| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2023 | 130 | 2511.0 | * | 947.0 | 905.0 | 659.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2022 | 130 | 2 | 1188.0 | * | 1188.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2016 | 130 | 3 | 2984.0 | * | 986.0 | 711.0 | 580.0 | 343.0 | 146.0 | 69.0 | 64.0 | 85.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2015 | 130 | 3 | 4397.0 | * | 775.0 | 774.0 | 537.0 | 355.0 | 176.0 | 101.0 | 58.0 | 72.0 | 172.0 | 395.0 | 469.0 | 513.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2014 | 130 | 3 | 4350.0 | * | 967.0 | 564.0 | 399.0 | 222.0 | 203.0 | 99.0 | 60.0 | 93.0 | 122.0 | 228.0 | 498.0 | 895.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 1255 | Luft/Wasser | NIBE F750E | 6.0 | 2013 | 130 | 3 | 1228.0 | * | 525.0 | 703.0 |
| NR | 1255 |
| Username | MaxiKG2 |
| Einbaujahr der WP | 2013-10-22 |
| PLZ des Wohnortes | 01558 |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | NIBE F750E |
| modulierend | |
| Leistung (0/35) | 6.0 kW |
| berechneter Primärenergiebedarf | 55.8 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | wöchentlich |
| WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 2000 Watt DB |
| elektr. Verbrauch HP gem./DB | 55 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
| WMZ | |
| Mittlere Raumtemp. | 23.0 °C |
| Mittlere Wärmequellentemperatur | 0.0 °C |
| Heizung max. Vorlauf Temp. | 45.0 °C |
| Spreizung Heizkr. | 10.0 |
| Heizflaeche | 130 m² |
| Lüftung | zenKWLWR |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen | Okt 2013 F600P durch F750E ersetzt. FBH EG, HK im OG, kein Keller. |