Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2021 | 200 | 2 | 3471.0 | 13314.0 | 819 | 3.84 | 1090.0 | 4131.0 | 256 | 3.79 | 889.0 | 3365.0 | 209 | 3.79 | 803.0 | 3173.0 | 191 | 3.95 | 604.0 | 2339.0 | 145 | 3.87 | 85.0 | 306.0 | 18 | 3.60 | ||||||||||||||||||||||||||||||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2020 | 200 | 2 | 5142.0 | 19069.0 | 1147 | 3.71 | 822.0 | 2687.0 | 162 | 3.27 | 890.0 | 2842.0 | 176 | 3.19 | 534.0 | 2020.0 | 127 | 3.78 | 319.0 | 1242.0 | 77 | 3.89 | 220.0 | 858.0 | 52 | 3.90 | 68.0 | 248.0 | 15 | 3.65 | 0 | 0 | 0 | 0 | 0 | 0 | 148.0 | 595.0 | 35 | 4.02 | 472.0 | 2036.0 | 111 | 4.31 | 724.0 | 2870.0 | 170 | 3.96 | 945.0 | 3671.0 | 222 | 3.88 | ||||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2019 | 200 | 2 | 5577.4 | 19127.4 | 1162 | 3.43 | 860.0 | 3032.0 | 199 | 3.53 | 778.0 | 2817.0 | 183 | 3.62 | 667.0 | 2479.0 | 157 | 3.72 | 250.0 | 916.0 | 57 | 3.66 | 244.0 | 907.0 | 56 | 3.72 | 66.3 | 149.9 | 11 | 2.26 | 62.0 | 112.0 | 7 | 1.81 | 74.0 | 146.9 | 10 | 1.99 | 241.2 | 886.6 | 54 | 3.68 | 326.0 | 1137.0 | 66 | 3.49 | 920.9 | 3110.0 | 165 | 3.38 | 1088.0 | 3434.0 | 197 | 3.16 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2018 | 200 | 2 | 5075.6 | 18167.5 | 1159 | 3.58 | 667.0 | 2433.0 | 156 | 3.65 | 1008.0 | 3615.0 | 235 | 3.59 | 811.0 | 2961.0 | 191 | 3.65 | 151.0 | 535.7 | 35 | 3.55 | 119.0 | 351.0 | 23 | 2.95 | 69.0 | 134.0 | 9 | 1.94 | 69.0 | 109.0 | 8 | 1.58 | 54.0 | 103.0 | 7 | 1.91 | 165.0 | 574.0 | 36 | 3.48 | 334.6 | 1169.8 | 77 | 3.50 | 736.0 | 2869.0 | 172 | 3.90 | 892.0 | 3313.0 | 210 | 3.71 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2017 | 200 | 2 | 5250.8 | 19663.4 | 1220 | 3.74 | 1118.1 | 4197.1 | 264 | 3.75 | 739.0 | 2829.0 | 177 | 3.83 | 538.0 | 2070.0 | 128 | 3.85 | 453.0 | 1745.0 | 108 | 3.85 | 174.1 | 633.1 | 39 | 3.64 | 70.0 | 125.0 | 9 | 1.79 | 36.8 | 66.8 | 4 | 1.82 | 67.0 | 125.0 | 9 | 1.87 | 223.0 | 914.0 | 39 | 4.10 | 260.0 | 976.0 | 73 | 3.75 | 726.0 | 2794.0 | 170 | 3.85 | 845.8 | 3188.4 | 200 | 3.77 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2016 | 200 | 2 | 5243.5 | 19693.9 | 1216 | 3.76 | 745.4 | 2854.8 | 176 | 3.83 | 778.4 | 2985.0 | 185 | 3.83 | 639.2 | 2428.7 | 151 | 3.80 | 453.0 | 1712.0 | 106 | 3.78 | 182.8 | 640.7 | 41 | 3.50 | 53.0 | 148.0 | 10 | 2.79 | 71.2 | 145.5 | 10 | 2.04 | 56.4 | 119.1 | 8 | 2.11 | 144.7 | 470.8 | 29 | 3.25 | 376.0 | 1486.0 | 89 | 3.95 | 758.5 | 2971.0 | 180 | 3.92 | 984.9 | 3732.3 | 231 | 3.79 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2015 | 