| Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
| 1468 | Luft/Wasser | Daikin Altherma LT | 12.0 | 2016 | 99 | 2 | 535.0 | 2737.0* | 794 | 5.12 | 325.0 | 1491.0 | 521 | 5.02 | 210.0 | 966.0 | 273 | 5.27 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1468 | Luft/Wasser | Daikin Altherma LT | 12.0 | 2015 | 99 | 1734.0 | 7516.0* | 4073 | 4.33 | 491.0 | 1915.0 | 353 | 3.90 | 15.0 | 189.0 | 348 | 12.60 | 60.0 | 196.0 | 499 | 3.27 | 64.0 | 308.0 | 299 | 4.81 | 60.0 | 291.0 | 347 | 4.85 | 18.0 | 43.0 | 59 | 2.39 | 81.0 | 280.0 | 250 | 3.46 | 81.0 | 328.0 | 250 | 4.05 | 79.0 | 377.0 | 423 | 4.77 | 213.0 | 1004.0 | 197 | 4.71 | 252.0 | 1118.0 | 548 | 4.44 | 320.0 | 1467.0 | 500 | 4.58 | |||||||||||||
| 1468 | Luft/Wasser | Daikin Altherma LT | 12.0 | 2014 | 99 | 762.0 | 3049.0* | 925 | 4.00 | 67.0 | 230.0 | 525 | 3.43 | 60.0 | 383.0 | 100 | 6.38 | 387.0 | 1602.0 | 200 | 4.14 | 248.0 | 834.0 | 100 | 3.36 |
| NR | 1468 |
| Username | Downhill |
| Einbaujahr der WP | 2018-04-18 |
| PLZ des Wohnortes | 3994TZ |
| Bauart | Luft/Wasser |
| Mono-Bi-Tri Valent | Mono |
| Hersteller Typ | Daikin Altherma LT |
| modulierend | Ja |
| Leistung (0/35) | 12.0 kW |
| berechneter Primärenergiebedarf | 310.0 kWh/m²/anno |
| WW über WP | Ja |
| WW Temperatur | 50 °C |
| WW Legionellenschaltung | wekelijks |
| WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
| Quelle | Luft |
| Tiefe | 0.0 m |
| Fläche | 0 m² |
| Heizungsart | FBH |
| elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
| elektr. Verbrauch HP gem./DB | 0 Watt |
| elektr. Verbrauch WQ P gem./DB | 0 Watt |
| Stromzähler | > erfasst: |
| WMZ | |
| Mittlere Raumtemp. | 20.0 °C |
| Mittlere Wärmequellentemperatur | 35.0 °C |
| Heizung max. Vorlauf Temp. | 45.0 °C |
| Spreizung Heizkr. | 0.0 |
| Heizflaeche | 99 m² |
| Lüftung | zenKWL |
| Personen | 2 |
| Grabenkollektor Helfer | Nein |
| Grabenkollektor Erfahrung | |
| Bemerkungen |