |||||||||||||||||||||||||||||||||||||
416 | DV/DK | beglau | 7.1 | 2012 | 200 | 5 | 2876.9 | * | 2557 | 540.2 | 439 | 582.7 | 445 | 334.1 | 287 | 227.5 | 238 | 124.1 | 126 | 77.3 | 72 | 53.4 | 45 | 51.7 | 45 | 74.3 | 71 | 121.3 | 129 | 260.9 | 284 | 429.4 | 376 | |||||||||||||||||||||||||||||||||||||
416 | DV/DK | beglau | 7.1 | 2011 | 200 | 5 | 3027.7 | * | 2256 | 585.3 | 520.5 | 496.0 | 232.9 | 98.1 | 57.4 | 1376 | 54.0 | 25 | 72.0 | 58 | 59.9 | 46 | 104.5 | 98 | 308.4 | 295 | 438.7 | 358 | ||||||||||||||||||||||||||||||||||||||||||
416 | DV/DK | beglau | 7.1 | 2010 | 200 | 4 | 1776.9 | * | 475.5 | 80.4 | 200.1 | 329.4 | 691.5 |
NR | 416 |
Username | eco |
Einbaujahr der WP | 2010-03-17 |
PLZ des Wohnortes | 01156 |
Bauart | DV/DK |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | beglau |
modulierend | |
Leistung (0/35) | 7.1 kW |
berechneter Primärenergiebedarf | 38.7 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.5 m |
Fläche | 433 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1200 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Flächenkollektor mit 8x100 Kupferrohr, frequenzmodulierter Verdichter außerhalb des Hauses im Schacht, Fußbodenheizung in 3 Etagen, Parkett im EG und 3 Kinder, die gerne baden oder duschen... Anschluß des ausgebauten Spitzbodens ab 10/14 mit einem weiteren, somit insgesamt 7 einzeln gesteuerte Heizkreise, d.h. insgesamt ca. 200m² Heizfläche, die gesamte Anlage wurde nochmals grundlegend gewartet: KM ausgetauscht, Steuerung angepasst, Filter gewechselt etc. |