Wärmepumpen Verbrauchsübersicht in-tostedt.de
DE PL NL UK ET
FR FR DK SV



Weiterhin alles Gute Michael Schumacher!



Anlage
NR
Bauart Hersteller
Typ
Leistung
kW
Jahr Heiz-
fläche
qm
Personen gesamt
kWh Strom
gesamt
kWh WMZ
gesamt
BStd
AZ
 
 
JAN
Strom
kWh
JAN
WMZ kWh
JAN
BStd
JAN
AZ
FEB
Strom
kWh
FEB
WMZ kWh
FEB
BStd
FEB
AZ
MAE
Strom
kWh
MAE
WMZ kWh
MAE
BStd
MAE
AZ
APR
Strom
kWh
APR
WMZ kWh
APR
BStd
APR
AZ
MAI
Strom
kWh
MAI
WMZ kWh
MAI
BStd
MAI
AZ
JUN
Strom
kWh
JUN
WMZ kWh
JUN
BStd
JUN
AZ
JUL
Strom
kWh
JUL
WMZ kWh
JUL
BStd
JUL
AZ
AUG
Strom
kWh
AUG
WMZ kWh
AUG
BStd
AUG
AZ
SEP
Strom
kWh
SEP
WMZ kWh
SEP
BStd
SEP
AZ
OKT
Strom
kWh
OKT
WMZ kWh
OKT
BStd
OKT
AZ
NOV
Strom
kWh
NOV
WMZ kWh
NOV
BStd
NOV
AZ
DEZ
Strom
kWh
DEZ
WMZ kWh
DEZ
BStd
DEZ
AZ
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8202015031919.09335.012654.86351.01740.02394.96293.01451.01984.95235.01164.01584.9568.0310.0414.5641.0168.0224.1029.0114.0153.9328.0112.0154.0028.0112.0154.0047.0200.0264.26193.0971.01295.03233.01169.01575.02373.01824.02504.89
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201915032019.09999.013514.95379.01909.02585.04259.01287.01764.97254.01266.01724.98115.0570.0774.9692.0447.0604.8628.0112.0154.0021.085.0114.0523.091.0123.9646.0220.0294.78175.0885.01185.06290.01448.01954.99337.01679.02284.98
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201815031856.09157.012414.93332.01671.02275.03337.01662.02294.93277.01384.01885.0072.0343.0464.7631.0126.0174.0622.090.0124.0919.075.0103.9522.090.0124.0944.0202.0274.59132.0662.0885.02243.01233.01655.07325.01619.02204.98
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201715032079.010298.013954.95389.01921.02654.94292.01457.01994.99199.01001.01365.03180.0906.01215.0352.0234.0314.5052.0234.0314.5026.0103.0143.9622.087.0113.9569.0341.0454.94152.0773.01025.09275.01400.01885.09371.01841.02524.96
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201615032006.09986.013464.98349.01758.02395.04320.01592.02174.98279.01405.01915.04142.0717.0965.0538.0161.0214.2428.0113.0144.0430.0118.0163.9329.0117.0154.0323.092.0124.00170.0872.01155.13274.01400.01885.11324.01641.02225.06
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201515031866.09223.012424.94379.01863.02564.92323.01602.02214.96250.01256.01705.02100.0489.0654.8949.0228.0314.6530.0123.0164.1030.0121.0164.0328.0114.0154.0759.0285.0364.83152.0775.01025.10216.01099.01465.09250.01268.01685.07
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201415031777.08663.011674.88328.01559.02114.75274.01366.01864.99180.0897.01224.9879.0380.0514.8179.0376.0504.7635.0150.0194.2929.0116.0154.0033.0143.0194.3340.0173.0224.33116.0576.0764.97229.01163.01555.08355.01764.02414.97
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201315022495.011212.015794.49480.02084.03094.34417.01815.02704.35382.01675.02474.38163.0754.01024.6388.0404.0534.5945.0183.0244.0730.0113.0143.7724.095.0133.9653.0234.0304.42140.0671.0884.79300.01434.01924.78373.01750.02374.69
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201215022666.011602.016814.35408.01774.02594.35519.02233.03324.30282.01234.01794.38241.01064.01534.4167.0284.0404.2442.0155.0213.6929.0109.0153.7633.0123.0163.7370.0299.0424.27200.0894.01254.47333.01495.02144.49442.01938.02854.38
596 Sole/WasserVaillant geoTHERM plus VWS 62/25.8201115021403.06005.08544.28140.0592.0844.2352.0202.0283.8838.0139.0193.6627.097.0133.5942.0161.0233.8354.0214.0293.96238.01057.01474.44361.01585.02264.39451.01958.02854.34
NR596
UsernameVWS62/2
Einbaujahr der WP2011-03-15
PLZ des Wohnortes58540
BauartSole/Wasser
Mono-Bi-Tri ValentMono
Hersteller TypVaillant geoTHERM plus VWS 62/2
modulierendNein
Leistung (0/35)5.8 kW
berechneter Primärenergiebedarf38.0 kWh/m²/anno
WW über WPJa
WW Temperatur40 °C
WW LegionellenschaltungNein
WW über WMZ erfasstJa (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert)
Quelle1 Erdbohrung
Tiefe112.0 m
Fläche0 m²
HeizungsartFBH
elektr. Verbrauch WP ohne NA gem./DB1300 Watt DB
elektr. Verbrauch HP gem./DB34 Watt
elektr. Verbrauch WQ P gem./DB70 Watt
Stromzähler > erfasst:
WMZ
Mittlere Raumtemp.22.0 °C
Mittlere Wärmequellentemperatur4.0 °C
Heizung max. Vorlauf Temp.30.0 °C
Spreizung Heizkr.4.0
Heizflaeche150 m²
LüftungFenster
Personen3
Grabenkollektor HelferNein
Grabenkollektor Erfahrung
Bemerkungen Achtung bei der Berechnung der JAZ bei Vaillant: Der Wärmemengenzähler zeigt nur die aus der Erde gewonnene Energie an!!!
http://www.haustechnikdialog.de/Forum/t/116629/Vaillant-VWS-82-2---Berechnung-Jahresarbeitszahl

