Verbrauchsdaten fuer Anlage Nr. 1314
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 2 | 1835 | 8486 | 4.62 | 1023 | 4485 | 4.38 | 363 | 1786 | 4.92 | 336 | 1628 | 4.85 | 113 | 587 | 5.18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||
| 2025 | 2 | 3566 | 16094 | 4.51 | 831 | 3644 | 4.39 | 585 | 2635 | 4.50 | 397 | 1890 | 4.76 | 132 | 630 | 4.77 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 326 | 1499 | 4.60 | 568 | 2585 | 4.55 | 727 | 3211 | 4.42 | |||||
| 2024 | 2 | 3249 | 15014 | 4.62 | 908 | 4145 | 4.56 | 454 | 2094 | 4.61 | 151 | 725 | 4.80 | 196 | 990 | 5.05 | 12 | 66 | 5.50 | 0 | 0 | 0 | 0 | 0 | 0 | 83 | 360 | 4.34 | 114 | 583 | 5.11 | 543 | 2578 | 4.75 | 788 | 3473 | 4.41 | |||
| 2023 | 2 | 2899 | 13541 | 4.67 | 697 | 3183 | 4.57 | 552 | 2459 | 4.45 | 335 | 1610 | 4.81 | 155 | 765 | 4.94 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8 | 40 | 5.00 | 103 | 539 | 5.23 | 424 | 2065 | 4.87 | 625 | 2880 | 4.61 | ||||
| 2022 | 2 | 2938 | 13555 | 4.61 | 760 | 3405 | 4.48 | 436 | 2109 | 4.84 | 340 | 1586 | 4.66 | 158 | 770 | 4.87 | 0 | 0 | 194 | 886 | 4.57 | 34 | 161 | 4.74 | 355 | 1770 | 4.99 | 661 | 2868 | 4.34 | ||||||||||
| 2021 | 2 | 3987 | 18197 | 4.56 | 941 | 4111 | 4.37 | 744 | 3761 | 5.06 | 486 | 1777 | 3.66 | 238 | 1160 | 4.87 | 164 | 774 | 4.72 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 223 | 1053 | 4.72 | 579 | 2693 | 4.65 | 612 | 2868 | 4.69 | ||||
| 2020 | 2 | 3302 | 15766 | 4.77 | 730 | 3353 | 4.59 | 486 | 2332 | 4.80 | 383 | 1853 | 4.84 | 60 | 257 | 4.28 | 56 | 232 | 4.14 | 0 | 0 | 0 | 0 | 0 | 0 | 90 | 520 | 5.78 | 212 | 1282 | 6.05 | 547 | 2530 | 4.63 | 738 | 3407 | 4.62 | |||
| 2019 | 2 | 3922 | 17896 | 4.56 | 976 | 4135 | 4.24 | 579 | 2559 | 4.42 | 465 | 2198 | 4.73 | 275 | 1325 | 4.82 | 151 | 754 | 5.00 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 181 | 937 | 5.18 | 604 | 2834 | 4.69 | 691 | 3154 | 4.56 | ||||
| 2018 | 2 | 3837 | 17332 | 4.52 | 646 | 3117 | 4.83 | 778 | 3289 | 4.23 | 704 | 3183 | 4.52 | 94 | 434 | 4.62 | 24 | 121 | 5.04 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 255 | 1213 | 4.76 | 659 | 2996 | 4.55 | 678 | 2979 | 4.39 | ||||
| 2017 | 2 | 4062 | 18152 | 4.47 | 1138 | 4642 | 4.08 | 581 | 2437 | 4.19 | 363 | 1784 | 4.92 | 284 | 1336 | 4.70 | 65 | 316 | 4.86 | 0 | 0 | 0 | 0 | 0 | 0 | 44 | 240 | 5.45 | 216 | 1072 | 4.96 | 597 | 2794 | 4.68 | 774 | 3531 | 4.56 | |||
| 2016 | 2 | 4685 | 21456 | 4.58 | 844 | 3767 | 4.46 | 680 | 3125 | 4.60 | 628 | 2897 | 4.61 | 364 | 1794 | 4.93 | 121 | 560 | 4.63 | 0 | 0 | 0 | 0 | 0 | 0 | 19 | 84 | 4.42 | 387 | 1955 | 5.05 | 676 | 3089 | 4.57 | 966 | 4185 | 4.33 | |||
| 2015 | 2 | 3556 | 16779 | 4.72 | 801 | 3702 | 4.62 | 764 | 3441 | 4.50 | 455 | 2229 | 4.90 | 210 | 979 | 4.66 | 64 | 279 | 4.36 | 0 | 0 | 0 | 0 | 0 | 0 | 41 | 169 | 4.12 | 274 | 1405 | 5.13 | 409 | 1968 | 4.81 | 538 | 2607 | 4.85 | |||
| 2014 | 2 | 3399 | 15088 | 4.44 | 743 | 3434 | 4.62 | 545 | 2564 | 4.70 | 415 | 1836 | 4.42 | 151 | 782 | 5.18 | 89 | 369 | 4.15 | 53 | 0 | 54 | 0 | 55 | 0 | 46 | 0 | 105 | 544 | 5.18 | 417 | 2133 | 5.12 | 726 | 3426 | 4.72 | ||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1314
Username
armin273
Gebäude Daten
PLZ
79206
Heizfläche (m²)
210
Wärmeübertragung
FBH
Raumtemperatur (°C)
22.0
Lüftung
Fenster
Endenergiebedarf (kWh/m²/anno)
berechnet nach Norm
Wärmepumpe Daten
Hersteller / Typ
LA12TU
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
9.4
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Nein
Einbaudatum
2012-09-15
Wärmepumpe Leistungsaufnahme (W)
2682 DB
Umwälzpumpe Leistungsaufnahme (W)
25 gem.
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
37.0
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
60 DB
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Nein
über WMZ erfasst
Nein
Temp (°C)
50
Legionellenschaltung
Nein
Zähler
Stromzähler
extern_geeicht
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
Altbau BJ 1937,Fussbodenheizung komplett,Fenster 90er Jahre,Dachsanierung KFW standard 2012
ab Oktober 14 ohne Warmwasser
Links