Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2024 | 156 | 2 | 2027.1 | 1103 | 495.2 | 277 | 282.8 | 152 | 243.1 | 131 | 106.7 | 59 | 7.4 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 17.8 | 8 | 123.9 | 66 | 332.5 | 181 | 417.7 | 227 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2023 | 156 | 2 | 2519.1 | 1419 | 505.0 | 293 | 475.1 | 275 | 382.8 | 215 | 269.0 | 156 | 49.2 | 28 | 0 | 0 | 0 | 0 | 2.4 | 1 | 0 | 0 | 113.7 | 60 | 311.0 | 168 | 410.9 | 223 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2022 | 156 | 2 | 2514.7 | 1421 | 467.6 | 263 | 448.4 | 262 | 302.3 | 164 | 290.2 | 163 | 9.4 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 62.2 | 34 | 89.9 | 48 | 337.4 | 195 | 507.3 | 288 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2021 | 156 | 2 | 2557.8 | 1449 | 478.6 | 267 | 424.4 | 251 | 294.5 | 165 | 205.7 | 113 | 83.3 | 45 | 0 | 0 | 0 | 0 | 0 | 0 | 35.0 | 19 | 177.6 | 97 | 336.9 | 191 | 521.8 | 301 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2020 | 156 | 2 | 2033.6 | 1112 | 433.8 | 236 | 344.3 | 186 | 311.3 | 176 | 104.3 | 56 | 74.5 | 39 | 3.5 | 2 | 0 | 0 | 0 | 0 | 13.0 | 9 | 126.9 | 68 | 250.4 | 136 | 371.6 | 204 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2019 | 156 | 2 | 2218.5 | 1211 | 538.2 | 296 | 316.2 | 170 | 296.2 | 160 | 113.1 | 61 | 92.0 | 48 | 0 | 0 | 0 | 0 | 0 | 0 | 18.2 | 9 | 122.8 | 70 | 314.3 | 175 | 407.5 | 222 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2018 | 156 | 2 | 2202.6 | 1199 | 401.5 | 217 | 461.9 | 255 | 395.8 | 219 | 77.1 | 40 | 23.7 | 11 | 0 | 0 | 0 | 0 | 0 | 0 | 15.4 | 8 | 121.2 | 65 | 304.6 | 166 | 401.4 | 218 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2017 | 156 | 2 | 2283.2 | 1239 | 543.5 | 306 | 356.5 | 195 | 218.2 | 118 | 169.8 | 92 | 47.1 | 18 | 0.4 | 0 | 0 | 0 | 0 | 0 | 49.2 | 26 | 129.5 | 67 | 330.0 | 178 | 439.0 | 239 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2016 | 156 | 2 | 2171.1 | 1183 | 449.0 | 249 | 343.1 | 187 | 309.0 | 168 | 141.0 | 77 | 26.6 | 15 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 168.8 | 89 | 329.6 | 178 | 404.0 | 220 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2015 | 156 | 2 | 1992.1 | 1073 | 420.6 | 227 | 369.4 | 201 | 292.7 | 157 | 167.1 | 90 | 20.0 | 11 | 6.6 | 3 | 0 | 0 | 0 | 0 | 4.8 | 3 | 192.5 | 103 | 246.4 | 132 | 272.0 | 146 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2014 | 156 | 2 | 1863.5 | 1009 | 458.9 | 255 | 276.3 | 149 | 211.4 | 115 | 82.2 | 45 | 57.5 | 32 | 0 | 0 | 0.6 | 0 | 0 | 0 | 5.6 | 3 | 83.2 | 43 | 246.8 | 131 | 441.0 | 236 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2013 | 156 | 2 | 2519.4 | 1415 | 483.3 | 285 | 445.3 | 261 | 464.7 | 260 | 189.6 | 104 | 61.3 | 33 | 27.5 | 15 | 0.1 | 0 | 0 | 0 | 40.3 | 21 | 119.1 | 64 | 302.2 | 164 | 386.0 | 208 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2012 | 156 | 2 | 2149.9 | 1256 | 398.1 | 228 | 536.1 | 333 | 188.1 | 107 | 171.7 | 98 | 18.9 | 11 | 9.7 | 5 | 0 | 0 | 0 | 0 | 5.6 | 3 | 154.0 | 87 | 247.9 | 138 | 419.8 | 246 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2011 | 156 | 2 | 1945.1 | 1109 | 432.0 | 247 | 405.7 | 233 | 247.0 | 141 | 77.8 | 44 | 20.1 | 12 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 121.7 | 70 | 280.7 | 161 | 360.1 | 201 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2010 | 156 | 2 | 2740.6 | 1597 | 635.3 | 379 | 415.1 | 241 | 287.1 | 165 | 138.7 | 80 | 89.0 | 51 | 11.4 | 7 | 0 | 0 | 3.7 | 2 | 49.8 | 28 | 177.2 | 101 | 303.6 | 174 | 629.7 | 369 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2009 | 156 | 2 | 2302.5 | 1324 | 569.8 | 337 | 437.8 | 248 | 315.0 | 177 | 52.3 | 30 | 25.3 | 14 | 21.4 | 12 | 0 | 0 | 0 | 0 | 10.9 | 6 | 185.4 | 105 | 214.6 | 121 | 470.0 | 274 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2008 | 156 | 2 | 2252.3 | 1270 | 363.5 | 204 | 323.1 | 182 | 324.9 | 184 | 191.4 | 108 | 11.6 | 7 | 0 | 0 | 0 | 0 | 0 | 0 | 75.4 | 43 | 176.7 | 99 | 327.2 | 183 | 458.5 | 260 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2007 | 156 | 2 | 1936.1 | 1099 | 346.6 | 196 | 302.5 | 172 | 232.1 | 133 | 60.6 | 34 | 10.7 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 47.2 | 27 | 168.9 | 95 | 341.6 | 194 | 425.9 | 242 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2006 | 156 | 2 | 2439.9 | 1394 | 641.4 | 361 | 546.8 | 324 | 399.7 | 228 | 149.7 | 86 | 25.7 | 15 | 30.0 | 17 | 0 | 0 | 3.5 | 2 | 0 | 0 | 71.4 | 40 | 236.9 | 132 | 334.8 | 189 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2005 | 156 | 2 | 2368.6 | 1265 | 436.1 | 225 | 466.3 | 248 | 361.9 | 192 | 136.6 | 71 | 62.0 | 33 | 21.0 | 11 | 2.6 | 1 | 5.2 | 3 | 4.7 | 3 | 62.2 | 33 | 306.0 | 164 | 504.0 | 281 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2004 | 156 | 2 | 2846.5 | 1498 | 593.7 | 325 | 458.9 | 249 | 388.0 | 211 | 165.0 | 83 | 90.1 | 44 | 18.0 | 9 | 7.2 | 4 | 0 | 0 | 56.6 | 28 | 155.4 | 78 | 412.5 | 209 | 501.1 | 258 | ||||||||||||||||||||||||||||||||||||||
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2003 | 156 | 3 | 2756.2 | 1481 | 589.7 | 325 | 530.3 | 283 | 284.0 | 145 | 200.9 | 105 | 27.6 | 14 | 0.7 | 0 | 0 | 0 | 0.1 | 0 | 29.6 | 15 | 289.4 | 156 | 310.4 | 168 | 493.5 | 270 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2002 | 156 | 3 | 2773.5 | 1557 | 545.2 | 313 | 350.4 | 199 | 359.8 | 204 | 232.9 | 132 | 56.1 | 32 | 3.5 | 2 | 0 | 0 | 0 | 0 | 70.7 | 39 | 246.7 | 135 | 352.7 | 194 | 555.5 | 307 | ||||||||||||||||||||||||||||||||||||||
14 | Luft/DK | ACALOR ZH26 (vorher NH56) | 7.2 | 2001 | 156 | 4 | 1226.4 | 726 | 98.0 | 56 | 117.0 | 77 | 407.0 | 238 | 604.4 | 355 |
NR | 14 |
Username | student |
Einbaujahr der WP | 2001-01-08 |
PLZ des Wohnortes | 04249 |
Bauart | Luft/DK |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | ACALOR ZH26 (vorher NH56) |
modulierend | Nein |
Leistung (0/35) | 7.2 kW |
berechneter Primärenergiebedarf | 43.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1800 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 2.8 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 156 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Im Fußbodenestrich direkt-kondensiernde LWP ACALOR, elektrisch 1,8 kW, thermisch 4,6 kW bei A-15/W35. Kompressor Mitsubishi NH56 am 21. 2. 2013 ersetzt durch Copeland ZH26. Reihenendhaus, mehrschalige Holzrahmenkonstruktion mit 24cm Hanfdämmung, k=0,19, n50=1,0/h, AN 183 m², ohne Keller, Neubau 2000, 3-fach Verglasung, getrennte Lüftung mit EWT + WRG, getrenntes Solarwarmwasser mit elektrischer Nacherwärmung. Wärmequellentemperatur an GT12-Heiztagen in 2001-2008 im ungewichteten Mittel 5,8°C, gewichtet über die Laufzeiten der WP 2,8°C. 8-Jahres-Mittel der Außen-Temperaturen 9,9°C. Kälterekord am 6. und 7. 1. 2009 mit min -22°C und max -16°C. Raumtemperatur sank auf 20°C. Kältester Monat war Jan. 2010 mit -4,8°C (Jan. 2009 -2,5°C) Mitteltemperatur. |