Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2024 | 171 | 4 | 1464.0 | 3400.0 | 2.32 | 446.0 | 1200.0 | 2.69 | 235.0 | 600.0 | 2.55 | 193.0 | 400.0 | 2.07 | 150.0 | 300.0 | 2.00 | 96.0 | 200.0 | 2.08 | 80.0 | 200.0 | 2.50 | 102.0 | 200.0 | 1.96 | 60.0 | 100.0 | 1.67 | 102.0 | 200.0 | 1.96 | ||||||||||||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2023 | 171 | 4 | 2363.0 | 5400.0 | 2.29 | 357.0 | 900.0 | 2.52 | 338.0 | 900.0 | 2.66 | 264.0 | 500.0 | 1.89 | 213.0 | 300.0 | 1.41 | 105.0 | 200.0 | 1.90 | 80.0 | 200.0 | 2.50 | 77.0 | 100.0 | 1.30 | 88.0 | 200.0 | 2.27 | 61.0 | 100.0 | 1.64 | 127.0 | 200.0 | 1.57 | 298.0 | 800.0 | 2.68 | 355.0 | 1000.0 | 2.82 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2022 | 171 | 4 | 2204.0 | 5300.0 | 2.40 | 394.0 | 1100.0 | 2.79 | 265.0 | 600.0 | 2.26 | 258.0 | 700.0 | 2.71 | 168.0 | 300.0 | 1.79 | 94.0 | 200.0 | 2.13 | 60.0 | 100.0 | 1.67 | 76.0 | 200.0 | 2.63 | 68.0 | 100.0 | 1.47 | 91.0 | 200.0 | 2.20 | 98.0 | 100.0 | 1.02 | 237.0 | 600.0 | 2.53 | 395.0 | 1100.0 | 2.78 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2021 | 171 | 4 | 2578.0 | 6500.0 | 2.52 | 445.0 | 1300.0 | 2.92 | 344.0 | 900.0 | 2.62 | 269.0 | 700.0 | 2.60 | 181.0 | 300.0 | 1.66 | 136.0 | 400.0 | 2.94 | 75.0 | 100.0 | 1.33 | 75.0 | 200.0 | 2.67 | 72.0 | 100.0 | 1.39 | 84.0 | 200.0 | 2.38 | 199.0 | 300.0 | 1.51 | 321.0 | 900.0 | 2.80 | 377.0 | 1100.0 | 2.92 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2020 | 171 | 4 | 2408.0 | 5500.0 | 2.28 | 371.0 | 1000.0 | 2.70 | 291.0 | 700.0 | 2.41 | 240.0 | 600.0 | 2.50 | 133.0 | 200.0 | 1.50 | 116.0 | 300.0 | 2.59 | 86.0 | 100.0 | 1.16 | 84.0 | 200.0 | 2.38 | 68.0 | 100.0 | 1.47 | 104.0 | 200.0 | 1.92 | 198.0 | 300.0 | 1.52 | 324.0 | 700.0 | 2.16 | 393.0 | 1100.0 | 2.80 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2019 | 171 | 3 | 2349.0 | 5800.0 | 2.47 | 470.0 | 1400.0 | 2.98 | 314.0 | 800.0 | 2.55 | 242.0 | 600.0 | 2.48 | 129.0 | 200.0 | 1.55 | 102.0 | 200.0 | 1.96 | 58.0 | 100.0 | 1.72 | 67.0 | 100.0 | 1.49 | 62.0 | 200.0 | 3.23 | 91.0 | 100.0 | 1.10 | 147.0 | 300.0 | 2.04 | 299.0 | 800.0 | 2.68 | 368.0 | 1000.0 | 2.72 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2018 | 171 | 3 | 2782.0 | 6200.0 | 2.23 | 369.0 | 900.0 | 2.44 | 476.0 | 1300.0 | 2.73 | 347.0 | 900.0 | 2.59 | 134.0 | 200.0 | 1.49 | 116.0 | 100.0 | 0.86 | 183.0 | 200.0 | 1.09 | 108.0 | 200.0 | 1.85 | 142.0 | 100.0 | 0.70 | 96.0 | 200.0 | 2.08 | 145.0 | 200.0 | 1.38 | 294.0 | 800.0 | 2.72 | 372.0 | 1100.0 | 2.96 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2017 | 171 | 3 | 2815.0 | 6700.0 | 2.38 | 688.0 | 1700.0 | 2.47 | 210.0 | 800.0 | 3.81 | 225.0 | 600.0 | 2.67 | 156.0 | 300.0 | 1.92 | 127.0 | 300.0 | 2.36 | 138.0 | 100.0 | 0.72 | 137.0 | 200.0 | 1.46 | 134.0 | 100.0 | 0.75 | 100.0 | 200.0 | 2.00 | 142.0 | 200.0 | 1.41 | 338.0 | 900.0 | 2.66 | 420.0 | 1300.0 | 3.10 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2016 | 171 | 3 | 2764.0 | 6700.0 | 2.42 | 408.0 | 1200.0 | 2.94 | 340.0 | 1000.0 | 2.94 | 290.0 | 700.0 | 2.41 | 137.0 | 300.0 | 2.19 | 98.0 | 300.0 | 3.06 | 114.0 | 200.0 | 1.75 | 138.0 | 100.0 | 0.72 | 134.0 | 200.0 | 1.49 | 126.0 | 100.0 | 0.79 | 184.0 | 400.0 | 2.17 | 328.0 | 1000.0 | 3.05 | 467.0 | 1200.0 | 2.57 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2015 | 171 | 2 | 2272.0 | 5362.0 | 2.36 | 405.0 | 1100.0 | 2.72 | 417.0 | 1100.0 | 2.64 | 184.0 | 492.0 | 2.67 | 107.0 | 222.0 | 2.07 | 73.0 | 139.0 | 1.90 | 94.0 | 127.0 | 1.35 | 106.0 | 94.0 | 0.89 | 100.0 | 96.0 | 0.96 | 79.0 | 119.0 | 1.51 | 172.0 | 420.0 | 2.44 | 233.0 | 553.0 | 2.37 | 302.0 | 900.0 | 2.98 | |||||||||||||||||||||||||
1500 | Luft/Wasser | Stiebel Eltron LWZ 404 | 6.0 | 2014 | 171 | 2 | 1428.0 | 3200.0 | 2.24 | 123.0 | 300.0 | 2.44 | 169.0 | 200.0 | 1.18 | 112.0 | 100.0 | 0.89 | 90.0 | 200.0 | 2.22 | 79.0 | 100.0 | 1.27 | 149.0 | 200.0 | 1.34 | 306.0 | 900.0 | 2.94 | 400.0 | 1200.0 | 3.00 |
NR | 1500 |
Username | littleGSIdriver |
Einbaujahr der WP | 2013-06-01 |
PLZ des Wohnortes | 97320 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Stiebel Eltron LWZ 404 |
modulierend | Nein |
Leistung (0/35) | 6.0 kW |
berechneter Primärenergiebedarf | 37.3 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 43 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 171 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Die Stromverbrauchswerte beinhalten neben den Verbrauchswerten die zur Wärmegewinnung notwendig sind ( Wärmepumpe und Heizstab ) auch die Verbrauchswerte der Steuerung, Heizkreispumpe und Lüftung. Die Wärmerückgewinnungswerte der Lüftung sind in der Spalte WMZ nicht berücksichtigt. Im Sommer wurde bis 2018 mit Passivkühlung ( incl. Sommerkassette ) "gekühlt". Die Lüftung war bei hohen Außentemperaturen tagsüber aus, und lief Nachts mit 300m²/h, was die erhöhten Stromwerte in den Monaten Mai - August erklärt. |