Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2014 | 255 | 4 | 2200.0 | 10432.0 | 804 | 4.74 | 668.0 | 3118.0 | 244 | 4.67 | 563.0 | 2646.0 | 207 | 4.70 | 501.0 | 2378.0 | 183 | 4.75 | 251.0 | 1238.0 | 93 | 4.93 | 217.0 | 1052.0 | 77 | 4.85 | ||||||||||||||||||||||||||||||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2013 | 255 | 4 | 5372.4 | 24898.0 | 1944 | 4.63 | 923.0 | 4158.0 | 336 | 4.50 | 916.0 | 4158.0 | 332 | 4.54 | 756.0 | 3415.0 | 277 | 4.52 | 430.0 | 2012.0 | 157 | 4.68 | 293.4 | 1397.0 | 105 | 4.76 | 150.0 | 696.0 | 52 | 4.64 | 68.0 | 296.0 | 21 | 4.35 | 106.0 | 464.0 | 34 | 4.38 | 264.0 | 1289.0 | 64 | 4.88 | 301.0 | 1478.0 | 80 | 4.91 | 606.0 | 2883.0 | 281 | 4.76 | 559.0 | 2652.0 | 205 | 4.74 | ||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2012 | 255 | 4 | 5032.7 | 23528.0 | 1854 | 4.68 | 827.4 | 3811.0 | 308 | 4.61 | 1028.0 | 4575.0 | 382 | 4.45 | 458.7 | 2154.0 | 170 | 4.70 | 321.4 | 1518.0 | 117 | 4.72 | 321.4 | 1518.0 | 118 | 4.72 | 155.4 | 712.0 | 53 | 4.58 | 76.0 | 349.0 | 25 | 4.59 | 76.8 | 349.0 | 25 | 4.54 | 170.0 | 840.0 | 61 | 4.94 | 403.3 | 1981.0 | 150 | 4.91 | 609.0 | 2927.0 | 226 | 4.81 | 585.3 | 2794.0 | 219 | 4.77 | ||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2011 | 255 | 4 | 5155.8 | 23908.0 | 1826 | 4.64 | 885.0 | 3963.0 | 264 | 4.48 | 791.0 | 3530.0 | 290 | 4.46 | 685.6 | 3110.0 | 252 | 4.54 | 404.5 | 1907.0 | 148 | 4.71 | 272.0 | 1259.0 | 96 | 4.63 | 113.0 | 526.0 | 39 | 4.65 | 89.0 | 426.0 | 30 | 4.79 | 125.0 | 663.0 | 42 | 5.30 | 189.0 | 832.0 | 67 | 4.40 | 399.0 | 1955.0 | 148 | 4.90 | 483.0 | 2361.0 | 182 | 4.89 | 719.7 | 3376.0 | 268 | 4.69 | ||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2010 | 255 | 4 | 5698.5 | 26479.0 | 2285 | 4.65 | 995.0 | 4448.0 | 469 | 4.47 | 654.5 | 3020.0 | 247 | 4.61 | 684.6 | 3154.0 | 256 | 4.61 | 431.7 | 2060.0 | 161 | 4.77 | 351.4 | 1682.0 | 128 | 4.79 | 141.0 | 642.0 | 48 | 4.55 | 67.0 | 261.0 | 19 | 3.90 | 77.6 | 330.0 | 25 | 4.25 | 251.0 | 1263.0 | 93 | 5.03 | 472.5 | 2292.0 | 182 | 4.85 | 628.8 | 2984.0 | 235 | 4.75 | 943.4 | 4343.0 | 422 | 4.60 | ||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2009 | 255 | 3 | 4970.7 | 22711.0 | 1797 | 4.57 | 958.2 | 4268.0 | 353 | 4.45 | 756.2 | 3381.0 | 277 | 4.47 | 653.6 | 2972.0 | 237 | 4.55 | 294.0 | 1315.0 | 100 | 4.47 | 224.0 | 1003.0 | 74 | 4.48 | 190.3 | 847.0 | 64 | 4.45 | 51.0 | 203.0 | 15 | 3.98 | 55.1 | 209.0 | 15 | 3.79 | 113.8 | 533.0 | 38 | 4.68 | 454.0 | 2215.0 | 169 | 4.88 | 479.4 | 2315.0 | 178 | 4.83 | 741.1 | 3450.0 | 277 | 4.66 | ||||||||||||
95 | Sole/Wasser | Viessmann Vitocal 300 BWC 110 | 10.8 | 2008 | 255 | 3 | 5498.7 | 25173.0 | 1993 | 4.58 | 873.6 | 3990.0 | 322 | 4.57 | 774.2 | 3535.0 | 287 | 4.57 | 766.0 | 3487.0 | 286 | 4.55 | 598.2 | 2742.0 | 219 | 4.58 | 220.4 | 990.0 | 76 | 4.49 | 87.6 | 361.0 | 26 | 4.12 | 97.9 | 431.0 | 32 | 4.40 | 85.0 | 356.0 | 26 | 4.19 | 239.9 | 1134.0 | 85 | 4.73 | 406.7 | 1917.0 | 145 | 4.71 | 598.4 | 2804.0 | 217 | 4.69 | 750.8 | 3426.0 | 272 | 4.56 |
NR | 95 |
Username | veit888 |
Einbaujahr der WP | 2007-10-10 |
PLZ des Wohnortes | 08289 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 300 BWC 110 |
modulierend | |
Leistung (0/35) | 10.8 kW |
berechneter Primärenergiebedarf | 57.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 47 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 85.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2400 Watt DB |
elektr. Verbrauch HP gem./DB | 63 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 7.8 |
Heizflaeche | 255 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |