Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2019 | 180 | 2 | 3113.0 | 13382.0 | 4.30 | 1089.0 | 4202.0 | 0 | 3.86 | 690.0 | 2970.0 | 0 | 4.30 | 655.0 | 2856.0 | 0 | 4.36 | 337.0 | 1610.0 | 0 | 4.78 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 342.0 | 1744.0 | 0 | 5.10 | |||||||||||||||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2018 | 180 | 2 | 5417.0 | 22630.0 | 4.18 | 824.0 | 3536.0 | 0 | 4.29 | 1247.0 | 4356.0 | 0 | 3.49 | 952.0 | 3901.0 | 0 | 4.10 | 302.0 | 1525.0 | 0 | 5.05 | 133.0 | 666.0 | 0 | 5.01 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 151.0 | 724.0 | 0 | 4.79 | 357.0 | 1648.0 | 0 | 4.62 | 642.0 | 2883.0 | 0 | 4.49 | 809.0 | 3391.0 | 0 | 4.19 | ||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2017 | 180 | 2 | 5907.0 | 24297.0 | 4.11 | 1330.0 | 4508.0 | 0 | 3.39 | 818.0 | 3288.0 | 0 | 4.02 | 616.0 | 2749.0 | 0 | 4.46 | 626.0 | 2700.0 | 0 | 4.31 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 38.0 | 205.0 | 0 | 5.39 | 244.0 | 1242.0 | 0 | 5.09 | 378.0 | 1878.0 | 0 | 4.97 | 751.0 | 3215.0 | 0 | 4.28 | 1106.0 | 4512.0 | 0 | 4.08 | ||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2016 | 180 | 2 | 5854.0 | 24076.0 | 4.11 | 955.0 | 3781.0 | 0 | 3.96 | 898.0 | 3614.0 | 0 | 4.02 | 903.0 | 3653.0 | 0 | 4.05 | 541.0 | 2345.0 | 0 | 4.33 | 230.0 | 1163.0 | 0 | 5.06 | 0 | 0 | 0 | 69.0 | 348.0 | 0 | 5.04 | 595.0 | 2634.0 | 0 | 4.43 | 722.0 | 2859.0 | 0 | 3.96 | 941.0 | 3679.0 | 0 | 3.91 | ||||||||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2015 | 180 | 2 | 5432.0 | 24313.0 | 4.48 | 921.0 | 3910.0 | 0 | 4.25 | 949.0 | 3908.0 | 0 | 4.12 | 768.0 | 3413.0 | 0 | 4.44 | 524.0 | 2352.0 | 0 | 4.49 | 269.0 | 1346.0 | 0 | 5.00 | 71.0 | 384.0 | 0 | 5.41 | 15.0 | 83.0 | 0 | 5.53 | 47.0 | 249.0 | 0 | 5.30 | 245.0 | 1236.0 | 0 | 5.04 | 488.0 | 2278.0 | 0 | 4.67 | 542.0 | 2437.0 | 0 | 4.50 | 593.0 | 2717.0 | 0 | 4.58 | |||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2014 | 180 | 2 | 5210.0 | 22143.0 | 4.25 | 1168.0 | 3847.0 | 3.29 | 856.0 | 3330.0 | 0 | 3.89 | 689.0 | 2973.0 | 0 | 4.31 | 347.0 | 1767.0 | 0 | 5.09 | 301.0 | 1576.0 | 0 | 5.24 | 0 | 0 | 0 | 0 | 0 | 0 | 29.0 | 204.0 | 0 | 7.03 | 145.0 | 785.0 | 0 | 5.41 | 280.0 | 1478.0 | 0 | 5.28 | 504.0 | 2404.0 | 0 | 4.77 | 891.0 | 3779.0 | 0 | 4.24 | ||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2013 | 180 | 2 | 7227.0 | 26619.0 | 1920 | 3.68 | 1700.0 | 5105.0 | 619 | 3.00 | 1600.0 | 4871.0 | 682 | 3.04 | 649.0 | 2688.0 | 619 | 4.14 | 367.0 | 1930.0 | 0 | 5.26 | 120.0 | 583.0 | 0 | 4.86 | 13.0 | 135.0 | 0 | 10.38 | 41.0 | 255.0 | 0 | 6.22 | 225.0 | 1286.0 | 0 | 5.72 | 393.0 | 2111.0 | 0 | 5.37 | 978.0 | 3851.0 | 0 | 3.94 | 1141.0 | 3804.0 | 0 | 3.33 | ||||||||||||||||
927 | Luft/Wasser | Remko CMT 180 | 9.0 | 2012 | 180 | 2 | 2587.0 | 3063.0 | 1137 | 1.18 | 756.0 | 1230.0 | 513 | 1.63 | 1831.0 | 1833.0 | 624 | 1.00 |
NR | 927 |
Username | Molly |
Einbaujahr der WP | 2013-01-29 |
PLZ des Wohnortes | 40822 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Remko CMT 180 |
modulierend | |
Leistung (0/35) | 9.0 kW |
berechneter Primärenergiebedarf | 135.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 10 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 3050 Watt DB |
elektr. Verbrauch HP gem./DB | 25 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 8.1 °C |
Heizung max. Vorlauf Temp. | 42.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 180 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Altbau Bj.57 Hohlblock Beton Mauerwerk 22cm - Styropor 12 mm - Hochlochziegel verklinkert 5cm, Dach gedämmt mit U=0,32. Einbau Schwerkraft Ventile ( geringer Widerstand) und erneut hydr. Abgleich über Rücklauf Ventile. HKP Grundfos Alpha2 25-60 Stufe CP2. Abgleich der Volumenströme im Pufferspeicher. ~1500 l/h Stromverbrauch inkl. HK-Pumpe/WP-Pumpe . Ab AUG 2016 180 qm. |