Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2018 | 460 | 15-16 | 5877.7 | * | 1301.2 | 1755.9 | 1414.1 | 710.2 | 407.4 | 288.9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2017 | 460 | 15-16 | 9844.0 | 33460.3* | 3.40 | 1777.9 | 4617.0 | 3.19 | 1229.6 | 2969.0 | 3.27 | 1089.9 | 2524.0 | 3.28 | 1062.1 | 2482.0 | 3.33 | 645.2 | 1139.0 | 3.39 | 286.5 | 0.1 | 3.67 | 261.1 | 0.1 | 4.02 | 244.8 | 0.1 | 4.29 | 372.6 | 273.0 | 3.55 | 607.0 | 1013.0 | 3.40 | 1041.3 | 2400.0 | 3.31 | 1226.0 | 3443.0 | 3.66 | |||||||||||||||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2016 | 460 | 16 | 10450.4 | 34390.1* | 3.29 | 1344.6 | 3055.0 | 3.11 | 1362.3 | 3140.0 | 3.13 | 1337.5 | 3125.0 | 3.17 | 934.8 | 1940.0 | 3.27 | 667.7 | 1190.0 | 3.46 | 361.1 | 0.1 | 3.10 | 500.2 | 430.0 | 3.10 | 358.0 | 300.0 | 3.97 | 318.8 | 205.0 | 4.16 | 779.5 | 1800.0 | 3.75 | 1102.4 | 2510.0 | 3.29 | 1383.5 | 3255.0 | 3.16 | |||||||||||||||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2015 | 460 | 16 | 9882.9 | 31962.7* | 3.23 | 1622.1 | 3633.3 | 2.93 | 1497.1 | 3351.3 | 2.99 | 1207.7 | 2656.5 | 3.13 | 776.5 | 1387.8 | 3.23 | 590.6 | 842.4 | 3.32 | 415.3 | 154.9 | 3.07 | 455.4 | 500.0 | 3.56 | 275.4 | 0.1 | 4.07 | 437.6 | 477.9 | 3.65 | 726.2 | 1386.7 | 3.45 | 928.5 | 2029.5 | 3.39 | 950.5 | 2102.3 | 3.39 | |||||||||||||||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2014 | 460 | 16 | 8859.1 | 30240.3* | 3.41 | 1230.1 | 3030.0 | 3.37 | 1094.4 | 2800.0 | 3.58 | 1031.8 | 2500.0 | 3.51 | 662.6 | 1140.0 | 3.41 | 620.0 | 950.0 | 3.34 | 421.2 | 90.0 | 2.87 | 330.4 | 0.1 | 3.39 | 330.7 | 0.1 | 3.39 | 343.0 | 0.1 | 3.27 | 562.4 | 820.0 | 3.45 | 882.9 | 2010.0 | 3.55 | 1349.6 | 3460.0 | 3.39 | |||||||||||||||||||||||||
1287 | Luft/Wasser | Panasonic - SDC16C9E8 | 13.0 | 2013 | 460 | 14 | 3077.6 | 10400.7* | 3.38 | 691.3 | 1305.7 | 3.31 | 1090.5 | 2703.0 | 3.38 | 1295.8 | 3452.0 | 3.42 |
NR | 1287 |
Username | Chappi25 |
Einbaujahr der WP | 2013-09-12 |
PLZ des Wohnortes | 40468 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Panasonic - SDC16C9E8 |
modulierend | |
Leistung (0/35) | 13.0 kW |
berechneter Primärenergiebedarf | 50.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 3.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 4800 Watt gem. |
elektr. Verbrauch HP gem./DB | 180 Watt |
elektr. Verbrauch WQ P gem./DB | 40 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 460 m² |
Lüftung | zenKWLWR |
Personen | 15 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Mehrfamilienhaus Bj 2013; Wandaufbau: 11,5cm Klinker/-/2cm Luft/-/10cm Wolle 035/-/17,5cm KS; 3fach Verglasung U-Wert=0,6; Aufsparrendämmung 16cm PUR 024, 1000 Liter WW Hygienespeicher, 800 l Hzg Puffer, kontrollierte Wohnraumlüftung ohne Erdwärmekollektor, kein zentraler WMZ und Betriebsstundenzähler (allerdings pro Wohnung WMZ) Bei warmen Wetter läuft im Sommer Kühlbetrieb |