Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2024 | 150 | 2 | 241.0 | 1160.0 | 164 | 4.81 | 241.0 | 1160.0 | 164 | 4.81 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2023 | 150 | 2 | 1336.0 | 5760.0 | 786 | 4.31 | 152.0 | 650.0 | 87 | 4.28 | 165.0 | 730.0 | 100 | 4.42 | 182.0 | 830.0 | 130 | 4.56 | 132.0 | 580.0 | 67 | 4.39 | 40.0 | 120.0 | 14 | 3.00 | 47.0 | 150.0 | 18 | 3.19 | 49.0 | 125.0 | 18 | 2.55 | 43.0 | 125.0 | 14 | 2.91 | 29.0 | 80.0 | 11 | 2.76 | 105.0 | 470.0 | 61 | 4.48 | 168.0 | 840.0 | 115 | 5.00 | 224.0 | 1060.0 | 151 | 4.73 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2022 | 150 | 2 | 1777.0 | 7740.0 | 1102 | 4.36 | 354.0 | 1630.0 | 242 | 4.60 | 324.0 | 1460.0 | 216 | 4.51 | 243.0 | 1140.0 | 167 | 4.69 | 179.0 | 820.0 | 114 | 4.58 | 73.0 | 230.0 | 31 | 3.15 | 45.0 | 140.0 | 18 | 3.11 | 44.0 | 130.0 | 16 | 2.95 | 44.0 | 130.0 | 16 | 2.95 | 34.0 | 110.0 | 14 | 3.24 | 114.0 | 480.0 | 62 | 4.21 | 124.0 | 590.0 | 82 | 4.76 | 199.0 | 880.0 | 124 | 4.42 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2021 | 150 | 2 | 2470.0 | 10790.0 | 1602 | 4.37 | 398.0 | 1780.0 | 273 | 4.47 | 366.0 | 1600.0 | 248 | 4.37 | 339.0 | 1480.0 | 225 | 4.37 | 283.0 | 1480.0 | 225 | 5.23 | 139.0 | 570.0 | 80 | 4.10 | 49.0 | 140.0 | 18 | 2.86 | 50.0 | 140.0 | 16 | 2.80 | 51.0 | 140.0 | 16 | 2.75 | 43.0 | 120.0 | 15 | 2.79 | 99.0 | 380.0 | 53 | 3.84 | 251.0 | 1130.0 | 165 | 4.50 | 402.0 | 1830.0 | 268 | 4.55 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2020 | 150 | 2 | 2285.0 | 9540.0 | 1409 | 4.18 | 351.0 | 1550.0 | 234 | 4.42 | 344.0 | 1480.0 | 225 | 4.30 | 321.0 | 1420.0 | 216 | 4.42 | 123.0 | 440.0 | 51 | 3.58 | 56.0 | 180.0 | 23 | 3.21 | 41.0 | 130.0 | 28 | 3.17 | 65.0 | 200.0 | 26 | 3.08 | 46.0 | 140.0 | 19 | 3.04 | 60.0 | 210.0 | 28 | 3.50 | 235.0 | 1000.0 | 141 | 4.26 | 282.0 | 1230.0 | 183 | 4.36 | 361.0 | 1560.0 | 235 | 4.32 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2019 | 150 | 2 | 2166.0 | 9240.0 | 1354 | 4.27 | 349.0 | 1550.0 | 238 | 4.44 | 305.0 | 1350.0 | 204 | 4.43 | 308.0 | 1300.0 | 194 | 4.22 | 181.0 | 750.0 | 105 | 4.14 | 53.0 | 180.0 | 23 | 3.40 | 45.0 | 150.0 | 20 | 3.33 | 47.0 | 150.0 | 20 | 3.19 | 49.0 | 170.0 | 21 | 3.47 | 44.0 | 140.0 | 17 | 3.18 | 201.0 | 910.0 | 131 | 4.53 | 269.0 | 1200.0 | 175 | 4.46 | 315.0 | 1390.0 | 206 | 4.41 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2018 | 150 | 2 | 2104.0 | 9000.0 | 1302 | 4.28 | 329.0 | 1500.0 | 225 | 4.56 | 347.0 | 1670.0 | 235 | 4.81 | 379.0 | 1670.0 | 252 | 4.41 | 114.0 | 440.0 | 61 | 3.86 | 61.0 | 200.0 | 29 | 3.28 | 44.0 | 150.0 | 20 | 3.41 | 43.0 | 140.0 | 19 | 3.26 | 45.0 | 140.0 | 17 | 3.11 | 55.0 | 150.0 | 18 | 2.73 | 103.0 | 370.0 | 48 | 3.59 | 275.0 | 1230.0 | 176 | 4.47 | 309.0 | 1340.0 | 202 | 4.34 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2017 | 150 | 2 | 2137.0 | 9040.0 | 1296 | 4.23 | 389.0 | 1730.0 | 262 | 4.45 | 281.0 | 1380.0 | 204 | 4.91 | 264.0 | 1040.0 | 151 | 3.94 | 205.0 | 910.0 | 128 | 4.44 | 98.0 | 355.0 | 48 | 3.62 | 63.0 | 195.0 | 26 | 3.10 | 51.0 | 150.0 | 21 | 2.94 | 55.0 | 170.0 | 21 | 3.09 | 72.0 | 210.0 | 25 | 2.92 | 119.0 | 520.0 | 66 | 4.37 | 217.0 | 930.0 | 132 | 4.29 | 323.0 | 1450.0 | 212 | 4.49 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2016 | 150 | 2 | 2067.0 | 8980.0 | 1288 | 4.34 | 338.0 | 1550.0 | 232 | 4.59 | 260.0 | 1250.0 | 180 | 4.81 | 265.0 | 1170.0 | 170 | 4.42 | 154.0 | 680.0 | 90 | 4.42 | 77.0 | 240.0 | 37 | 3.12 | 60.0 | 