Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2024 | 160 | 2 | 2029.9 | 6699.0 | 744 | 3.30 | 634.0 | 2252.3 | 244 | 3.55 | 382.1 | 1271.7 | 139 | 3.33 | 331.5 | 1062.6 | 116 | 3.21 | 195.7 | 591.4 | 65 | 3.02 | 96.2 | 242.6 | 27 | 2.52 | 60.6 | 184.6 | 27 | 3.05 | 52.8 | 167.1 | 20 | 3.16 | 52.0 | 165.3 | 22 | 3.18 | 58.1 | 183.1 | 21 | 3.15 | 166.9 | 578.3 | 63 | 3.46 | ||||||||||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2023 | 160 | 3 | 3142.1 | 10858.6 | 1205 | 3.46 | 545.4 | 1952.6 | 215 | 3.58 | 443.6 | 1564.3 | 173 | 3.53 | 358.7 | 1265.0 | 140 | 3.53 | 290.7 | 981.9 | 108 | 3.38 | 106.8 | 350.0 | 39 | 3.28 | 70.3 | 225.6 | 25 | 3.21 | 58.9 | 186.3 | 21 | 3.16 | 65.7 | 196.2 | 23 | 2.99 | 62.4 | 183.8 | 26 | 2.95 | 119.6 | 386.9 | 44 | 3.23 | 470.6 | 1656.9 | 183 | 3.52 | 549.4 | 1909.1 | 208 | 3.47 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2022 | 160 | 3 | 3228.5 | 11083.6 | 1236 | 3.43 | 598.5 | 2103.4 | 236 | 3.51 | 449.3 | 1561.4 | 175 | 3.48 | 371.3 | 1244.3 | 140 | 3.35 | 297.3 | 992.9 | 111 | 3.34 | 85.9 | 268.0 | 31 | 3.12 | 61.7 | 192.3 | 22 | 3.12 | 68.0 | 213.1 | 24 | 3.13 | 59.5 | 190.3 | 21 | 3.20 | 122.4 | 399.4 | 44 | 3.26 | 114.4 | 363.6 | 40 | 3.18 | 389.3 | 1360.8 | 150 | 3.50 | 610.9 | 2194.1 | 242 | 3.59 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2021 | 160 | 3 | 3697.7 | 12557.8 | 1424 | 3.40 | 664.2 | 2316.6 | 262 | 3.49 | 471.6 | 1586.6 | 180 | 3.36 | 417.6 | 1406.3 | 160 | 3.37 | 339.3 | 1136.4 | 128 | 3.35 | 177.6 | 568.2 | 73 | 3.20 | 74.8 | 231.0 | 27 | 3.09 | 71.2 | 220.8 | 25 | 3.10 | 73.6 | 226.5 | 26 | 3.08 | 83.9 | 260.2 | 29 | 3.10 | 270.2 | 906.0 | 101 | 3.35 | 487.1 | 1697.2 | 189 | 3.48 | 566.6 | 2002.0 | 224 | 3.53 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2020 | 160 | 3 | 3144.7 | 10584.2 | 1195 | 3.37 | 544.6 | 1899.6 | 214 | 3.49 | 420.0 | 1454.5 | 164 | 3.46 | 384.4 | 1263.8 | 143 | 3.29 | 159.4 | 491.7 | 56 | 3.08 | 135.8 | 425.6 | 48 | 3.13 | 77.7 | 240.8 | 28 | 3.10 | 66.1 | 203.2 | 24 | 3.07 | 64.3 | 196.4 | 23 | 3.05 | 77.0 | 236.9 | 27 | 3.08 | 246.4 | 826.0 | 92 | 3.35 | 402.9 | 1374.0 | 154 | 3.41 | 566.1 | 1971.7 | 222 | 3.48 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2019 | 160 | 3 | 3196.1 | 10907.0 | 1243 | 3.41 | 644.8 | 2267.8 | 256 | 3.52 | 398.2 | 1370.8 | 155 | 3.44 | 371.0 | 1235.0 | 140 | 3.33 | 208.0 | 673.8 | 77 | 3.24 | 177.1 | 578.4 | 66 | 3.27 | 58.1 | 181.4 | 21 | 3.12 | 51.5 | 160.7 | 18 | 3.12 | 58.0 | 181.7 | 31 | 3.13 | 79.0 | 247.9 | 28 | 3.14 | 174.4 | 585.4 | 66 | 3.36 | 450.5 | 1572.7 | 177 | 3.49 | 525.5 | 1851.4 | 208 | 3.52 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2018 | 160 | 3 | 3234.8 | 11143.0 | 1260 | 3.44 | 545.9 | 1924.7 | 217 | 3.53 | 580.7 | 2051.6 | 232 | 3.53 | 491.3 | 1688.0 | 191 | 3.44 | 123.5 | 400.9 | 46 | 3.25 | 74.9 | 236.3 | 27 | 3.15 | 60.8 | 191.0 | 22 | 3.14 | 55.0 | 172.3 | 20 | 3.13 | 57.0 | 179.0 | 20 | 3.14 | 93.0 | 298.1 | 34 | 3.21 | 195.6 | 662.6 | 74 | 3.39 | 416.3 | 1446.7 | 163 | 3.48 | 540.8 | 1891.8 | 214 | 3.50 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2017 | 160 | 4 | 3294.3 | 11443.4 | 1295 | 3.47 | 697.9 | 2496.0 | 283 | 3.58 | 437.2 | 1553.4 | 175 | 3.55 | 325.3 | 1104.4 | 126 | 3.40 | 259.7 | 866.8 | 98 | 3.34 | 120.1 | 396.0 | 45 | 3.30 | 56.9 | 182.2 | 21 | 3.20 | 52.1 | 166.8 | 19 | 3.20 | 60.9 | 195.7 | 23 | 3.21 | 89.8 | 294.0 | 33 | 3.27 | 171.1 | 584.8 | 66 | 3.42 | 451.7 | 1590.4 | 179 | 3.52 | 571.6 | 2012.9 | 227 | 3.52 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2016 | 160 | 4 | 3320.5 | 11600.9 | 1314 | 3.49 | 554.7 | 1947.6 | 223 | 3.51 | 480.3 | 1720.0 | 194 | 3.58 | 436.0 | 1511.8 | 172 | 3.47 | 222.0 | 721.0 | 81 | 3.25 | 92.0 | 295.5 | 34 | 3.21 | 56.2 | 180.9 | 21 | 3.22 | 46.4 | 149.2 | 17 | 3.22 | 56.0 | 180.9 | 21 | 3.23 | 53.1 | 171.8 | 19 | 3.24 | 244.5 | 886.9 | 99 | 3.63 | 492.2 | 1750.2 | 197 | 3.56 | 587.1 | 2085.1 | 236 | 3.55 | ||||||||||||
1617 | Wasser/Wasser | Bartl WB 2 CF/W/HF | 10.1 | 2015 | 160 | 4 | 1219.4 | 4186.3 | 478 | 3.43 | 49.0 | 153.9 | 18 | 3.14 | 58.9 | 185.1 | 22 | 3.14 | 68.3 | 211.8 | 23 | 3.10 | 281.0 | 973.8 | 110 | 3.47 | 322.0 | 1127.8 | 130 | 3.50 | 440.2 | 1533.9 | 175 | 3.48 |
NR | 1617 |
Username | antidote |
Einbaujahr der WP | 2014-09-23 |
PLZ des Wohnortes | 99099 |
Bauart | Wasser/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Bartl WB 2 CF/W/HF |
modulierend | |
Leistung (0/35) | 10.1 kW |
berechneter Primärenergiebedarf | 50.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 48 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Förder- und Schluckbrunnen |
Tiefe | 40.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1950 Watt DB |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 250 Watt |
Stromzähler | intern > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 10.2 °C |
Heizung max. Vorlauf Temp. | 38.0 °C |
Spreizung Heizkr. | 7.0 |
Heizflaeche | 160 m² |
Lüftung | zenKWLWR |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | ab August 2017 Verbrauch WW-Zirkulationspumpe inkludiert |