Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2020 | 160 | 2 | 999.0 | 5067.0 | 666 | 5.07 | 330.0 | 1664.0 | 220 | 5.04 | 280.5 | 1418.5 | 187 | 5.06 | 231.0 | 1183.0 | 154 | 5.12 | 115.5 | 591.5 | 77 | 5.12 | 27.0 | 138.0 | 18 | 5.11 | 15.0 | 72.0 | 10 | 4.80 | ||||||||||||||||||||||||||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2019 | 160 | 2 | 1737.0 | 8954.5 | 1158 | 5.16 | 322.5 | 1648.5 | 215 | 5.11 | 232.5 | 1193.5 | 155 | 5.13 | 240.0 | 1246.0 | 160 | 5.19 | 82.5 | 437.5 | 55 | 5.30 | 40.5 | 210.5 | 27 | 5.20 | 12.0 | 59.0 | 8 | 4.92 | 13.5 | 67.5 | 9 | 5.00 | 13.5 | 66.0 | 9 | 4.89 | 9.0 | 43.0 | 6 | 4.78 | 163.5 | 876.5 | 109 | 5.36 | 268.5 | 1388.5 | 179 | 5.17 | 339.0 | 1718.0 | 226 | 5.07 | ||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2018 | 160 | 2 | 1586.5 | 8172.5 | 1057 | 5.15 | 294.0 | 1508.0 | 196 | 5.13 | 300.0 | 1524.0 | 200 | 5.08 | 300.0 | 1519.0 | 200 | 5.06 | 81.0 | 418.0 | 54 | 5.16 | 14.0 | 65.0 | 9 | 4.64 | 11.0 | 49.0 | 7 | 4.45 | 10.5 | 54.5 | 7 | 5.19 | 10.5 | 52.5 | 7 | 5.00 | 12.0 | 58.0 | 8 | 4.83 | 60.0 | 334.0 | 40 | 5.57 | 214.5 | 1135.5 | 143 | 5.29 | 279.0 | 1455.0 | 186 | 5.22 | ||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2017 | 160 | 2 | 1651.5 | 8569.5 | 1101 | 5.19 | 334.5 | 1712.5 | 223 | 5.12 | 279.0 | 1419.0 | 186 | 5.09 | 201.0 | 1040.0 | 134 | 5.17 | 138.0 | 728.0 | 92 | 5.28 | 52.5 | 275.5 | 35 | 5.25 | 12.0 | 58.0 | 8 | 4.83 | 12.0 | 57.0 | 8 | 4.75 | 12.0 | 57.0 | 8 | 4.75 | 13.5 | 63.5 | 9 | 4.70 | 99.0 | 544.0 | 66 | 5.49 | 216.0 | 1156.0 | 144 | 5.35 | 282.0 | 1459.0 | 188 | 5.17 | ||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2016 | 160 | 2 | 1531.5 | 7992.0 | 1021 | 5.22 | 327.0 | 1685.0 | 218 | 5.15 | 205.5 | 1065.5 | 137 | 5.18 | 247.5 | 1279.5 | 165 | 5.17 | 129.0 | 687.0 | 86 | 5.33 | 25.5 | 132.5 | 17 | 5.20 | 10.5 | 50.5 | 7 | 4.81 | 13.5 | 64.0 | 9 | 4.74 | 10.5 | 51.5 | 7 | 4.90 | 10.5 | 52.5 | 7 | 5.00 | 88.5 | 490.5 | 59 | 5.54 | 184.5 | 981.5 | 123 | 5.32 | 279.0 | 1452.0 | 186 | 5.20 | ||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2015 | 160 | 2 | 1424.0 | 7402.0 | 949 | 5.20 | 324.0 | 1637.0 | 216 | 5.05 | 267.0 | 1344.0 | 178 | 5.03 | 198.0 | 1027.0 | 132 | 5.19 | 102.0 | 542.0 | 68 | 5.31 | 63.0 | 345.0 | 42 | 5.48 | 15.0 | 75.0 | 10 | 5.00 | 9.0 | 46.0 | 6 | 5.11 | 9.0 | 44.0 | 6 | 4.89 | 11.0 | 48.0 | 7 | 4.36 | 81.0 | 443.0 | 54 | 5.47 | 147.0 | 799.0 | 98 | 5.44 | 198.0 | 1052.0 | 132 | 5.31 | ||||||||||||
1686 | Sole/Wasser | Vaillant geoTherm plus 62/3 | 6.1 | 2014 | 160 | 2 | 291.0 | 1482.0 | 194 | 5.09 | 291.0 | 1482.0 | 194 | 5.09 |
NR | 1686 |
Username | HomerRL |
Einbaujahr der WP | 2014-01-30 |
PLZ des Wohnortes | 19061 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant geoTherm plus 62/3 |
modulierend | |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 47.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 44 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 65.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1300 Watt DB |
elektr. Verbrauch HP gem./DB | 75 Watt |
elektr. Verbrauch WQ P gem./DB | 75 Watt |
Stromzähler | > erfasst: |
WMZ | |
Mittlere Raumtemp. | 21.0 °C |
Mittlere Wärmequellentemperatur | 6.0 °C |
Heizung max. Vorlauf Temp. | 26.0 °C |
Spreizung Heizkr. | 6.5 |
Heizflaeche | 160 m² |
Lüftung | zenKWLWR |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Verbrauch mit 1,5 kW pro Kompressorstunde angesetzt! HK 0.10, RT 21°C, EI 120 min (ab 2016 RT 22°C und max. VL auf 25°C begrenzt), Abschaltung bei 15°C AT, WW 44/35°C, Sommermonate Heizung manuell deaktiviert. Kein Puffer oder ERR. Hydraulischer Abgleich frei Schnauze. Tägliche Erfassung von Laufzeit, Starts und des integrierten Ertragzählers der Vaillant. Da die Tabellenformel hier nicht den Verbrauch zum Ertrag addiert und dann durch den Verbrauch dividiert, wurde dies bei der Eingabe eigenständig korrigiert. Bsp. Nov. 2015: Ertrag 652 kWh, Laufzeit 98h, Starts 212 --> 98h x 1,5 kW rund 147 kWh Verbrauch --> (652 + 147)/147 rund 5,4 AZ. Ab Winter 2016/2017 neue Einstellungen: HK 0,1, RT 23°C und max. VLsoll auf 26°C begrenzt, um in WZ,EZ und Bädern die 22°C real zu erreichen. |