Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2023 | 140 | 4 | 5625.0 | 16989.0 | 3.02 | 407.0 | 722.0 | 1.77 | 1157.0 | 3216.0 | 2.78 | 988.0 | 3106.0 | 3.14 | 786.0 | 2580.0 | 3.28 | 435.0 | 1580.0 | 3.63 | 86.0 | 289.0 | 3.36 | 99.0 | 371.0 | 3.75 | 75.0 | 210.0 | 2.80 | 159.0 | 512.0 | 3.22 | 470.0 | 1573.0 | 3.35 | 963.0 | 2830.0 | 2.94 | ||||||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2022 | 140 | 4 | 7841.0 | 24108.0 | 3.07 | 1383.0 | 4010.0 | 2.90 | 1152.0 | 3403.0 | 2.95 | 1250.0 | 3592.0 | 2.87 | 778.0 | 2489.0 | 3.20 | 256.0 | 943.0 | 3.68 | 83.0 | 303.0 | 3.65 | 116.0 | 408.0 | 3.52 | 75.0 | 210.0 | 2.80 | 266.0 | 919.0 | 3.45 | 370.0 | 1418.0 | 3.83 | 830.0 | 2738.0 | 3.30 | 1282.0 | 3675.0 | 2.87 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2021 | 140 | 4 | 8626.0 | 27170.0 | 3.15 | 990.0 | 2693.0 | 2.72 | 1100.0 | 3550.0 | 3.23 | 1167.0 | 3585.0 | 3.07 | 990.0 | 3256.0 | 3.29 | 497.0 | 1828.0 | 3.68 | 214.0 | 832.0 | 3.89 | 85.0 | 323.0 | 3.80 | 161.0 | 629.0 | 3.91 | 313.0 | 1152.0 | 3.68 | 714.0 | 2341.0 | 3.28 | 1028.0 | 3245.0 | 3.16 | 1367.0 | 3736.0 | 2.73 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2020 | 140 | 4 | 8439.0 | 26745.0 | 3.17 | 1441.0 | 4122.0 | 2.86 | 1106.0 | 3546.0 | 3.21 | 1090.0 | 3489.0 | 3.20 | 532.0 | 1874.0 | 3.52 | 497.0 | 1828.0 | 3.68 | 245.0 | 799.0 | 3.26 | 78.0 | 270.0 | 3.46 | 131.0 | 453.0 | 3.46 | 220.0 | 780.0 | 3.55 | 704.0 | 2364.0 | 3.36 | 1042.0 | 3285.0 | 3.15 | 1353.0 | 3935.0 | 2.91 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2019 | 140 | 4 | 7550.0 | 25610.0 | 3.39 | 1324.0 | 3922.0 | 2.96 | 1014.0 | 3227.0 | 3.18 | 920.0 | 3171.0 | 3.45 | 625.0 | 2432.0 | 3.89 | 472.0 | 1890.0 | 4.00 | 98.0 | 380.0 | 3.88 | 73.0 | 285.0 | 3.90 | 96.0 | 377.0 | 3.93 | 290.0 | 1230.0 | 4.24 | 548.0 | 2126.0 | 3.88 | 828.0 | 2849.0 | 3.44 | 1262.0 | 3721.0 | 2.95 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2018 | 140 | 4 | 7464.0 | 23563.0 | 3.16 | 1250.0 | 3641.0 | 2.91 | 1077.0 | 3012.0 | 2.80 | 1177.0 | 3463.0 | 2.94 | 474.0 | 1778.0 | 3.75 | 181.0 | 733.0 | 4.05 | 100.0 | 389.0 | 3.89 | 79.0 | 301.0 | 3.81 | 130.0 | 537.0 | 4.13 | 256.0 | 1010.0 | 3.95 | 516.0 | 2044.0 | 3.96 | 876.0 | 2860.0 | 3.26 | 1348.0 | 3795.0 | 2.82 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2017 | 140 | 4 | 6460.0 | 22196.0 | 3.44 | 881.0 | 2320.0 | 2.63 | 1031.0 | 3288.0 | 3.19 | 749.0 | 2869.0 | 3.83 | 564.0 | 2276.0 | 4.04 | 294.0 | 1302.0 | 4.43 | 94.0 | 375.0 | 3.99 | 62.0 | 239.0 | 3.85 | 83.0 | 323.0 | 3.89 | 311.0 | 1377.0 | 4.43 | 542.0 | 2099.0 | 3.87 | 961.0 | 3088.0 | 3.21 | 888.0 | 2640.0 | 2.97 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2016 | 140 | 4 | 6049.0 | 21969.0 | 3.63 | 1078.0 | 3372.0 | 3.13 | 702.0 | 2454.0 | 3.50 | 746.0 | 2830.0 | 3.79 | 457.0 | 1904.0 | 4.17 | 293.0 | 1325.0 | 4.52 | 114.0 | 458.0 | 4.02 | 79.0 | 308.0 | 3.90 | 99.0 | 392.0 | 3.96 | 155.0 | 657.0 | 4.24 | 498.0 | 2144.0 | 4.31 | 734.0 | 2689.0 | 3.66 | 1094.0 | 3436.0 | 3.14 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2015 | 140 | 4 | 5548.0 | 19990.0 | 3.60 | 891.0 | 3046.0 | 3.42 | 890.0 | 2886.0 | 3.24 | 860.0 | 3088.0 | 3.59 | 399.0 | 1501.0 | 3.76 | 249.0 | 1015.0 | 4.08 | 110.0 | 407.0 | 3.70 | 72.0 | 276.0 | 3.83 | 83.0 | 320.0 | 3.86 | 194.0 | 859.0 | 4.43 | 408.0 | 1759.0 | 4.31 | 610.0 | 2309.0 | 3.79 | 782.0 | 2524.0 | 3.23 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2014 | 140 | 4 | 5826.0 | 21102.0 | 3.62 | 1044.0 | 3374.0 | 3.23 | 992.0 | 3156.0 | 3.18 | 608.0 | 2341.0 | 3.85 | 440.0 | 1851.0 | 4.21 | 294.0 | 1243.0 | 4.23 | 123.0 | 478.0 | 3.89 | 76.0 | 248.0 | 3.26 | 137.0 | 546.0 | 3.99 | 174.0 | 747.0 | 4.29 | 365.0 | 1533.0 | 4.20 | 614.0 | 2390.0 | 3.89 | 959.0 | 3195.0 | 3.33 | |||||||||||||||||||||||||
1274 | Luft/Wasser | Remko WKF 120 | 9.6 | 2013 | 140 | 4 | 2202.0 | 7963.0 | 3.62 | 68.0 | 234.0 | 3.44 | 75.0 | 230.0 | 3.07 | 192.0 | 853.0 | 4.44 | 324.0 | 1481.0 | 4.57 | 573.0 | 2300.0 | 4.01 | 970.0 | 2865.0 | 2.95 |
NR | 1274 |
Username | mfgkra |
Einbaujahr der WP | 2013-06-30 |
PLZ des Wohnortes | 8102 A |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Remko WKF 120 |
modulierend | Ja |
Leistung (0/35) | 9.6 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | Radiatoren |
elektr. Verbrauch WP ohne NA gem./DB | 2 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 140 m² |
Lüftung | Fenster |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Heizleistung bei A7/W35 |