Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
633 | Sole/Wasser | Alpha Innotec SWC 80H | 8.9 | 2011 | 160 | 2 | 1500.0 | 5679.0 | 607 | 3.79 | 503.0 | 1952.0 | 209 | 3.88 | 387.0 | 1541.0 | 163 | 3.98 | 368.0 | 1377.0 | 152 | 3.74 | 110.0 | 376.0 | 39 | 3.42 | 69.0 | 231.0 | 24 | 3.35 | 63.0 | 202.0 | 20 | 3.21 | ||||||||||||||||||||||||||||||||||||
633 | Sole/Wasser | Alpha Innotec SWC 80H | 8.9 | 2010 | 160 | 2 | 3010.0 | 11069.0 | 1176 | 3.68 | 698.0 | 2682.0 | 292 | 3.84 | 527.0 | 2032.0 | 222 | 3.86 | 375.0 | 1310.0 | 138 | 3.49 | 164.0 | 553.0 | 57 | 3.37 | 86.0 | 288.0 | 30 | 3.35 | 88.0 | 298.0 | 29 | 3.39 | 68.0 | 210.0 | 23 | 3.09 | 69.0 | 227.0 | 23 | 3.29 | 67.0 | 225.0 | 23 | 3.36 | 78.0 | 263.0 | 26 | 3.37 | 241.0 | 860.0 | 87 | 3.57 | 549.0 | 2121.0 | 226 | 3.86 | ||||||||||||
633 | Sole/Wasser | Alpha Innotec SWC 80H | 8.9 | 2009 | 160 | 2 | 1336.0 | 4924.0 | 501 | 3.69 | 91.0 | 288.0 | 27 | 3.16 | 84.0 | 292.0 | 29 | 3.48 | 137.0 | 493.0 | 48 | 3.60 | 402.0 | 1485.0 | 146 | 3.69 | 622.0 | 2366.0 | 251 | 3.80 |
NR | 633 |
Username | olli |
Einbaujahr der WP | 2009-08-01 |
PLZ des Wohnortes | 48477 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Alpha Innotec SWC 80H |
modulierend | |
Leistung (0/35) | 8.9 kW |
berechneter Primärenergiebedarf | 65.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 130.0 m |
Fläche | 175 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1980 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 4.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 6.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |