Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1479 | Luft/Wasser | Viessmann Vitocal 200 AWBC | 5.6 | 2017 | 147 | 3 | 3621.0 | * | 904.0 | 466.0 | 304.0 | 276.0 | 134.0 | 86.0 | 80.0 | 66.0 | 98.0 | 208.0 | 432.0 | 567.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1479 | Luft/Wasser | Viessmann Vitocal 200 AWBC | 5.6 | 2016 | 147 | 3 | 2884.0 | * | 610.0 | 504.0 | 425.0 | 260.0 | 125.0 | 84.0 | 82.0 | 83.0 | 83.0 | 264.0 | 364.0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
1479 | Luft/Wasser | Viessmann Vitocal 200 AWBC | 5.6 | 2015 | 147 | 3 | 3321.0 | * | 660.0 | 673.0 | 400.0 | 230.0 | 106.0 | 82.0 | 68.0 | 68.0 | 92.0 | 207.0 | 355.0 | 380.0 | ||||||||||||||||||||||||||||||||||||||||||||||||||
1479 | Luft/Wasser | Viessmann Vitocal 200 AWBC | 5.6 | 2014 | 147 | 3 | 1662.0 | * | 103.0 | 95.0 | 112.0 | 167.0 | 207.0 | 373.0 | 605.0 |
NR | 1479 |
Username | JoMei |
Einbaujahr der WP | 2013-11-01 |
PLZ des Wohnortes | 67294 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Viessmann Vitocal 200 AWBC |
modulierend | |
Leistung (0/35) | 5.6 kW |
berechneter Primärenergiebedarf | 66.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 51 °C |
WW Legionellenschaltung | wöchentlich |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 147 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Wintereinstellung 2 und -1 bei 19 Grad Raumtemperatur |