Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1660 | Sole/Wasser | Dimplex SIH9TE | 8.9 | 2017 | 184 | 2 | 3875.0 | * | 1491 | 705.0 | 0 | 262 | 520.0 | 0 | 260 | 440.0 | 0 | 227 | 366.0 | 0 | 119 | 224.0 | 0 | 32 | 64.0 | 0 | 16 | 64.0 | 0 | 16 | 65.0 | 0 | 16 | 127.0 | 0 | 32 | 264.0 | 0 | 80 | 442.0 | 0 | 175 | 594.0 | 0 | 256 | |||||||||||||||||||||||||
1660 | Sole/Wasser | Dimplex SIH9TE | 8.9 | 2016 | 184 | 2 | 3975.0 | * | 1613 | 737.0 | 319 | 605.0 | 255 | 558.0 | 235 | 324.0 | 116 | 196.0 | 73 | 83.0 | 56 | 70.0 | 23 | 76.0 | 25 | 70.0 | 23 | 266.0 | 125 | 425.0 | 118 | 565.0 | 245 | |||||||||||||||||||||||||||||||||||||
1660 | Sole/Wasser | Dimplex SIH9TE | 8.9 | 2015 | 184 | 2 | 3079.0 | * | 1237 | 545.0 | 245 | 535.0 | 235 | 467.0 | 197 | 338.0 | 134 | 140.0 | 50 | 126.0 | 57 | 44.0 | 15 | 118.0 | 27 | 118.0 | 27 | 291.0 | 121 | 357.0 | 129 | |||||||||||||||||||||||||||||||||||||||
1660 | Sole/Wasser | Dimplex SIH9TE | 8.9 | 2014 | 184 | 2 | 2564.0 | * | 983 | 570.0 | 210 | 313.0 | 114 | 215.0 | 78 | 113.0 | 34 | 67.0 | 22 | 63.0 | 21 | 114.0 | 41 | 221.0 | 81 | 375.0 | 156 | 513.0 | 226 |
NR | 1660 |
Username | Finsh99 |
Einbaujahr der WP | 2014-02-20 |
PLZ des Wohnortes | 1454 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Bi |
Hersteller Typ | Dimplex SIH9TE |
modulierend | |
Leistung (0/35) | 8.9 kW |
berechneter Primärenergiebedarf | 42.3 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 45 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Nein (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Grabenkollektor |
Tiefe | 1.5 m |
Fläche | 320 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 2002 Watt DB |
elektr. Verbrauch HP gem./DB | 20 Watt |
elektr. Verbrauch WQ P gem./DB | 60 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 22.0 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 26.0 °C |
Spreizung Heizkr. | 3.0 |
Heizflaeche | 184 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen |