Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2023 | 145 | 7226.0 | 955.0 | 791.0 | 866.0 | 531.0 | 540.0 | 290.0 | 327.0 | 315.0 | 406.0 | 566.0 | 806.0 | 833.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2022 | 145 | 3 | 8260.0 | 1059.0 | 858.0 | 981.0 | 839.0 | 599.0 | 336.0 | 287.0 | 287.0 | 437.0 | 557.0 | 833.0 | 1187.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2021 | 145 | 3 | 8847.0 | 8213.0 | 2.51 | 1082.0 | 2893.0 | 2.67 | 1208.0 | 2785.0 | 2.31 | 984.0 | 2535.0 | 2.58 | 820.0 | 642.0 | 264.0 | 359.0 | 436.0 | 460.0 | 804.0 | 924.0 | 864.0 | |||||||||||||||||||||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2020 | 145 | 3 | 7121.0 | 19944.0 | 2.80 | 1022.0 | 2235.0 | 2.19 | 695.0 | 1913.0 | 2.75 | 741.0 | 2146.0 | 2.90 | 612.0 | 1838.0 | 3.00 | 539.0 | 1568.0 | 2.91 | 301.0 | 977.0 | 3.25 | 242.0 | 744.0 | 3.07 | 163.0 | 1032.0 | 6.33 | 438.0 | 1328.0 | 3.03 | 611.0 | 1788.0 | 2.93 | 800.0 | 1992.0 | 2.49 | 957.0 | 2383.0 | 2.49 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2019 | 145 | 3 | 7322.0 | 18596.0 | 2.54 | 1336.0 | 2412.0 | 1.81 | 676.0 | 2011.0 | 2.97 | 722.0 | 1851.0 | 2.56 | 644.0 | 1549.0 | 2.41 | 534.0 | 1553.0 | 2.91 | 175.0 | 678.0 | 3.87 | 260.0 | 742.0 | 2.85 | 215.0 | 588.0 | 2.73 | 471.0 | 1522.0 | 3.23 | 475.0 | 1686.0 | 3.55 | 951.0 | 1857.0 | 1.95 | 863.0 | 2147.0 | 2.49 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2018 | 145 | 3 | 6610.0 | 15997.0 | 2.42 | 752.0 | 2074.0 | 2.76 | 1316.0 | 2494.0 | 1.90 | 1005.0 | 2342.0 | 2.33 | 567.0 | 1575.0 | 2.78 | 336.0 | 1195.0 | 3.56 | 100.0 | 206.0 | 2.06 | 100.0 | 214.0 | 2.14 | 103.0 | 210.0 | 2.04 | 247.0 | 597.0 | 2.42 | 514.0 | 1286.0 | 2.50 | 739.0 | 1806.0 | 2.44 | 831.0 | 1998.0 | 2.40 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2017 | 145 | 3 | 6969.0 | 17194.0 | 2.47 | 1371.0 | 2732.0 | 1.99 | 781.0 | 1431.0 | 1.83 | 555.0 | 1865.0 | 3.36 | 700.0 | 1851.0 | 2.64 | 436.0 | 1342.0 | 3.08 | 96.0 | 248.0 | 2.58 | 119.0 | 232.0 | 1.95 | 119.0 | 263.0 | 2.21 | 505.0 | 1483.0 | 2.94 | 588.0 | 1772.0 | 3.01 | 857.0 | 1794.0 | 2.09 | 842.0 | 2181.0 | 2.59 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2016 | 145 | 3 | 6805.0 | 16399.0 | 2.41 | 1139.0 | 2590.0 | 2.27 | 710.0 | 1587.0 | 2.24 | 848.0 | 1989.0 | 2.35 | 624.0 | 1813.0 | 2.91 | 459.0 | 1311.0 | 2.86 | 126.0 | 244.0 | 1.94 | 99.0 | 242.0 | 2.44 | 101.0 | 235.0 | 2.33 | 196.0 | 419.0 | 2.14 | 606.0 | 1752.0 | 2.89 | 899.0 | 1928.0 | 2.14 | 998.0 | 2289.0 | 2.29 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2015 | 145 | 3 | 5634.0 | 15593.0 | 2.77 | 952.0 | 2620.0 | 2.75 | 855.0 | 2468.0 | 2.89 | 534.0 | 1546.0 | 2.90 | 638.0 | 1883.0 | 2.95 | 342.0 | 996.0 | 2.91 | 114.0 | 269.0 | 2.36 | 112.0 | 220.0 | 1.96 | 93.0 | 219.0 | 2.35 | 53.0 | 59.0 | 1.11 | 599.0 | 1610.0 | 2.69 | 655.0 | 1679.0 | 2.56 | 687.0 | 2024.0 | 2.95 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2014 | 145 | 3 | 5354.0 | 15123.0 | 2.82 | 986.0 | 2448.0 | 2.48 | 719.0 | 2128.0 | 2.96 | 631.0 | 2070.0 | 3.28 | 453.0 | 1442.0 | 3.18 | 445.0 | 1211.0 | 2.72 | 90.0 | 207.0 | 2.30 | 108.0 | 236.0 | 2.19 | 99.0 | 200.0 | 2.02 | 75.0 | 130.0 | 1.73 | 195.0 | 412.0 | 2.11 | 617.0 | 1876.0 | 3.04 | 936.0 | 2763.0 | 2.95 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2013 | 145 | 3 | 6428.0 | 17043.0 | 2.65 | 877.0 | 2289.0 | 2.61 | 1098.0 | 2315.0 | 2.11 | 970.0 | 2828.0 | 2.92 | 563.0 | 1704.0 | 3.03 | 492.0 | 1192.0 | 2.42 | 156.0 | 398.0 | 2.55 | 102.0 | 254.0 | 2.49 | 126.0 | 247.0 | 1.96 | 141.0 | 395.0 | 2.80 | 438.0 | 1312.0 | 3.00 | 787.0 | 1825.0 | 2.32 | 678.0 | 2284.0 | 3.37 | |||||||||||||||||||||||||
1122 | Luft/Wasser | Rotex HSPU bi-block | 16.0 | 2012 | 145 | 3 | 6630.0 | 12470.0 | 2.07 | 615.0 | 1105.0 | 1599.0 | 1.45 | 930.0 | 2114.0 | 2.27 | 655.0 | 1831.0 | 2.80 | 560.0 | 1266.0 | 2.26 | 253.0 | 935.0 | 3.70 | 237.0 | 328.0 | 1.38 | 220.0 | 186.0 | 0.85 | 222.0 | 202.0 | 0.91 | 220.0 | 144.0 | 0.65 | 728.0 | 1402.0 | 1.93 | 885.0 | 2463.0 | 2.78 |
NR | 1122 |
Username | Atze1503 |
Einbaujahr der WP | 2010-06-28 |
PLZ des Wohnortes | 34576 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Rotex HSPU bi-block |
modulierend | |
Leistung (0/35) | 16.0 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH und Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 145 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |