Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2024 | 160 | 4 | 1305.9 | 7189.0 | 411 | 6.38 | 418.0 | 2152.0 | 146 | 5.15 | 269.7 | 1598.0 | 93 | 5.93 | 246.2 | 1500.0 | 84 | 6.09 | 138.6 | 1188.0 | 37 | 8.57 | 54.0 | 751.0 | 11 | 13.91 | 51.0 | 0 | 13 | 36.7 | 0 | 8 | 47.0 | 0 | 11 | 44.7 | 0 | 8 | ||||||||||||||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2023 | 160 | 4 | 1882.5 | 11378.0 | 560 | 6.71 | 313.0 | 1814.0 | 108 | 5.80 | 272.6 | 1617.0 | 93 | 5.93 | 220.0 | 1603.0 | 72 | 7.29 | 113.4 | 1111.0 | 20 | 9.80 | 60.0 | 861.0 | 20 | 14.35 | 50.9 | 0 | 0 | 37.0 | 0 | 0 | 48.7 | 0 | 0 | 51.0 | 0 | 0 | 106.0 | 914.0 | 33 | 8.62 | 286.0 | 1635.0 | 99 | 5.72 | 323.9 | 1823.0 | 115 | 5.63 | ||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2022 | 160 | 4 | 2053.8 | 10954.0 | 665 | 6.06 | 372.0 | 2044.0 | 130 | 5.49 | 314.0 | 1761.0 | 110 | 5.61 | 285.0 | 1674.0 | 94 | 5.87 | 131.0 | 1178.0 | 36 | 8.99 | 53.3 | 662.0 | 18 | 12.42 | 48.0 | 0 | 12 | 33.0 | 0 | 10 | 40.9 | 0 | 9 | 58.0 | 0 | 7 | 67.0 | 0 | 14 | 264.0 | 1563.0 | 91 | 5.92 | 387.6 | 2072.0 | 134 | 5.35 | |||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2021 | 160 | 4 | 2841.0 | 14958.0 | 897 | 5.55 | 504.0 | 2519.0 | 117 | 5.00 | 438.0 | 2185.0 | 151 | 4.99 | 344.0 | 1952.0 | 119 | 5.67 | 298.0 | 1777.0 | 103 | 5.96 | 152.0 | 1112.0 | 46 | 7.32 | 50.0 | 669.0 | 13 | 13.38 | 51.0 | 0 | 14 | 45.0 | 0 | 11 | 52.0 | 0 | 13 | 188.0 | 1268.0 | 62 | 6.74 | 297.0 | 1268.0 | 103 | 4.27 | 422.0 | 2208.0 | 145 | 5.23 | |||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2020 | 160 | 4 | 2469.0 | 13627.0 | 833 | 6.02 | 384.0 | 2039.0 | 137 | 5.31 | 338.0 | 1874.0 | 118 | 5.54 | 294.0 | 1738.0 | 108 | 5.91 | 191.0 | 1363.0 | 56 | 7.14 | 122.0 | 1088.0 | 39 | 8.92 | 62.0 | 0 | 16 | 47.0 | 0 | 10 | 41.0 | 0 | 10 | 54.0 | 0 | 15 | 204.0 | 1337.0 | 66 | 6.55 | 307.0 | 1836.0 | 107 | 5.98 | 425.0 | 2352.0 | 151 | 5.53 | ||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2019 | 160 | 4 | 2642.0 | 13272.0 | 894 | 5.44 | 486.0 | 2336.0 | 172 | 4.81 | 334.0 | 1746.0 | 119 | 5.23 | 316.0 | 1730.0 | 112 | 5.47 | 207.0 | 1211.0 | 68 | 5.85 | 172.0 | 1145.0 | 56 | 6.66 | 61.0 | 0 | 16 | 34.0 | 0 | 0 | 45.0 | 0 | 8 | 63.0 | 0 | 17 | 201.0 | 1262.0 | 69 | 6.28 | 348.0 | 1824.0 | 124 | 5.24 | 375.0 | 2018.0 | 133 | 5.38 | ||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2018 | 160 | 4 | 2689.0 | 13517.0 | 913 | 5.38 | 444.0 | 2299.0 | 159 | 5.18 | 535.0 | 2435.0 | 185 | 4.55 | 392.0 | 2062.0 | 136 | 5.26 | 171.0 | 1183.0 | 54 | 6.92 | 77.0 | 568.0 | 22 | 7.38 | 44.0 | 0 | 10 | 34.0 | 0 | 8 | 39.0 | 0 | 10 | 61.0 | 0 | 17 | 161.0 | 1122.0 | 54 | 6.97 | 350.0 | 1839.0 | 123 | 5.25 | 381.0 | 2009.0 | 135 | 5.27 | ||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2017 | 160 | 4 | 2797.0 | 13959.0 | 910 | 5.33 | 615.0 | 2756.0 | 217 | 4.48 | 405.0 | 2014.0 | 136 | 4.97 | 263.0 | 1612.0 | 89 | 6.13 | 233.0 | 1499.0 | 80 | 6.43 | 197.0 | 902.0 | 28 | 4.58 | 41.0 | 0 | 10 | 41.0 | 0 | 11 | 48.0 | 0 | 12 | 49.0 | 0 | 13 | 157.0 | 1127.0 | 51 | 7.18 | 329.0 | 1855.0 | 116 | 5.64 | 419.0 | 2194.0 | 147 | 5.24 | ||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2016 | 160 | 4 | 2827.0 | 12880.0 | 926 | 4.78 | 476.0 | 1982.0 | 161 | 4.16 | 403.0 | 1664.0 | 134 | 4.13 | 419.0 | 1843.0 | 136 | 4.40 | 188.0 | 902.0 | 59 | 4.80 | 76.0 | 381.0 | 23 | 5.01 | 49.0 | 554.0 | 12 | 11.31 | 36.0 | 0 | 9 | 48.0 | 0 | 12 | 50.0 | 0 | 12 | 220.0 | 1311.0 | 72 | 5.96 | 420.0 | 2053.0 | 143 | 4.89 | 442.0 | 2190.0 | 153 | 4.95 | |||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2015 | 160 | 4 | 2504.3 | 11617.0 | 469 | 4.85 | 425.0 | 1927.0 | 4.53 | 375.0 | 1665.0 | 4.44 | 317.0 | 1420.0 | 102 | 4.48 | 221.3 | 1013.0 | 64 | 4.58 | 132.0 | 921.0 | 25 | 6.98 | 57.0 | 522.0 | 9.16 | 38.0 | 286.0 | 2 | 7.53 | 35.0 | 2 | 72.0 | 11 | 238.0 | 1117.0 | 73 | 4.69 | 271.0 | 1279.0 | 86 | 4.72 | 323.0 | 1467.0 | 104 | 4.54 | |||||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2014 | 160 | 4 | 2159.2 | 3216.0 | 4.51 | 416.0 | 317.0 | 262.0 | 114.0 | 56.0 | 42.0 | 45.0 | 45.7 | 38.5 | 110.0 | 313.0 | 1428.0 | 4.56 | 400.0 | 1788.0 | 4.47 | |||||||||||||||||||||||||||||||||||||||||||||
1412 | Sole/Wasser | tecalor TTF10 | 10.2 | 2013 | 160 | 4 | 656.0 | 307.0 | 349.0 |
NR | 1412 |
Username | HKMeyer |
Einbaujahr der WP | 2013-11-19 |
PLZ des Wohnortes | 28259 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | tecalor TTF10 |
modulierend | |
Leistung (0/35) | 10.2 kW |
berechneter Primärenergiebedarf | 48.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 52 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 100.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2030 Watt DB |
elektr. Verbrauch HP gem./DB | 72 Watt |
elektr. Verbrauch WQ P gem./DB | 130 Watt |
Stromzähler | extern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 9.0 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 160 m² |
Lüftung | dezKWL |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Nachrüstung/ Austausch einer Tecalor Lüftungsanlage THD 300SOL. Kontrollierte Entlüftung ohne Wärmerückgewinnung. 14.9.2016 Austausch Baugruppe für Umschaltventil nach längerer Fehlfunktion (Wärme im Heizkreislauf, bei Warmwasserbereitung) auf Garantie. |