Verbrauchsdaten fuer Anlage Nr. 1678

JahrPers. GESAMT JanFebMarAprMaiJun JulAugSepOktNovDez
StromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZStromWMZAZ
2021 4 1908 10151 5.32 53829075.4041319664.7633217215.1820917218.23963783.94592544.31421854.40502114.22542043.781156045.25
2020 4 2063 9279 4.50 36212693.5127410964.0028914555.031003903.90752933.91582414.16622764.45492104.29512003.92873203.6827014705.4438620595.33
2019 4 507 1708 3.37 50717083.37
2018 4 2427 8864 3.65 39914493.6354218623.4437813283.51933473.73662573.89502164.32662934.44562434.34542153.981033773.662429013.7237813763.64
2017 3 2691 10302 3.83 67225333.7739217054.352459203.762158063.75692703.91592494.22512164.24522154.13602193.65792753.4834712943.7345016003.56
2016 3 2369 10830 4.57 44319794.4736217154.7428312744.501708034.72762993.93512114.14532294.32522224.27552224.041205364.4728413574.7842019834.72
2015 3 733 3311 4.52 672724.061375504.0123010284.4729914614.89

Vollständige Anlagendetails

Allgemeine Daten
Anlagen Nr.
1678
Username
keppler
Gebäude Daten
PLZ
75392
Heizfläche (m²)
169
Wärmeübertragung
FBH
Raumtemperatur (°C)
22.0
Lüftung
dezKWLWR
Endenergiebedarf (kWh/m²/anno)
50.1
berechnet nach Norm
EnEV2009
Wärmepumpe Daten
Hersteller / Typ
Kermi x-change WPLI 16
Bauart
Luft/Wasser
Heizleistung (kW) (0/35 2/35)
12.9
Betriebsart Mono/Bi/Tri-valent
Bi
Modulierend
Einbaudatum
2014-12-14
Wärmepumpe Leistungsaufnahme (W)
Umwälzpumpe Leistungsaufnahme (W)
Wärme Quelle & Senke
Quelle
Luft
Tiefe (m)
Fläche (m²)
max. Vorlauftemperatur (°C)
Spreizung Heizkreise (°K)
Quellenpumpe Leistungsaufnahme (W)
RGK Helfer
Nein
RGK Erfahrung
Warmwasser
über WP erzeugt
Ja
über WMZ erfasst
Ja
Temp (°C)
47
Legionellenschaltung
Nein
Zähler
Stromzähler
Stromzähler erfasst
Wärmemengenzähler
Informationen
Bemerkungen
Links

Standort