Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2024 | 143 | 2 | 1246.6 | 732 | 570.8 | 357 | 273.3 | 154 | 248.1 | 140 | 131.1 | 73 | 4.3 | 0 | 4.0 | 0 | 4.6 | 0 | 5.2 | 0 | 5.2 | 8 | ||||||||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2023 | 143 | 2 | 2183.3 | 1289 | 428.6 | 273 | 418.9 | 239 | 306.7 | 192 | 195.0 | 125 | 30.7 | 15 | 4.2 | 0 | 7.3 | 2 | 4.3 | 0 | 4.3 | 0 | 78.8 | 43 | 303.7 | 172 | 400.8 | 228 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2022 | 143 | 2 | 2449.1 | 1424 | 464.5 | 270 | 372.1 | 207 | 327.5 | 185 | 224.5 | 125 | 19.1 | 8 | 9.0 | 3 | 2.3 | 0 | 6.3 | 0 | 48.3 | 25 | 96.2 | 54 | 328.3 | 222 | 551.0 | 325 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2021 | 143 | 2 | 2651.5 | 1521 | 528.5 | 305 | 463.3 | 271 | 331.8 | 197 | 278.5 | 159 | 74.4 | 40 | 4.2 | 0 | 11.5 | 4 | 4.0 | 0 | 11.0 | 4 | 190.4 | 115 | 323.6 | 182 | 430.3 | 244 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2020 | 143 | 4 | 2055.2 | 1156 | 447.4 | 257 | 344.3 | 190 | 297.2 | 168 | 96.7 | 53 | 38.9 | 20 | 4.2 | 0 | 9.0 | 3 | 4.3 | 1 | 10.0 | 3 | 134.8 | 74 | 281.9 | 159 | 386.5 | 228 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2019 | 143 | 4 | 2076.2 | 1190 | 522.0 | 307 | 317.1 | 192 | 227.4 | 127 | 106.0 | 58 | 76.6 | 52 | 13.9 | 5 | 0 | 0 | 11.3 | 2 | 11.3 | 4 | 109.2 | 60 | 295.6 | 166 | 385.8 | 217 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2018 | 143 | 4 | 2074.3 | 1206 | 355.2 | 210 | 531.9 | 314 | 388.2 | 244 | 53.4 | 28 | 4.3 | 0 | 7.8 | 2 | 4.4 | 0 | 7.4 | 2 | 20.8 | 9 | 112.1 | 61 | 268.4 | 152 | 320.4 | 184 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2017 | 143 | 4 | 2258.2 | 1323 | 621.0 | 387 | 363.7 | 213 | 213.1 | 127 | 169.2 | 105 | 35.3 | 18 | 4.3 | 0 | 4.3 | 0 | 4.3 | 0 | 12.7 | 12 | 123.0 | 66 | 297.5 | 166 | 409.8 | 229 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2016 | 143 | 5 | 2200.4 | 1237 | 469.8 | 268 | 351.2 | 195 | 298.4 | 167 | 141.6 | 80 | 19.9 | 11 | 0 | 0 | 0 | 0 | 0 | 0 | 4.1 | 1 | 153.5 | 84 | 339.6 | 191 | 422.3 | 240 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2015 | 143 | 5 | 2024.8 | 1167 | 396.3 | 223 | 443.2 | 261 | 312.8 | 176 | 167.8 | 94 | 21.8 | 26 | 0 | 0 | 0 | 0 | 0 | 0 | 21.6 | 12 | 197.0 | 110 | 238.6 | 138 | 225.7 | 127 | ||||||||||||||||||||||||||||||||||||||
1552 | Luft/DK | ACALOR NH56 | 7.2 | 2014 | 143 | 5 | 1881.1 | 1093 | 473.6 | 278 | 309.0 | 174 | 236.0 | 133 | 96.8 | 54 | 50.4 | 28 | 0 | 0 | 0 | 0 | 0 | 0 | 8.2 | 5 | 77.6 | 53 | 220.1 | 136 | 409.4 | 232 |
NR | 1552 |
Username | cal |
Einbaujahr der WP | 2001-01-05 |
PLZ des Wohnortes | 04249 |
Bauart | Luft/DK |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | ACALOR NH56 |
modulierend | Nein |
Leistung (0/35) | 7.2 kW |
berechneter Primärenergiebedarf | 55.0 kWh/m²/anno |
WW über WP | Nein |
WW Temperatur | 0 °C |
WW Legionellenschaltung | |
WW über WMZ erfasst | (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1800 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 0.0 °C |
Heizung max. Vorlauf Temp. | 0.0 °C |
Spreizung Heizkr. | 0.0 |
Heizflaeche | 143 m² |
Lüftung | zenKWLWR |
Personen | 5 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Im Fußbodenestrich direkt-kondensiernde LWP ACALOR NH56, elektrisch 1,8 kW, thermisch 4,6 kW bei A-15/W35. Reihenendhaus, mehrschalige Holzrahmenkonstruktion ohne Keller, Neubau 2000, getrennte Lüftung mit EWT + WRG, Warmwasser mit elektronischem Durchlauferhitzer. |