Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
718 | Luft/Wasser | Remko - CMT 160 | 12.5 | 2015 | 165 | 4 | 1647.0 | 5600.0 | 3.40 | 843.0 | 2900.0 | 3.44 | 804.0 | 2700.0 | 3.36 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
718 | Luft/Wasser | Remko - CMT 160 | 12.5 | 2014 | 165 | 4 | 3470.0 | 12200.0 | 3.52 | 593.0 | 2200.0 | 3.71 | 489.0 | 1900.0 | 3.89 | 365.0 | 1400.0 | 3.84 | 146.0 | 400.0 | 2.74 | 120.0 | 300.0 | 2.50 | 102.0 | 300.0 | 2.94 | 88.0 | 150.0 | 1.70 | 88.0 | 150.0 | 1.70 | 101.0 | 300.0 | 2.97 | 207.0 | 700.0 | 3.38 | 453.0 | 1700.0 | 3.75 | 718.0 | 2700.0 | 3.76 | |||||||||||||||||||||||||
718 | Luft/Wasser | Remko - CMT 160 | 12.5 | 2013 | 165 | 2.5 | 4629.5 | 15800.0 | 1656 | 3.41 | 850.0 | 2800.0 | 476 | 3.29 | 803.0 | 2700.0 | 496 | 3.36 | 772.0 | 2600.0 | 458 | 3.37 | 321.0 | 1200.0 | 166 | 3.74 | 174.0 | 500.0 | 60 | 2.87 | 124.0 | 400.0 | 3.23 | 115.0 | 200.0 | 1.74 | 88.0 | 200.0 | 2.27 | 115.0 | 200.0 | 1.74 | 192.7 | 800.0 | 4.15 | 500.6 | 1800.0 | 3.60 | 574.2 | 2400.0 | 4.18 | |||||||||||||||||||
718 | Luft/Wasser | Remko - CMT 160 | 12.5 | 2012 | 165 | 2.5 | 4774.7 | 14994.0 | 3.14 | 766.1 | 2687.0 | 3.51 | 1198.6 | 3107.0 | 2.59 | 362.0 | 1400.0 | 3.87 | 262.5 | 1000.0 | 3.81 | 211.0 | 300.0 | 1.42 | 107.6 | 200.0 | 1.86 | 86.1 | 200.0 | 2.32 | 139.0 | 300.0 | 2.16 | 117.3 | 300.0 | 2.56 | 307.8 | 1100.0 | 3.57 | 490.6 | 1800.0 | 3.67 | 726.1 | 2600.0 | 3.58 | |||||||||||||||||||||||||
718 | Luft/Wasser | Remko - CMT 160 | 12.5 | 2011 | 165 | 2.5 | 1379.5 | 5200.0 | 371 | 3.77 | 177.3 | 671.0 | 3.78 | 601.5 | 2099.0 | 3.49 | 600.7 | 2430.0 | 371 | 4.05 |
NR | 718 |
Username | Irzi |
Einbaujahr der WP | 2011-09-05 |
PLZ des Wohnortes | 64846 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Remko - CMT 160 |
modulierend | |
Leistung (0/35) | 12.5 kW |
berechneter Primärenergiebedarf | 110.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | sonstige |
elektr. Verbrauch WP ohne NA gem./DB | 2950 Watt DB |
elektr. Verbrauch HP gem./DB | 24 Watt |
elektr. Verbrauch WQ P gem./DB | 46 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 36.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 165 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Haus BJ1976, Stahlkonstruktionshaus + Hösch Isowände, Wandheizung. Heizleistung (0/35) bei Nennfrequenz, max 12,5kW. Leistungsaufnahme Wärmepumpe bei A7/W35. Wärmepumpe nach meinem Empfinden recht laut, jedoch keine Vergleichsmöglichkeit. |