Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1398 | Sole/Wasser | Vailant - Geotherm VWS 62/3 | 6.1 | 2016 | 145 | 2 | 1185.0 | 6100.0 | 776 | 5.15 | 271.0 | 1435.0 | 186 | 5.30 | 250.0 | 1323.0 | 171 | 5.29 | 231.0 | 1228.0 | 158 | 5.32 | 152.0 | 798.0 | 101 | 5.25 | 58.0 | 276.0 | 34 | 4.76 | 23.0 | 82.0 | 10 | 3.57 | 22.0 | 78.0 | 9 | 3.55 | 21.0 | 77.0 | 9 | 3.67 | 22.0 | 76.0 | 9 | 3.45 | 135.0 | 727.0 | 89 | 5.39 | ||||||||||||||||||||
1398 | Sole/Wasser | Vailant - Geotherm VWS 62/3 | 6.1 | 2015 | 145 | 2 | 1632.0 | 8522.0 | 1079 | 5.22 | 306.0 | 1613.0 | 209 | 5.27 | 266.0 | 1408.0 | 183 | 5.29 | 219.0 | 1168.0 | 150 | 5.33 | 144.0 | 759.0 | 95 | 5.27 | 74.0 | 374.0 | 46 | 5.05 | 29.0 | 114.0 | 13 | 3.93 | 22.0 | 80.0 | 10 | 3.64 | 22.0 | 79.0 | 9 | 3.59 | 23.0 | 83.0 | 9 | 3.61 | 139.0 | 751.0 | 92 | 5.40 | 176.0 | 947.0 | 119 | 5.38 | 212.0 | 1146.0 | 144 | 5.41 | ||||||||||||
1398 | Sole/Wasser | Vailant - Geotherm VWS 62/3 | 6.1 | 2014 | 145 | 2 | 793.0 | 4075.0 | 494 | 5.14 | 81.0 | 399.0 | 42 | 4.93 | 30.0 | 117.0 | 14 | 3.90 | 26.0 | 94.0 | 11 | 3.62 | 32.0 | 137.0 | 15 | 4.28 | 37.0 | 161.0 | 19 | 4.35 | 95.0 | 515.0 | 61 | 5.42 | 186.0 | 1018.0 | 124 | 5.47 | 306.0 | 1634.0 | 208 | 5.34 |
NR | 1398 |
Username | Resident |
Einbaujahr der WP | 2014-02-05 |
PLZ des Wohnortes | 54518 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Vailant - Geotherm VWS 62/3 |
modulierend | |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 53.8 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 1 Erdbohrung |
Tiefe | 99.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 20.0 °C |
Mittlere Wärmequellentemperatur | 7.5 °C |
Heizung max. Vorlauf Temp. | 32.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 145 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |