Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
853 | Sole/Wasser | Junkers STM 60 | 6.0 | 2015 | 140 | 3 | 455.0 | 1998.0 | 262 | 4.39 | 455.0 | 1998.0 | 262 | 4.39 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
853 | Sole/Wasser | Junkers STM 60 | 6.0 | 2014 | 140 | 3 | 2549.0 | 10316.4 | 1295 | 4.05 | 390.0 | 2066.0 | 283 | 5.30 | 358.0 | 1420.0 | 201 | 3.97 | 300.0 | 1113.8 | 151 | 3.71 | 198.0 | 657.2 | 83 | 3.32 | 143.0 | 443.0 | 52 | 3.10 | 80.0 | 227.0 | 25 | 2.84 | 80.0 | 234.0 | 24 | 2.93 | 71.0 | 199.9 | 20 | 2.82 | 90.0 | 270.5 | 28 | 3.01 | 158.0 | 603.0 | 62 | 3.82 | 256.0 | 1300.0 | 145 | 5.08 | 425.0 | 1782.0 | 221 | 4.19 | ||||||||||||
853 | Sole/Wasser | Junkers STM 60 | 6.0 | 2013 | 140 | 2 | 3331.0 | 12742.9 | 1688 | 3.83 | 536.0 | 2239.0 | 316 | 4.18 | 515.0 | 2131.0 | 306 | 4.14 | 511.0 | 2060.0 | 299 | 4.03 | 296.0 | 1096.0 | 153 | 3.70 | 151.0 | 442.0 | 56 | 2.93 | 93.0 | 263.0 | 29 | 2.83 | 67.0 | 236.0 | 25 | 3.52 | 67.0 | 220.0 | 21 | 3.28 | 123.0 | 431.8 | 45 | 3.51 | 182.0 | 639.3 | 69 | 3.51 | 319.0 | 1417.0 | 167 | 4.44 | 471.0 | 1567.8 | 202 | 3.33 | ||||||||||||
853 | Sole/Wasser | Junkers STM 60 | 6.0 | 2012 | 140 | 2 | 3519.0 | 7784.6 | 943 | 3.95 | 484.0 | 649.0 | 417.0 | 350.0 | 1411.5 | 171 | 4.03 | 162.0 | 553.1 | 69 | 3.41 | 129.0 | 434.0 | 49 | 3.36 | 80.0 | 240.0 | 34 | 3.00 | 76.0 | 235.0 | 14 | 3.09 | 129.0 | 447.0 | 48 | 3.47 | 255.0 | 1090.0 | 119 | 4.27 | 367.0 | 1621.0 | 198 | 4.42 | 421.0 | 1753.0 | 241 | 4.16 | |||||||||||||||||||||
853 | Sole/Wasser | Junkers STM 60 | 6.0 | 2011 | 140 | 2 | 1323.0 | 782.0 | 541.0 |
NR | 853 |
Username | doc |
Einbaujahr der WP | 2011-10-01 |
PLZ des Wohnortes | 23617 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Junkers STM 60 |
modulierend | Nein |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 52.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Kollektormatten |
Tiefe | 1.6 m |
Fläche | 90 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | kein Kaminofen |