Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
971 | Sole/Wasser | Vaillant - VWS 63/3 | 6.1 | 2016 | 128 | 2 | 1024.0 | 4921.0 | 706 | 4.81 | 319.0 | 1533.0 | 222 | 4.81 | 296.0 | 1420.0 | 207 | 4.80 | 261.0 | 1242.0 | 181 | 4.76 | 148.0 | 726.0 | 96 | 4.91 | ||||||||||||||||||||||||||||||||||||||||||||
971 | Sole/Wasser | Vaillant - VWS 63/3 | 6.1 | 2015 | 128 | 2 | 989.0 | 4893.0 | 678 | 4.95 | 290.0 | 1425.0 | 203 | 4.91 | 316.0 | 1480.0 | 222 | 4.68 | 166.0 | 878.0 | 107 | 5.29 | 217.0 | 1110.0 | 146 | 5.12 | ||||||||||||||||||||||||||||||||||||||||||||
971 | Sole/Wasser | Vaillant - VWS 63/3 | 6.1 | 2014 | 128 | 2 | 1452.0 | 7152.0 | 1005 | 4.93 | 322.0 | 1580.0 | 232 | 4.91 | 262.0 | 1249.0 | 187 | 4.77 | 184.0 | 884.0 | 127 | 4.80 | 104.0 | 500.0 | 67 | 4.81 | 59.0 | 282.0 | 43 | 4.78 | 67.0 | 359.0 | 40 | 5.36 | 164.0 | 874.0 | 106 | 5.33 | 290.0 | 1424.0 | 203 | 4.91 | ||||||||||||||||||||||||||||
971 | Sole/Wasser | Vaillant - VWS 63/3 | 6.1 | 2013 | 128 | 2 | 1828.2 | 8804.0 | 1202 | 4.82 | 418.0 | 1992.0 | 297 | 4.77 | 347.0 | 1649.0 | 249 | 4.75 | 360.0 | 1687.0 | 256 | 4.69 | 186.7 | 882.0 | 131 | 4.72 | 79.5 | 380.0 | 48 | 4.78 | 124.0 | 661.0 | 5.33 | 313.0 | 1553.0 | 221 | 4.96 | |||||||||||||||||||||||||||||||||
971 | Sole/Wasser | Vaillant - VWS 63/3 | 6.1 | 2012 | 128 | 2 | 641.0 | 3259.0 | 580 | 5.08 | 256.0 | 1376.0 | 300 | 5.38 | 385.0 | 1883.0 | 280 | 4.89 |
NR | 971 |
Username | michael-j |
Einbaujahr der WP | 2012-10-20 |
PLZ des Wohnortes | 22549 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant - VWS 63/3 |
modulierend | |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 41.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.8 m |
Fläche | 120 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 28.0 °C |
Spreizung Heizkr. | 4.0 |
Heizflaeche | 128 m² |
Lüftung | zenKWL |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |