Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2023 | 150 | 2 | 2559.0 | 5578.0* | 868 | 2.18 | 1023.0 | 2060.0 | 291 | 2.15 | 884.0 | 1773.0 | 254 | 2.16 | 652.0 | 1325.0 | 323 | 2.25 | ||||||||||||||||||||||||||||||||||||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2022 | 150 | 2 | 6340.0 | 12319.0* | 1651 | 2.00 | 1069.0 | 2260.0 | 310 | 2.25 | 851.0 | 1791.0 | 253 | 2.27 | 820.0 | 1628.0 | 225 | 2.16 | 581.0 | 1111.0 | 156 | 2.15 | 462.0 | 208.0 | 40 | 0.75 | 36.0 | 0 | 17 | 25.0 | 0 | 12 | 116.0 | 0 | 14 | 262.0 | 239.0 | 40 | 1.45 | 276.0 | 370.0 | 60 | 1.85 | 684.0 | 1295.0 | 186 | 2.10 | 1158.0 | 2157.0 | 338 | 1.98 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2021 | 150 | 2 | 7213.0 | 15214.0* | 2033 | 2.19 | 1084.0 | 2284.0 | 384 | 2.24 | 1200.0 | 2460.0 | 376 | 2.17 | 842.0 | 1844.0 | 242 | 2.36 | 733.0 | 1578.0 | 206 | 2.34 | 333.0 | 759.0 | 97 | 2.70 | 157.0 | 0 | 16 | 124.0 | 0 | 15 | 148.0 | 45.0 | 18 | 1.25 | 252.0 | 207.0 | 37 | 1.38 | 416.0 | 756.0 | 102 | 2.15 | 794.0 | 1650.0 | 218 | 2.25 | 1130.0 | 2231.0 | 322 | 2.10 | ||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2020 | 150 | 2 | 6576.0 | 13982.0* | 1571 | 2.34 | 1062.0 | 2406.0 | 291 | 2.40 | 901.0 | 2065.0 | 244 | 2.45 | 803.0 | 1789.0 | 224 | 2.40 | 443.0 | 866.0 | 114 | 2.27 | 330.0 | 555.0 | 75 | 2.11 | 155.0 | 0 | 18 | 305.0 | 0 | 6 | 153.0 | 0 | 8 | 268.0 | 115.0 | 34 | 0.95 | 379.0 | 945.0 | 88 | 2.86 | 760.0 | 1768.0 | 202 | 2.51 | 1017.0 | 2213.0 | 267 | 2.31 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2019 | 150 | 2 | 7091.0 | 14680.0* | 1725 | 2.20 | 1222.0 | 2860.0 | 378 | 2.45 | 898.0 | 2116.0 | 260 | 2.51 | 652.0 | 1563.0 | 193 | 2.61 | 700.0 | 1064.0 | 136 | 1.72 | 500.0 | 669.0 | 89 | 1.62 | 150.0 | 0 | 14 | 160.0 | 0 | 14 | 118.0 | 0 | 16 | 181.0 | 254.0 | 10 | 2.18 | 291.0 | 458.0 | 69 | 2.05 | 993.0 | 1953.0 | 238 | 2.11 | 1226.0 | 2483.0 | 308 | 2.14 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2018 | 150 | 2 | 7470.0 | 15836.0* | 1971 | 2.24 | 1264.0 | 2464.0 | 320 | 2.06 | 1201.0 | 2547.0 | 372 | 2.24 | 1210.0 | 2641.0 | 363 | 2.30 | 416.0 | 874.0 | 107 | 2.44 | 341.0 | 385.0 | 57 | 1.54 | 155.0 | 0 | 20 | 126.0 | 0 | 15 | 127.0 | 0 | 13 | 291.0 | 349.0 | 49 | 1.68 | 476.0 | 1003.0 | 122 | 2.40 | 922.0 | 2117.0 | 265 | 2.45 | 941.0 | 2196.0 | 268 | 2.48 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2017 | 150 | 2 | 7129.0 | 16184.0* | 1945 | 2.39 | 1380.0 | 3526.0 | 443 | 2.66 | 1054.0 | 2452.0 | 319 | 2.46 | 802.0 | 1843.0 | 224 | 2.47 | 677.0 | 1495.0 | 186 | 2.42 | 367.0 | 547.0 | 74 | 1.87 | 119.0 | 0 | 16 | 120.0 | 0 | 17 | 124.0 | 0 | 18 | 380.0 | 460.0 | 64 | 1.58 | 330.0 | 660.0 | 81 | 2.42 | 795.0 | 1746.0 | 220 | 2.37 | 981.0 | 2195.0 | 283 | 2.38 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2016 | 150 | 2 | 7315.0 | 15441.0* | 1943 | 2.23 | 1384.0 | 2907.0 | 386 | 2.20 | 1121.0 | 2596.0 | 267 | 2.44 | 754.0 | 1742.0 | 286 | 2.50 | 595.0 | 1227.0 | 156 | 2.30 | 268.0 | 326.0 | 50 | 1.74 | 127.0 | 0 | 19 | 121.0 | 0 | 16 | 141.0 | 0 | 20 | 165.0 | 98.0 | 27 | 1.44 | 539.0 | 1124.0 | 133 | 2.35 | 966.0 | 2182.0 | 281 | 2.40 | 1134.0 | 1979.0 | 302 | 1.87 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2015 | 150 | 2 | 6706.0 | 15035.0* | 1786 | 2.38 | 1116.0 | 2666.0 | 338 | 2.51 | 1140.0 | 2660.0 | 349 | 2.46 | 947.0 | 2249.0 | 275 | 2.52 | 522.0 | 1109.0 | 143 | 2.39 | 423.0 | 505.0 | 68 | 1.52 | 134.0 | 0 | 22 | 129.0 | 0 | 13 | 125.0 | 0 | 19 | 289.0 | 311.0 | 45 | 1.56 | 503.0 | 1065.0 | 132 | 2.40 | 661.0 | 1502.0 | 184 | 2.48 | 717.0 | 1708.0 | 198 | 2.58 | |||||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2014 | 150 | 2 | 6796.0 | 14675.0* | 1740 | 2.16 | 1278.0 | 3012.0 | 406 | 2.47 | 858.0 | 2117.0 | 260 | 2.63 | 737.0 | 1689.0 | 209 | 2.48 | 431.0 | 854.0 | 107 | 2.31 | 351.0 | 375.0 | 59 | 1.47 | 132.0 | 5.0 | 17 | 1.10 | 130.0 | 3.0 | 16 | 1.10 | 130.0 | 4.0 | 17 | 1.11 | 143.0 | 17.0 | 19 | 1.10 | 463.0 | 572.0 | 78 | 1.54 | 801.0 | 1470.0 | 184 | 2.01 | 1342.0 | 2877.0 | 368 | 2.25 | ||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2013 | 150 | 2 | 7384.0 | 17778.1* | 2197 | 2.41 | 1055.0 | 3052.0 | 437 | 3.03 | 1091.0 | 2509.0 | 347 | 2.43 | 1306.0 | 2976.0 | 421 | 2.39 | 597.0 | 1412.0 | 178 | 2.60 | 388.0 | 500.0 | 65 | 1.65 | 204.0 | 142.0 | 29 | 1.38 | 112.0 | 9.0 | 15 | 1.33 | 110.0 | 0.1 | 12 | 1.27 | 269.0 | 273.0 | 43 | 1.54 | 384.0 | 789.0 | 98 | 2.42 | 831.0 | 1918.0 | 243 | 2.48 | 1037.0 | 2518.0 | 309 | 2.56 | ||||||||||||
945 | Luft/Wasser | Niebe-Figher 2025-10 | 10.0 | 2012 | 150 | 2 | 4499.0 | 7257.0* | 1240 | 1.91 | 697.0 | 170 | 321.0 | 250.0 | 56 | 1.21 | 234.0 | 38.0 | 236 | 0.76 | 111.0 | 14.0 | 4 | 1.39 | 104.0 | 1.0 | 13 | 1.36 | 258.0 | 219.0 | 39 | 1.39 | 574.0 | 982.0 | 121 | 1.95 | 908.0 | 1836.0 | 235 | 2.18 | 1292.0 | 2797.0 | 366 | 2.27 |
NR | 945 |
Username | Energie.la-alt |
Einbaujahr der WP | 2012-04-01 |
PLZ des Wohnortes | 31275 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Niebe-Figher 2025-10 |
modulierend | |
Leistung (0/35) | 10.0 kW |
berechneter Primärenergiebedarf | 80.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 40 Watt |
elektr. Verbrauch WQ P gem./DB | 40 Watt |
Stromzähler | extern_geeicht > erfasst: |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 5.0 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 10.0 |
Heizflaeche | 150 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | 1.HK Radiatoren 50m², 2.HK Fußbodenheizung 100m², Ab Mai 2012 mit Wärmezähler für die Heizung. Sept./Okt. 2019: 3 Wochen Wochen WP aus, da Elektronik defekt. |