Weiterhin alles Gute Michael Schumacher!
Anlage NR |
Bauart | Hersteller Typ |
Leistung kW |
Jahr | Heiz- fläche qm |
Personen | gesamt kWh Strom |
gesamt kWh WMZ |
gesamt BStd |
AZ |
JAN Strom kWh |
JAN WMZ kWh |
JAN BStd |
JAN AZ |
FEB Strom kWh |
FEB WMZ kWh |
FEB BStd |
FEB AZ |
MAE Strom kWh |
MAE WMZ kWh |
MAE BStd |
MAE AZ |
APR Strom kWh |
APR WMZ kWh |
APR BStd |
APR AZ |
MAI Strom kWh |
MAI WMZ kWh |
MAI BStd |
MAI AZ |
JUN Strom kWh |
JUN WMZ kWh |
JUN BStd |
JUN AZ |
JUL Strom kWh |
JUL WMZ kWh |
JUL BStd |
JUL AZ |
AUG Strom kWh |
AUG WMZ kWh |
AUG BStd |
AUG AZ |
SEP Strom kWh |
SEP WMZ kWh |
SEP BStd |
SEP AZ |
OKT Strom kWh |
OKT WMZ kWh |
OKT BStd |
OKT AZ |
NOV Strom kWh |
NOV WMZ kWh |
NOV BStd |
NOV AZ |
DEZ Strom kWh |
DEZ WMZ kWh |
DEZ BStd |
DEZ AZ |
||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2024 | 155 | 2 | 1099.8 | 5393.8 | 568 | 4.90 | 525.3 | 2539.3 | 345 | 4.83 | 335.3 | 1630.3 | 223 | 4.86 | 239.2 | 1224.2 | 5.12 | |||||||||||||||||||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2023 | 155 | 2 | 1994.5 | 9976.9 | 1288 | 5.00 | 432.7 | 2152.0 | 285 | 4.97 | 409.0 | 1951.0 | 268 | 4.77 | 287.0 | 1388.0 | 188 | 4.84 | 136.0 | 688.0 | 90 | 5.06 | 49.4 | 283.4 | 28 | 5.74 | 285.2 | 1514.2 | 174 | 5.31 | 395.2 | 2000.3 | 255 | 5.06 | ||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2022 | 155 | 2 | 1683.5 | 8182.0 | 1070 | 4.86 | 527.5 | 2493.0 | 338 | 4.73 | 389.0 | 1812.0 | 251 | 4.66 | 203.0 | 938.0 | 126 | 4.62 | 105.0 | 507.0 | 68 | 4.83 | 2.0 | 7.0 | 1 | 3.50 | 192.0 | 1063.0 | 116 | 5.54 | 265.0 | 1362.0 | 170 | 5.14 | ||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2021 | 155 | 2 | 2410.1 | 11701.5 | 1542 | 4.86 | 591.5 | 2782.5 | 380 | 4.70 | 458.2 | 2096.0 | 296 | 4.57 | 364.0 | 1714.0 | 236 | 4.71 | 142.8 | 689.0 | 92 | 4.82 | 147.6 | 814.0 | 87 | 5.51 | 372.7 | 1950.0 | 235 | 5.23 | 333.3 | 1656.0 | 216 | 4.97 | ||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2020 | 155 | 2 | 921.3 | 4869.5 | 623 | 5.29 | 122.1 | 715.0 | 88 | 5.86 | 320.3 | 1761.0 | 216 | 5.50 | 478.9 | 2393.5 | 319 | 5.00 | ||||||||||||||||||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2016 | 155 | 2 | 1446.0 | 6084.0 | 687 | 4.21 | 517.0 | 2297.0 | 259 | 4.44 | 486.0 | 1997.0 | 229 | 4.11 | 416.0 | 1680.0 | 188 | 4.04 | 27.0 | 110.0 | 11 | 4.07 | ||||||||||||||||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2015 | 155 | 3 | 1860.6 | 8531.0 | 916 | 4.59 | 530.9 | 2404.9 | 267 | 4.53 | 501.7 | 2188.7 | 261 | 4.36 | 226.9 | 1025.9 | 119 | 4.52 | 59.6 | 278.6 | 30 | 4.67 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8.0 | 2.0 | 0.25 | 111.0 | 592.0 | 44 | 5.33 | 255.8 | 1258.9 | 117 | 4.92 | 166.7 | 780.0 | 78 | 4.68 | |||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2014 | 155 | 3 | 1448.3 | 6722.4 | 700 | 4.64 | 488.9 | 2181.0 | 244 | 4.46 | 399.3 | 1759.3 | 203 | 4.41 | 111.1 | 483.1 | 46 | 4.35 | 6.6 | 26.6 | 3 | 4.03 | 2.6 | 9.6 | 1 | 3.69 | 0 | 0 | 0 | 0 | 0 | 0 | 0.7 | 1.7 | 2.43 | 68.5 | 372.5 | 30 | 5.44 | 272.9 | 1416.9 | 126 | 5.19 | 97.7 | 471.7 | 47 | 4.83 | |||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2013 | 155 | 4 | 2714.2 | 11988.2 | 1343 | 4.42 | 570.4 | 2496.4 | 290 | 4.38 | 608.9 | 2542.9 | 309 | 4.18 | 495.9 | 2103.9 | 255 | 4.24 | 190.5 | 787.5 | 95 | 4.13 | 2.9 | 6.9 | 1 | 2.38 | 0 | 0 | 0 | 0 | 0 | 0 | 6.9 | 18.9 | 3 | 2.74 | 79.2 | 415.2 | 29 | 5.24 | 313.9 | 1565.9 | 144 | 4.99 | 445.6 | 2050.6 | 217 | 4.60 | ||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2012 | 155 | 4 | 2014.9 | 8726.2 | 920 | 4.33 | 504.0 | 2178.0 | 244 | 4.32 | 715.0 | 2916.0 | 353 | 4.08 | 141.0 | 571.0 | 66 | 4.05 | 0 | 0 | 0 | 0 | 1.0 | 3.0 | 3.00 | 0 | 0 | 0 | 0 | 0 | 0 | 0.9 | 3.2 | 3.56 | 152.0 | 762.0 | 5.01 | 501.0 | 2293.0 | 257 | 4.58 | |||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2011 | 155 | 4 | 1920.6 | 8466.8 | 4.41 | 569.0 | 2406.0 | 4.23 | 521.0 | 2188.0 | 4.20 | 172.1 | 717.1 | 4.17 | 4.7 | 12.7 | 2.70 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 28.3 | 140.0 | 4.95 | 215.5 | 1101.0 | 5.11 | 410.0 | 1902.0 | 4.64 | ||||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2010 | 155 | 4 | 2086.9 | 9231.0 | 4.42 | 566.0 | 2466.0 | 4.36 | 463.0 | 1980.0 | 4.28 | 103.7 | 437.0 | 4.21 | 5.5 | 15.0 | 2.73 | 12.0 | 35.0 | 2.92 | 2.9 | 9.0 | 3.10 | 0.5 | 1.7 | 3.40 | 6.7 | 19.7 | 2.94 | 11.0 | 31.0 | 2.82 | 16.1 | 53.5 | 3.32 | 229.8 | 1218.4 | 5.30 | 669.7 | 2964.7 | 4.43 | |||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2009 | 155 | 4 | 1913.6 | 8493.3 | 4.44 | 669.5 | 2883.5 | 4.31 | 459.0 | 1924.0 | 4.19 | 176.7 | 759.0 | 4.30 | 1.6 | 5.0 | 3.13 | 0 | 0 | 0 | 0 | 0.5 | 1.5 | 3.00 | 0 | 0 | 2.0 | 6.0 | 3.00 | 20.3 | 71.3 | 3.51 | 173.0 | 885.0 | 5.12 | 411.0 | 1958.0 | 4.76 | ||||||||||||||||||||||||||||
17 | Sole/Wasser | Vaillant VWS82/2 | 6.1 | 2008 | 155 | 4 | 621.0 | 2792.0 | 248 | 4.50 | 3.0 | 11.0 | 3.67 | 29.0 | 117.0 | 4.03 | 137.0 | 621.0 | 4.53 | 452.0 | 2043.0 | 248 | 4.52 |
NR | 17 |
Username | NoCOP |
Einbaujahr der WP | 2020-08-15 |
PLZ des Wohnortes | 97400 |
Bauart | Sole/Wasser |
Mono-Bi-Tri Valent | Mono |
Hersteller Typ | Vaillant VWS82/2 |
modulierend | Nein |
Leistung (0/35) | 6.1 kW |
berechneter Primärenergiebedarf | 0.0 kWh/m²/anno |
WW über WP | Ja |
WW Temperatur | 43 °C |
WW Legionellenschaltung | Nein |
WW über WMZ erfasst | Ja (wenn der Wert auf Nein steht, werden 70 kWh/mon/pers auf den WMZ addiert) |
Quelle | Flachkollektoren |
Tiefe | 1.6 m |
Fläche | 280 m² |
Heizungsart | FBH |
elektr. Verbrauch WP ohne NA gem./DB | 1400 Watt DB |
elektr. Verbrauch HP gem./DB | 40 Watt |
elektr. Verbrauch WQ P gem./DB | 50 Watt |
Stromzähler | extern_geeicht > erfasst: Kompressor,Steuerung,Pumpen |
WMZ | intern |
Mittlere Raumtemp. | 21.5 °C |
Mittlere Wärmequellentemperatur | 3.0 °C |
Heizung max. Vorlauf Temp. | 33.0 °C |
Spreizung Heizkr. | 5.0 |
Heizflaeche | 155 m² |
Lüftung | Fenster |
Personen | 2 |
Grabenkollektor Helfer | Nein |
Grabenkollektor Erfahrung | |
Bemerkungen | HTD Frühere Vaillant VWS 82/2 aus 2008 seit 8/2020 umgebaut auf gebrauchte VWS 63/3! Erdkollektor 6 x 200m, kein Pufferspeicher, ERR etc. FBH im EG, HeizKörper(3-lagig) im DG werden mit FBH-Temperatur betrieben |