Verbrauchsdaten fuer Anlage Nr. 1500
| Jahr | Pers. | GESAMT | Jan | Feb | Mar | Apr | Mai | Jun | Jul | Aug | Sep | Okt | Nov | Dez | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | Strom | WMZ | AZ | ||
| 2026 | 4 | 1018 | 2200 | 2.16 | 511 | 1300 | 2.54 | 317 | 600 | 1.89 | 190 | 300 | 1.58 | |||||||||||||||||||||||||||
| 2025 | 4 | 2517 | 6000 | 2.38 | 428 | 1100 | 2.57 | 396 | 1100 | 2.78 | 243 | 600 | 2.47 | 126 | 200 | 1.59 | 116 | 200 | 1.72 | 74 | 100 | 1.35 | 64 | 100 | 1.56 | 92 | 200 | 2.17 | 92 | 200 | 2.17 | 166 | 300 | 1.81 | 332 | 800 | 2.41 | 388 | 1100 | 2.84 |
| 2024 | 4 | 2322 | 5600 | 2.41 | 446 | 1200 | 2.69 | 235 | 600 | 2.55 | 193 | 400 | 2.07 | 150 | 300 | 2.00 | 96 | 200 | 2.08 | 80 | 200 | 2.50 | 102 | 200 | 1.96 | 60 | 100 | 1.67 | 102 | 200 | 1.96 | 134 | 200 | 1.49 | 311 | 800 | 2.57 | 413 | 1200 | 2.91 |
| 2023 | 4 | 2363 | 5400 | 2.29 | 357 | 900 | 2.52 | 338 | 900 | 2.66 | 264 | 500 | 1.89 | 213 | 300 | 1.41 | 105 | 200 | 1.90 | 80 | 200 | 2.50 | 77 | 100 | 1.30 | 88 | 200 | 2.27 | 61 | 100 | 1.64 | 127 | 200 | 1.57 | 298 | 800 | 2.68 | 355 | 1000 | 2.82 |
| 2022 | 4 | 2204 | 5300 | 2.40 | 394 | 1100 | 2.79 | 265 | 600 | 2.26 | 258 | 700 | 2.71 | 168 | 300 | 1.79 | 94 | 200 | 2.13 | 60 | 100 | 1.67 | 76 | 200 | 2.63 | 68 | 100 | 1.47 | 91 | 200 | 2.20 | 98 | 100 | 1.02 | 237 | 600 | 2.53 | 395 | 1100 | 2.78 |
| 2021 | 4 | 2578 | 6500 | 2.52 | 445 | 1300 | 2.92 | 344 | 900 | 2.62 | 269 | 700 | 2.60 | 181 | 300 | 1.66 | 136 | 400 | 2.94 | 75 | 100 | 1.33 | 75 | 200 | 2.67 | 72 | 100 | 1.39 | 84 | 200 | 2.38 | 199 | 300 | 1.51 | 321 | 900 | 2.80 | 377 | 1100 | 2.92 |
| 2020 | 4 | 2408 | 5500 | 2.28 | 371 | 1000 | 2.70 | 291 | 700 | 2.41 | 240 | 600 | 2.50 | 133 | 200 | 1.50 | 116 | 300 | 2.59 | 86 | 100 | 1.16 | 84 | 200 | 2.38 | 68 | 100 | 1.47 | 104 | 200 | 1.92 | 198 | 300 | 1.52 | 324 | 700 | 2.16 | 393 | 1100 | 2.80 |
| 2019 | 3 | 2349 | 5800 | 2.47 | 470 | 1400 | 2.98 | 314 | 800 | 2.55 | 242 | 600 | 2.48 | 129 | 200 | 1.55 | 102 | 200 | 1.96 | 58 | 100 | 1.72 | 67 | 100 | 1.49 | 62 | 200 | 3.23 | 91 | 100 | 1.10 | 147 | 300 | 2.04 | 299 | 800 | 2.68 | 368 | 1000 | 2.72 |
| 2018 | 3 | 2782 | 6200 | 2.23 | 369 | 900 | 2.44 | 476 | 1300 | 2.73 | 347 | 900 | 2.59 | 134 | 200 | 1.49 | 116 | 100 | 0.86 | 183 | 200 | 1.09 | 108 | 200 | 1.85 | 142 | 100 | 0.70 | 96 | 200 | 2.08 | 145 | 200 | 1.38 | 294 | 800 | 2.72 | 372 | 1100 | 2.96 |
| 2017 | 3 | 2815 | 6700 | 2.38 | 688 | 1700 | 2.47 | 210 | 800 | 3.81 | 225 | 600 | 2.67 | 156 | 300 | 1.92 | 127 | 300 | 2.36 | 138 | 100 | 0.72 | 137 | 200 | 1.46 | 134 | 100 | 0.75 | 100 | 200 | 2.00 | 142 | 200 | 1.41 | 338 | 900 | 2.66 | 420 | 1300 | 3.10 |
| 2016 | 3 | 2764 | 6700 | 2.42 | 408 | 1200 | 2.94 | 340 | 1000 | 2.94 | 290 | 700 | 2.41 | 137 | 300 | 2.19 | 98 | 300 | 3.06 | 114 | 200 | 1.75 | 138 | 100 | 0.72 | 134 | 200 | 1.49 | 126 | 100 | 0.79 | 184 | 400 | 2.17 | 328 | 1000 | 3.05 | 467 | 1200 | 2.57 |
| 2015 | 2 | 2272 | 5362 | 2.36 | 405 | 1100 | 2.72 | 417 | 1100 | 2.64 | 184 | 492 | 2.67 | 107 | 222 | 2.07 | 73 | 139 | 1.90 | 94 | 127 | 1.35 | 106 | 94 | 0.89 | 100 | 96 | 0.96 | 79 | 119 | 1.51 | 172 | 420 | 2.44 | 233 | 553 | 2.37 | 302 | 900 | 2.98 |
| 2014 | 2 | 1428 | 3200 | 2.24 | 123 | 300 | 2.44 | 169 | 200 | 1.18 | 112 | 100 | 0.89 | 90 | 200 | 2.22 | 79 | 100 | 1.27 | 149 | 200 | 1.34 | 306 | 900 | 2.94 | 400 | 1200 | 3.00 | ||||||||||||
Vollständige Anlagendetails
Allgemeine Daten
Anlagen Nr.
1500
Username
littleGSIdriver
Gebäude Daten
PLZ
97320
Heizfläche (m²)
171
Wärmeübertragung
FBH
Raumtemperatur (°C)
23.0
Lüftung
zenKWLWR
Endenergiebedarf (kWh/m²/anno)
37.3
berechnet nach Norm
EnEV2009
Wärmepumpe Daten
Hersteller / Typ
Stiebel Eltron LWZ 404
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
6.0
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Nein
Einbaudatum
2013-06-01
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
43
Legionellenschaltung
Nein
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Die Stromverbrauchswerte beinhalten neben den Verbrauchswerten die zur Wärmegewinnung notwendig sind ( Wärmepumpe und Heizstab ) auch die Verbrauchswerte der Steuerung, Heizkreispumpe und Lüftung. Die Wärmerückgewinnungswerte der Lüftung sind in der Spalte WMZ nicht berücksichtigt.
Im Sommer wurde bis 2018 mit Passivkühlung ( incl. Sommerkassette ) "gekühlt". Die Lüftung war bei hohen Außentemperaturen tagsüber aus, und lief Nachts mit 300m²/h, was die erhöhten Stromwerte in den Monaten Mai - August erklärt.
Links