Optimierungen:
1. Ausbau Puffer + Weiche
2. Abschaltung ERR
3. Ausbau separaten WP-Stromzähler
4. HK-Pumpe läuft nur wenn Kompressor an
5. Überhitzung auf 6K eingestellt (TEV)
6. Heizkurve 0,1
7. Einbau Hocheffizienzpumpen Febr. 2014 (Wilo Stratos Para 1-7 + Grundfos Alpha2 - Wichtig: unbedingt über Relais den Strom direkt vom Zähler holen da sonst die Platinensteuerung der WP zerstört werden könnte)


Ende Februar 2021 wurden einige Änderungen vorgenommen:
1. Ausbau rostender Bauteile aus dem Heizkreis und Tausch gegen Edelstahlbauteile (Ausdehnungsgefäß, Sicherheitsgruppe, Umwälzpumpe). Die neue Umwälzpumpe ist die gleiche wie vorher, allerdings aus Edelstahl: Grundfos Alpha2 25-60 N 180
2. Reinigung der Fußbodenheizung mit Pellets (Fa. Stahmer) und Neubefüllung
3. Einbau Heizungswasser-Reguliergerät (Magnetic HWR 15 plus). Dieses Gerät entfernt freie und gelöste Gase, reguliert den PH-Wert und filtert Magnetitschlamm
4. Austausch Sole-Pumpe gegen noch effizientere neuere Version (WILO Varios PICO-STG 25/1-7 180mm Art.Nr. 4215542 --> Verbrauch 50W)
5. Minderung der Solekonzentration auf Frostschutz -8 Grad