Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
97 | Sole/Wasser | Nibe Fighter 1240 | 6.0 | 2011 | 130 | 3 | 1715.0 | 4607.0* | 811 | 2.69 | 500.0 | 1246.0 | 255 | 2.91 | 517.0 | 1202.0 | 253 | 2.73 | 451.0 | 948.0 | 210 | 2.57 | 247.0 | 371.0 | 93 | 2.35 | ||||||||||||||||||||||||||||||||||||||||||||
97 | Sole/Wasser | Nibe Fighter 1240 | 6.0 | 2010 | 130 | 3 | 3822.0 | 10679.0* | 1671 | 2.79 | 705.0 | 1737.0 | 353 | 2.76 | 521.0 | 1120.0 | 255 | 2.55 | 445.0 | 958.0 | 218 | 2.62 | 302.0 | 597.0 | 122 | 2.67 | 231.0 | 428.0 | 80 | 2.76 | 124.0 | 133.0 | 30 | 2.77 | 52.0 | 18.0 | 14 | 4.38 | 78.0 | 12.0 | 20 | 2.85 | 150.0 | 192.0 | 37 | 2.68 | 246.0 | 460.0 | 82 | 2.72 | 341.0 | 955.0 | 131 | 3.42 | 627.0 | 1549.0 | 329 | 2.81 | ||||||||||||
97 | Sole/Wasser | Nibe Fighter 1240 | 6.0 | 2009 | 130 | 3 | 3418.0 | 7895.0* | 523 | 2.88 | 587.0 | 1455.0 | 2.84 | 504.0 | 1248.0 | 2.89 | 438.0 | 240.0 | 183.0 | 250.0 | 2.51 | 140.0 | 132.0 | 38 | 2.44 | 82.0 | 20.0 | 21 | 2.80 | 66.0 | 18.0 | 17 | 3.45 | 116.0 | 87.0 | 26 | 2.56 | 244.0 | 562.0 | 79 | 3.16 | 304.0 | 736.0 | 112 | 3.11 | 514.0 | 1287.0 | 230 | 2.91 |
NR | 97 |
Username | Empryse |
Einbaujahr der WP | 2008-11-15 |
PLZ des Wohnortes | 17489 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Nibe Fighter 1240 |
modulierend | |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 125.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Kollektormatten |
Tiefe | 1.5 m |
Fläche | 104 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 55.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 130 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | keinen Pufferspeicher |