Verbrauchsdaten fuer Anlage Nr. 1453
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 3 | 724 | 2842 | 3.92 | 339 | 1364 | 4.03 | 216 | 851 | 3.94 | 170 | 627 | 3.69 | |||||||||||||||||||||||||||
| 2025 | 3 | 1274 | 5017 | 3.94 | 256 | 1037 | 4.05 | 225 | 875 | 3.90 | 148 | 526 | 3.55 | 83 | 235 | 2.83 | 54 | 147 | 2.69 | 40 | 120 | 2.98 | 40 | 124 | 3.11 | 31 | 89 | 2.86 | 48 | 136 | 2.83 | 81 | 258 | 3.20 | 160 | 629 | 3.93 | 108 | 842 | 7.83 |
| 2024 | 3 | 1346 | 4523 | 3.36 | 255 | 1004 | 3.94 | 165 | 606 | 3.67 | 131 | 440 | 3.35 | 91 | 259 | 2.84 | 56 | 140 | 2.49 | 56 | 136 | 2.44 | 52 | 129 | 2.50 | 40 | 92 | 2.31 | 51 | 112 | 2.18 | 73 | 184 | 2.53 | 173 | 638 | 3.69 | 203 | 784 | 3.85 |
| 2023 | 3 | 1442 | 4983 | 3.46 | 247 | 975 | 3.95 | 209 | 792 | 3.80 | 172 | 621 | 3.62 | 129 | 430 | 3.33 | 71 | 176 | 2.47 | 47 | 119 | 2.53 | 39 | 91 | 2.37 | 46 | 117 | 2.55 | 47 | 116 | 2.50 | 67 | 176 | 2.65 | 156 | 566 | 3.64 | 214 | 804 | 3.75 |
| 2022 | 3 | 1602 | 5465 | 3.41 | 318 | 1186 | 3.74 | 233 | 853 | 3.67 | 183 | 633 | 3.46 | 134 | 453 | 3.37 | 72 | 179 | 2.49 | 52 | 134 | 2.58 | 41 | 100 | 2.46 | 44 | 112 | 2.53 | 58 | 142 | 2.46 | 66 | 160 | 2.41 | 131 | 457 | 3.48 | 271 | 1057 | 3.89 |
| 2021 | 3 | 2108 | 7072 | 3.35 | 332 | 1251 | 3.77 | 296 | 1050 | 3.55 | 244 | 830 | 3.40 | 195 | 645 | 3.31 | 125 | 330 | 2.64 | 61 | 148 | 2.43 | 56 | 131 | 2.37 | 69 | 165 | 2.38 | 72 | 177 | 2.45 | 130 | 396 | 3.04 | 211 | 739 | 3.50 | 318 | 1210 | 3.80 |
| 2020 | 3 | 1703 | 5575 | 3.27 | 258 | 991 | 3.83 | 205 | 762 | 3.72 | 189 | 649 | 3.44 | 103 | 280 | 2.72 | 83 | 213 | 2.57 | 59 | 127 | 2.14 | 54 | 123 | 2.26 | 63 | 143 | 2.28 | 73 | 173 | 2.37 | 127 | 368 | 2.90 | 204 | 692 | 3.40 | 285 | 1055 | 3.70 |
| 2019 | 3 | 1693 | 5734 | 3.39 | 330 | 1326 | 4.02 | 204 | 741 | 3.63 | 175 | 605 | 3.47 | 125 | 379 | 3.04 | 100 | 276 | 2.76 | 44 | 99 | 2.24 | 46 | 76 | 1.67 | 51 | 108 | 2.13 | 67 | 157 | 2.34 | 95 | 266 | 2.80 | 223 | 843 | 3.79 | 235 | 858 | 3.66 |
| 2018 | 3 | 1669 | 6486 | 3.89 | 272 | 1129 | 4.15 | 347 | 1409 | 4.07 | 251 | 993 | 3.95 | 82 | 295 | 3.58 | 59 | 207 | 3.50 | 36 | 107 | 2.96 | 33 | 100 | 3.03 | 25 | 68 | 2.71 | 47 | 139 | 2.97 | 87 | 307 | 3.52 | 203 | 817 | 4.03 | 227 | 914 | 4.04 |
| 2017 | 3 | 1881 | 7459 | 3.97 | 394 | 1607 | 4.08 | 262 | 1053 | 4.02 | 190 | 751 | 3.96 | 153 | 595 | 3.89 | 87 | 314 | 3.61 | 32 | 94 | 2.95 | 23 | 64 | 2.71 | 33 | 98 | 2.97 | 73 | 265 | 3.62 | 101 | 388 | 3.83 | 241 | 1019 | 4.23 | 293 | 1213 | 4.14 |
| 2016 | 3 | 1869 | 7438 | 3.98 | 290 | 1213 | 4.18 | 265 | 1079 | 4.08 | 250 | 1024 | 4.10 | 152 | 583 | 3.83 | 70 | 230 | 3.28 | 40 | 119 | 2.99 | 33 | 95 | 2.92 | 31 | 92 | 2.99 | 32 | 95 | 2.94 | 150 | 600 | 4.01 | 273 | 1139 | 4.18 | 284 | 1170 | 4.12 |
| 2015 | 3 | 1730 | 6453 | 3.73 | 411 | 1571 | 3.82 | 300 | 1150 | 3.83 | 211 | 723 | 3.43 | 99 | 253 | 2.56 | 45 | 132 | 2.93 | 34 | 102 | 2.98 | 37 | 115 | 3.14 | 74 | 257 | 3.46 | 150 | 624 | 4.16 | 176 | 733 | 4.16 | 193 | 792 | 4.11 | |||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1453
Username
rwams2002
Gebäude Daten
PLZ
48317
Heizfläche (m²)
143
Wärmeübertragung
FBH
Raumtemperatur (°C)
21.0
Lüftung
zenKWLWR
Endenergiebedarf (kWh/m²/anno)
30.0
berechnet nach Norm
EnEV2009
Wärmepumpe Daten
Hersteller / Typ
Junkers Supraeco STM 60-1
Bauart
Sole/Wasser
Heizleistung (kW) (0/35 2/35)
5.8
Betriebsart Mono/Bi/Tri-valent
Mono
Modulierend
Nein
Einbaudatum
2015-02-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
2 Erdbohrungen a
Tiefe (m)
65.0
Fläche (m²)
max. Vorlauftemperatur (°C)
30.0
Spreizung Heizkreise (°K)
5.0
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
45
Legionellenschaltung
Ja
Zähler
Stromzähler
extern
Stromzähler erfasst
Kompressor,Steuerung,Pumpen
Wärmemengenzähler
intern
Informationen
Bemerkungen
Links