Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2018 | 225 | 4 | 771.0 | 2919.0 | 268 | 3.79 | 137.0 | 547.0 | 45 | 3.99 | 330.0 | 1180.0 | 118 | 3.58 | 178.0 | 702.0 | 64 | 3.94 | 126.0 | 490.0 | 41 | 3.89 | ||||||||||||||||||||||||||||||||||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2017 | 225 | 4 | 1526.0 | 5703.0 | 503 | 3.74 | 291.0 | 991.0 | 101 | 3.41 | 163.0 | 665.0 | 60 | 4.08 | 116.0 | 459.0 | 40 | 3.96 | 118.0 | 456.0 | 39 | 3.86 | 63.0 | 185.0 | 14 | 2.94 | 55.0 | 208.0 | 15 | 3.78 | 57.0 | 215.0 | 15 | 3.77 | 53.0 | 158.0 | 11 | 2.98 | 54.0 | 216.0 | 18 | 4.00 | 72.0 | 239.0 | 18 | 3.32 | 234.0 | 952.0 | 84 | 4.07 | 250.0 | 959.0 | 88 | 3.84 | ||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2016 | 225 | 4 | 2004.0 | 7388.0 | 671 | 3.69 | 595.0 | 2156.0 | 210 | 3.62 | 467.0 | 1842.0 | 174 | 3.94 | 140.0 | 490.0 | 43 | 3.50 | 47.0 | 155.0 | 13 | 3.30 | 36.0 | 103.0 | 7 | 2.86 | 66.0 | 226.0 | 17 | 3.42 | 64.0 | 224.0 | 16 | 3.50 | 58.0 | 196.0 | 15 | 3.38 | 59.0 | 199.0 | 14 | 3.37 | 101.0 | 411.0 | 34 | 4.07 | 158.0 | 622.0 | 55 | 3.94 | 213.0 | 764.0 | 73 | 3.59 | ||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2015 | 225 | 4 | 1386.0 | 5217.0 | 438 | 3.76 | 221.0 | 785.0 | 72 | 3.55 | 203.0 | 725.0 | 67 | 3.57 | 86.0 | 303.0 | 25 | 3.52 | 100.0 | 375.0 | 32 | 3.75 | 88.0 | 375.0 | 25 | 4.26 | 64.0 | 218.0 | 16 | 3.41 | 60.0 | 205.0 | 13 | 3.42 | 49.0 | 160.0 | 12 | 3.27 | 38.0 | 110.0 | 8 | 2.89 | 133.0 | 558.0 | 47 | 4.20 | 166.0 | 654.0 | 57 | 3.94 | 178.0 | 749.0 | 64 | 4.21 | ||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2014 | 225 | 4 | 2403.0 | 9703.0 | 849 | 4.04 | 433.0 | 1731.0 | 159 | 4.00 | 378.0 | 1536.0 | 141 | 4.06 | 275.0 | 1137.0 | 103 | 4.13 | 125.0 | 500.0 | 42 | 4.00 | 124.0 | 496.0 | 40 | 4.00 | 63.0 | 223.0 | 16 | 3.54 | 56.0 | 197.0 | 14 | 3.52 | 56.0 | 201.0 | 15 | 3.59 | 59.0 | 211.0 | 16 | 3.58 | 129.0 | 552.0 | 45 | 4.28 | 309.0 | 1372.0 | 118 | 4.44 | 396.0 | 1547.0 | 140 | 3.91 | ||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2013 | 225 | 4 | 3277.0 | 12349.0 | 1153 | 3.77 | 614.0 | 2188.0 | 217 | 3.56 | 585.0 | 2097.0 | 212 | 3.58 | 478.0 | 1808.0 | 178 | 3.78 | 229.0 | 931.0 | 81 | 4.07 | 143.0 | 588.0 | 50 | 4.11 | 66.0 | 232.0 | 17 | 3.52 | 63.0 | 220.0 | 15 | 3.49 | 63.0 | 215.0 | 16 | 3.41 | 75.0 | 267.0 | 21 | 3.56 | 141.0 | 581.0 | 48 | 4.12 | 364.0 | 1455.0 | 134 | 4.00 | 456.0 | 1767.0 | 164 | 3.88 | ||||||||||||
909 | Luft/Wasser | Vaillant -- VWL 101/3 S | 9.6 | 2012 | 225 | 4 | 1590.0 | 5987.0 | 3.77 | 145.0 | 474.0 | 3.27 | 111.0 | 345.0 | 3.11 | 92.0 | 291.0 | 3.16 | 90.0 | 282.0 | 3.13 | 73.0 | 243.0 | 3.33 | 215.0 | 905.0 | 4.21 | 337.0 | 1493.0 | 4.43 | 527.0 | 1954.0 | 3.71 |
NR | 909 |
Username | just-smart |
Einbaujahr der WP | 2011-12-01 |
PLZ des Wohnortes | 66780 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant -- VWL 101/3 S |
modulierend | |
Leistung (0/35) | 9.6 kW |
berechneter Primärenergiebedarf | 58.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 225 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | seit 24.12.2014 zusätzlich Wärmequelle durch Pelletofen Olsberg Levana Aqua mit Pufferspeicheranbindung |