200 | 2 | 4916.0 | 18418.0 | 1134 | 3.75 | 880.0 | 3407.0 | 209 | 3.87 | 839.0 | 3185.0 | 199 | 3.80 | 645.0 | 2500.0 | 155 | 3.88 | 377.0 | 1431.0 | 88 | 3.80 | 178.0 | 616.0 | 39 | 3.46 | 60.0 | 141.0 | 10 | 2.35 | 70.0 | 106.0 | 7 | 1.51 | 83.0 | 138.0 | 10 | 1.66 | 193.0 | 723.0 | 44 | 3.75 | 342.0 | 1324.0 | 80 | 3.87 | 556.0 | 2159.0 | 130 | 3.88 | 693.0 | 2688.0 | 163 | 3.88 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2014 | 200 | 2 | 4217.0 | 15932.0 | 980 | 3.78 | 603.0 | 2350.0 | 145 | 3.90 | 645.0 | 2555.0 | 158 | 3.96 | 524.0 | 2000.0 | 124 | 3.82 | 261.0 | 970.0 | 61 | 3.72 | 197.0 | 690.0 | 43 | 3.50 | 77.0 | 161.0 | 11 | 2.09 | 75.0 | 109.0 | 8 | 1.45 | 102.0 | 300.0 | 19 | 2.94 | 132.0 | 449.0 | 28 | 3.40 | 214.0 | 841.0 | 50 | 3.93 | 583.0 | 2328.0 | 140 | 3.99 | 804.0 | 3179.0 | 193 | 3.95 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2013 | 200 | 2 | 5373.6 | 20308.4 | 1255 | 3.78 | 922.0 | 3494.0 | 217 | 3.79 | 922.0 | 3494.0 | 217 | 3.79 | 729.0 | 2700.0 | 162 | 3.70 | 369.0 | 1366.0 | 86 | 3.70 | 312.0 | 1163.0 | 73 | 3.73 | 75.0 | 265.0 | 18 | 3.53 | 75.0 | 265.0 | 18 | 3.53 | 75.0 | 265.0 | 18 | 3.53 | 220.0 | 775.0 | 47 | 3.52 | 267.6 | 1032.6 | 63 | 3.86 | 665.5 | 2609.1 | 159 | 3.92 | 741.5 | 2879.7 | 177 | 3.88 | ||||||||||||
1194 | Wasser/Wasser | Bartl WB 6 CF / W - V | 16.5 | 2012 | 200 | 2 | 5124.0 | 9999.9 | 1248 | 1.95 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5124.0 | 9999.9 | 1248 | 1.95 |
NR | 1194 |
Username | henner1 |
Einbaujahr der WP | 2011-09-25 |
PLZ des Wohnortes | 63500 |
Bauart | Wasser/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Bartl WB 6 CF / W - V |
modulierend | |
Leistung (0/35) | 16.5 kW |
berechneter Primärenergiebedarf | 100.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Förder- und Schluckbrunnen |
Tiefe | 10.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 3450 Watt gem. |
elektr. Verbrauch HP gem./DB | 100 Watt |
elektr. Verbrauch WQ P gem./DB | 650 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 24.0 °C |
Mittlere Wärmequellentemperatur | 12.0 °C |
Heizung max. Vorlauf Temp. | 40.0 °C |
Spreizung Heizkr. | 7.7 |
Heizflaeche | 200 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Heizleistung EN 14511 lt. Hersteller 18,6 kW, im Versuch ermittelt nur 16,5 kW (gemäß EN14511). Die Dezemberzahlen von 2012 sind Jahreszahlen. Die "AZ" ist im Sommer mager wegen Passivkühlung bis Ende 2018. Ab 2019 Warmwasser nicht mehr mit dieser WP und im Sommer keine Werte mehr, da AZ verfälscht wird. |