200.0 | 22 | 3.33 | 50.0 | 170.0 | 28 | 3.40 | 69.0 | 230.0 | 31 | 3.33 | 61.0 | 190.0 | 24 | 3.11 | 119.0 | 530.0 | 72 | 4.45 | 297.0 | 1350.0 | 192 | 4.55 | 317.0 | 1420.0 | 210 | 4.48 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2015 | 150 | 2 | 2121.0 | 9250.0 | 1333 | 4.36 | 359.0 | 1700.0 | 248 | 4.74 | 362.0 | 1600.0 | 248 | 4.42 | 240.0 | 1050.0 | 153 | 4.38 | 187.0 | 840.0 | 119 | 4.49 | 189.0 | 820.0 | 113 | 4.34 | 73.0 | 260.0 | 37 | 3.56 | 47.0 | 160.0 | 23 | 3.40 | 55.0 | 210.0 | 29 | 3.82 | 55.0 | 160.0 | 21 | 2.91 | 163.0 | 730.0 | 99 | 4.48 | 191.0 | 830.0 | 118 | 4.35 | 200.0 | 890.0 | 125 | 4.45 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2014 | 150 | 2 | 1857.0 | 7973.0 | 1136 | 4.29 | 286.0 | 1324.0 | 196 | 4.63 | 243.0 | 1091.0 | 158 | 4.49 | 234.0 | 1034.0 | 147 | 4.42 | 132.0 | 540.0 | 76 | 4.09 | 58.0 | 184.0 | 23 | 3.17 | 64.0 | 214.0 | 29 | 3.34 | 55.0 | 185.0 | 25 | 3.36 | 60.0 | 190.0 | 23 | 3.17 | 50.0 | 150.0 | 19 | 3.00 | 96.0 | 380.0 | 51 | 3.96 | 254.0 | 1169.0 | 166 | 4.60 | 325.0 | 1512.0 | 223 | 4.65 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2013 | 150 | 2-3 | 2000.0 | 8756.0 | 1245 | 4.38 | 294.0 | 1359.0 | 199 | 4.62 | 297.0 | 1391.0 | 205 | 4.68 | 310.0 | 1415.0 | 210 | 4.56 | 204.0 | 872.0 | 124 | 4.27 | 100.0 | 364.0 | 47 | 3.64 | 45.0 | 142.0 | 19 | 3.16 | 43.0 | 135.0 | 19 | 3.14 | 57.0 | 201.0 | 24 | 3.53 | 72.0 | 263.0 | 33 | 3.65 | 107.0 | 435.0 | 57 | 4.07 | 210.0 | 956.0 | 134 | 4.55 | 261.0 | 1223.0 | 174 | 4.69 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2012 | 150 | 2 | 1921.0 | 8395.0 | 1183 | 4.37 | 306.0 | 1461.0 | 210 | 4.77 | 287.0 | 1369.0 | 204 | 4.77 | 204.0 | 918.0 | 129 | 4.50 | 175.0 | 741.0 | 103 | 4.23 | 98.0 | 348.0 | 46 | 3.55 | 66.0 | 226.0 | 29 | 3.42 | 65.0 | 208.0 | 29 | 3.20 | 63.0 | 200.0 | 25 | 3.17 | 77.0 | 272.0 | 35 | 3.53 | 121.0 | 522.0 | 69 | 4.31 | 202.0 | 892.0 | 126 | 4.42 | 257.0 | 1238.0 | 178 | 4.82 | ||||||||||||
694 | Sole/Wasser | Tecalor TTF 5 cool | 5.8 | 2011 | 150 | 2 | 1890.0 | 8197.0 | 1134 | 4.34 | 320.0 | 1632.0 | 210 | 5.10 | 314.0 | 1450.0 | 214 | 4.62 | 228.0 | 1048.0 | 151 | 4.60 | 110.0 | 457.0 | 62 | 4.15 | 64.0 | 202.0 | 26 | 3.16 | 60.0 | 183.0 | 23 | 3.05 | 70.0 | 200.0 | 27 | 2.86 | 85.0 | 251.0 | 34 | 2.95 | 61.0 | 179.0 | 24 | 2.93 | 124.0 | 498.0 | 66 | 4.02 | 191.0 | 873.0 | 121 | 4.57 | 263.0 | 1224.0 | 176 | 4.65 |
NR | 694 |
Username | Schwedenhäusle |
Einbaujahr der WP | 2010-08-15 |
PLZ des Wohnortes | 25373 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Tecalor TTF 5 cool |
modulierend | |
Leistung (0/35) | 5.8 kW |
berechneter Primärenergiebedarf | 39.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 41 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 99.0 m |
Fläche | 170 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1330 Watt DB |
elektr. Verbrauch HP gem./DB | 95 Watt |
elektr. Verbrauch WQ P gem./DB | 120 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 150 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | AT-Steuerung, 21,5 Raum-SOLL, HZK 0,2. Stromverbrauch der HK-Pumpe und der Sole-Pumpe leider nicht berücksichtigt. Zusätzlich zur angegebenen Heizfläche ca. 25m² indirekt beheiztes DG, voll gedämmt. Warmwasser normal 41 Grad, Einmalladung 50 Grad vor Vollbad. Quellentemperatur ungestört 10 Grad. Spreizung VL/RL 4-5 Grad Plewa-kamin im offenen EG, häufig morgens 1-2 Stunden als Zusatzheizung für mehr RT wenn Homeoffice |