Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2020 | 210 | 4 | 2407.0 | 12967.0 | 1593 | 5.39 | 408.0 | 2196.0 | 278 | 5.38 | 334.0 | 1761.0 | 220 | 5.27 | 319.0 | 1739.0 | 217 | 5.45 | 108.0 | 571.0 | 70 | 5.29 | 112.0 | 609.0 | 71 | 5.44 | 79.0 | 405.0 | 47 | 5.13 | 41.0 | 171.0 | 20 | 4.17 | 33.0 | 129.0 | 15 | 3.91 | 71.0 | 356.0 | 41 | 5.01 | 220.0 | 1225.0 | 144 | 5.57 | 290.0 | 1627.0 | 198 | 5.61 | 392.0 | 2178.0 | 272 | 5.56 | ||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2019 | 210 | 4 | 2681.9 | 13994.0 | 3538 | 5.22 | 533.9 | 2818.0 | 368 | 5.28 | 326.0 | 1709.0 | 2016 | 5.24 | 294.0 | 1590.0 | 197 | 5.41 | 209.0 | 1112.0 | 136 | 5.32 | 198.0 | 1019.0 | 122 | 5.15 | 61.0 | 219.0 | 26 | 3.59 | 58.0 | 203.0 | 24 | 3.50 | 39.0 | 108.0 | 11 | 2.77 | 70.0 | 317.0 | 38 | 4.53 | 155.0 | 844.0 | 98 | 5.45 | 346.0 | 1913.0 | 235 | 5.53 | 392.0 | 2142.0 | 267 | 5.46 | ||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2018 | 210 | 4 | 2559.0 | 13345.0 | 1845 | 5.21 | 426.0 | 2260.0 | 452 | 5.31 | 426.0 | 2403.0 | 314 | 5.64 | 380.0 | 2011.0 | 259 | 5.29 | 108.0 | 522.0 | 64 | 4.83 | 96.0 | 444.0 | 53 | 4.63 | 58.0 | 218.0 | 26 | 3.76 | 55.0 | 202.0 | 24 | 3.67 | 41.0 | 134.0 | 15 | 3.27 | 58.0 | 253.0 | 30 | 4.36 | 161.0 | 850.0 | 101 | 5.28 | 317.0 | 1720.0 | 212 | 5.43 | 433.0 | 2328.0 | 295 | 5.38 | ||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2017 | 210 | 4 | 2867.4 | 14887.4 | 1882 | 5.19 | 579.0 | 3033.0 | 403 | 5.24 | 359.0 | 1905.0 | 246 | 5.31 | 256.4 | 1365.4 | 171 | 5.33 | 242.0 | 1295.0 | 161 | 5.35 | 127.0 | 626.0 | 76 | 4.93 | 60.0 | 213.0 | 25 | 3.55 | 65.0 | 219.0 | 25 | 3.37 | 41.0 | 134.0 | 15 | 3.27 | 107.0 | 540.0 | 63 | 5.05 | 178.0 | 958.0 | 114 | 5.38 | 391.0 | 2130.0 | 266 | 5.45 | 462.0 | 2469.0 | 317 | 5.34 | ||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2016 | 210 | 4 | 3041.0 | 15610.9 | 1940 | 5.13 | 463.0 | 2499.0 | 320 | 5.40 | 415.0 | 2240.0 | 286 | 5.40 | 392.0 | 2108.5 | 270 | 5.38 | 243.0 | 1312.0 | 162 | 5.40 | 130.0 | 652.0 | 79 | 5.02 | 64.0 | 233.0 | 26 | 3.64 | 44.0 | 138.0 | 15 | 3.14 | 138.0 | 206.0 | 10 | 1.49 | 69.0 | 312.0 | 35 | 4.52 | 253.0 | 1411.0 | 167 | 5.58 | 377.0 | 2067.0 | 258 | 5.48 | 453.0 | 2432.4 | 312 | 5.37 | ||||||||||||
1691 | Sole/Wasser | Vaillant - VWS 61/3 | 6.1 | 2015 | 210 | 4 | 556.0 | 3106.0 | 244 | 5.59 | 190.0 | 1123.0 | 5.91 | 366.0 | 1983.0 | 244 | 5.42 |
NR | 1691 |
Username | Roland.Legis |
Einbaujahr | 2014-08-26 |
PLZ des Wohnortes | 73272 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant - VWS 61/3 |
modulierend | |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 42.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 42 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | 2 Erdbohrungen |
Tiefe | 80.0 m |
Fläche | 0 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 0 Watt DB |
elektr. Verbrauch HP gem./DB | 0 Watt |
elektr. Verbrauch WQ P gem./DB | 0 Watt |
Mittlere Raumtemp. | 23 °C |
Mittlere Wärmequellentemperatur | 7.2 °C |
Heizung max. Vorlauf Temp. | 30.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 210 m² |
Lüftung | zenKWLWR |
Personen | 4 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | Legionelleschaltung seit dem 01.01.2016 komplett deaktiviert. WW wird seit Sommer 2020 mit Google Home bedarfsgerecht gestartet. WW Temperatur je nach Bedarf 35-45°C. Heizkurve wird durch Manipulieren des Außensensors verändert wenn Wärmebedarf (durch starke Sonneneinstrahlung) gedeckt ist, oder wenn es mal zu kalt ist. Realisiert habe ich das über eine mit Homematic steuerbare Widerstandsschaltung. |