Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1628 | Luft/Wasser | Tecalor TTL 10 AC | 6.5 | 2018 | 160 | 3 | 1532.0 | 2592.0 | 1.69 | 518.0 | 923.0 | 0 | 1.78 | 598.0 | 887.0 | 0 | 1.48 | 416.0 | 782.0 | 0 | 1.88 | |||||||||||||||||||||||||||||||||||||||||||||||||
1628 | Luft/Wasser | Tecalor TTL 10 AC | 6.5 | 2017 | 160 | 3 | 2858.0 | 8805.0 | 3.08 | 438.0 | 1659.0 | 0 | 3.79 | 288.0 | 1048.0 | 0 | 3.64 | 355.0 | 1336.0 | 0 | 3.76 | 331.0 | 1244.0 | 0 | 3.76 | 97.0 | 384.0 | 0 | 3.96 | 56.0 | 219.0 | 0 | 3.91 | 0 | 87.0 | 316.0 | 0 | 3.63 | 104.0 | 383.0 | 0 | 3.68 | 202.0 | 580.0 | 0 | 2.87 | 405.0 | 760.0 | 1.88 | 495.0 | 876.0 | 0 | 1.77 | |||||||||||||||||
1628 | Luft/Wasser | Tecalor TTL 10 AC | 6.5 | 2016 | 160 | 2 | 2810.6 | 8929.0 | 3.18 | 460.0 | 1532.0 | 0 | 3.33 | 372.0 | 1273.0 | 0 | 3.42 | 335.0 | 1180.0 | 0 | 3.52 | 197.0 | 776.0 | 0 | 3.94 | 88.6 | 349.0 | 0 | 3.94 | 46.0 | 173.0 | 0 | 3.76 | 39.0 | 145.0 | 0 | 3.72 | 40.0 | 141.0 | 0 | 3.53 | 56.0 | 194.0 | 0 | 3.46 | 235.0 | 692.0 | 0 | 2.94 | 229.0 | 815.0 | 0 | 3.56 | 713.0 | 1659.0 | 0 | 2.33 | |||||||||||||
1628 | Luft/Wasser | Tecalor TTL 10 AC | 6.5 | 2015 | 160 | 2 | 2913.5 | 10498.0 | 3.60 | 464.0 | 1436.0 | 0 | 3.09 | 462.0 | 1437.0 | 0 | 3.11 | 272.0 | 1185.0 | 0 | 4.36 | 152.0 | 527.0 | 0 | 3.47 | 90.0 | 332.0 | 0 | 3.69 | 89.0 | 374.0 | 0 | 4.20 | 45.0 | 167.0 | 0 | 3.71 | 41.0 | 163.0 | 0 | 3.98 | 140.0 | 611.0 | 0 | 4.36 | 240.0 | 928.0 | 0 | 3.87 | 290.2 | 1038.0 | 0 | 3.58 | 628.3 | 2300.0 | 0 | 3.66 | |||||||||||||
1628 | Luft/Wasser | Tecalor TTL 10 AC | 6.5 | 2014 | 160 | 2 | 1066.0 | 3972.0 | 3.73 | 47.0 | 173.0 | 3.68 | 46.0 | 189.0 | 4.11 | 48.0 | 251.0 | 5.23 | 50.0 | 207.0 | 4.14 | 150.0 | 630.0 | 4.20 | 277.0 | 1010.0 | 3.65 | 448.0 | 1512.0 | 3.38 |
NR | 1628 |
Username | easyhaus |
Einbaujahr der WP | 2014-06-01 |
PLZ des Wohnortes | 63110 |
Bauart | Luft/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Tecalor TTL 10 AC |
modulierend | |
Leistung (0/35) | 6.5 kW |
berechneter Primärenergiebedarf | 17.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 50 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Luft |
Tiefe | 0.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt gem. |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 23.0 °C |
Mittlere Wärmequellentemperatur | 32.0 °C |
Heizung max. Vorlauf Temp. | 35.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 160 m² |
Lüftung | Fenster |
Personen | 3 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | KfW70 (EnEV 2009) DHH-Neubau 2014 mit Unipor 36,5cm Mauerwerk, 30qm Keller mit Fbhzg., 3-Fach Verglasung, Süd-West Ausrichtung |