Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1330 | Luft/Wasser | Viessmann Vitocal 200-S | 7.7 | 2017 | 139 | 2 | 2989.0 | 625.0 | 367.0 | 290.0 | 271.0 | 120.0 | 81.0 | 137.0 | 95.0 | 82.0 | 141.0 | 342.0 | 438.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1330 | Luft/Wasser | Viessmann Vitocal 200-S | 7.7 | 2016 | 139 | 2 | 2791.0 | 509.0 | 420.0 | 349.0 | 117.0 | 89.0 | 54.0 | 105.0 | 99.0 | 61.0 | 189.0 | 326.0 | 473.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1330 | Luft/Wasser | Viessmann Vitocal 200-S | 7.7 | 2015 | 139 | 2 | 2675.0 | 459.0 | 487.0 | 361.0 | 213.0 | 117.0 | 36.0 | 161.0 | 81.0 | 82.0 | 106.0 | 243.0 | 329.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1330 | Luft/Wasser | Viessmann Vitocal 200-S | 7.7 | 2014 | 139 | 2 | 2818.0 | 508.0 | 355.0 | 367.0 | 216.0 | 117.0 | 55.0 | 81.0 | 86.0 | 73.0 | 111.0 | 354.0 | 495.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1330 | Luft/Wasser | Viessmann Vitocal 200-S | 7.7 | 2013 | 139 | 3773.0 | 650.0 | 650.0 | 637.0 | 264.0 | 139.0 | 105.0 | 109.0 | 81.0 | 103.0 | 99.0 | 448.0 | 488.0 |
NR | 1330 |
Username | ghost48 |
Einbaujahr der WP | 2012-10-25 |
PLZ des Wohnortes | 36100 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 200-S |
modulierend | |
Leistung (0/35) | 7.7 kW |
berechneter Primärenergiebedarf | 49.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 46 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 45.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 139 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Active Cooling aktiviert. Heizkennlinie: Bei 10 Grad = VL ?? / Bei 0 Grad = VL ?? / Bei -10 Grad = VL ?? / Bei -20 Grad = VL ?? |